Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
|
|
tom Vol. 51, No. 3
109--116
EN
The author presents the results of research on the use of artificial neural networks in predicting voter turnout. He describes the principles of operation of artificial neural networks, as well as detailed results of two machine learning methods used to predict voter turnout. The research resulted in creation of a functional model that allows for prediction of voter turnout results with a considerable degree of accuracy. The entire research process was carried out using the cartographic research method.
|
|
tom T. 50, nr 2
50--55
PL
W artykule zaprezentowano procedurę obliczania miesięcznych zysków ciepła od nasłonecznienia według nowej normy PN-EN ISO 52016-1:2017-09. Jako dane wejściowe wykorzystuje ona wartości napromieniowania na dowolnie zorientowaną powierzchnię pochyloną obliczane według metody podanej w normie PN-EN ISO 52010-1:2017-09. Obecnie obliczenia zysków słonecznych są wykonywane na podstawie danych promieniowania słonecznego z plików typowych lat meteorologicznych dostępnych na stronie internetowej Ministerstwa Infrastruktury i Rozwoju. W celach porównawczych przeprowadzono obliczenia tych zysków na przykładzie jednorodzinnego i wielorodzinnego budynku mieszkalnego wg nowej metody oraz danych z typowych lat meteorologicznych. Analizę wykonano przyjmując kolejno lokalizację budynku w Białymstoku, Łodzi, Rzeszowie, Szczecinie oraz Wrocławiu. Dla wszystkich lokalizacji uzyskano spadek wartości zysków słonecznych obliczonych za pomocą nowej metody. Dla pierwszego budynku wyniósł on od 28,2% do 36,6%, zaś dla drugiego od 31,4% do 42,1%.
EN
The article presents a procedure for solar heat gains calculation according to the new PN-EN ISO 52016-1:2017-09 standard. As input data it uses values of irradiation on any oriented sloped surface calculated according to the method given in PN-EN ISO 52010-1:2017-09. Currently, calcula- tions of solar heat gains are performed on the basis of solar radiation data from files with typical meteorological years available on the website of the Ministry of Infrastructure and Development. For comparative purposes, calculations of so- lar gains were performed for an exemplary single-family and multi-family building based on a new method and meteorological data from typical meteorological years. The analysis was carried out successively for Białystok, Łódź, Rzeszów, Szczecin and Wrocław. A decrease in the value of solar gains calculated using the new method was obtained for all locations. For the first building it ranged from 28.2% to 36.6%, and for the second one from 31.4% to 42.1%.
|
|
tom T. 50, nr 7
253--256
PL
W artykule przedstawiono i omówiono błędy zauważone w normie PN-EN ISO 52010-1:2017-09. Do oceny ich wpływu na wynikową wartość natężenia promieniowania słonecznego wykonano obliczenia w pięciu lokalizacjach: Białymstoku, Łodzi, Rzeszowie, Szczecinie i Wrocławiu. Przedmiotem analizy była powierzchnia pionowa zorientowana w kierunkach N, S, E i W, przy czym obliczenia wykonano zgodnie z algorytmem opisanym w normie. Wartości referencyjne uzyskano z oryginalnego modelu Pereza, który został użyty także w normie. Zanotowano rozbieżności w wartościach godzinowych natężenia promieniowania rozproszonego oraz miesięcznych napromieniowania rozproszonego wyznaczonych tymi dwoma sposobami. Następnie, na przykładzie dwóch budynków mieszkalnych, obliczono roczne QH oraz jednostkowe EA zapotrzebowanie na ciepło do ogrzewania. W budynku jednorodzinnym nie zanotowano istotnych różnic między normą a oryginalnym modelem. Natomiast w budynku wielorodzinnym zmiany wskaźnika EA wyniosły od -0,2 kWh/m2 do +0,5 kWh/m2. Przedstawione wnioski wskazują na koniczność poprawienia w normie wskazanych błędów.
EN
The article presents and discusses errors noticed in PN-EN ISO 52010-1:2017-09. To assess their impact on the resulting values of solar irradiance, calculations were carried out for five locations: Białystok, Łódź, Rzeszów, Szczecin and Wrocław. The analysis was performed for the vertical surface oriented in the N, S, E and W directions using the algorithm presented in the standard. The reference values were obtained from the original Perez model, also implemented in the standard. Discrepancies in the hourly values of diffuse solar irradiance and monthly irradiation determined using these two methods were reported. Next, for two example residential buildings, annual QH and unit EA energy demand for heating was calculated using both methods. There were no significant differences in the single- family building. In the case of a multi-family building, a change in the EA index ranged from -0.2 kWh/m2 to +0.5 kWh/m2. The conclusions presented indicate the need to correct in the standard presented errors.
|
|
tom Nr 4
31--34
PL
W artykule przedstawiono projekt płaszczyznowego systemu ogrzewania podłogowego wodnego według normy PN-EN 1264 w wybranym pomieszczeniu domu jednorodzinnego. Ze względu na ograniczenia narzucone przez wytyczne projektowe konieczny okazał się podział systemu na dwa mniejsze obiegi. Sprawdzono warunki projektowe i przedstawiono rozmieszczenie rur grzejnych. Czasochłonność metody przemawia za stosowaniem w praktyce metod uproszczonych zalecanych przez producentów konkretnych rozwiązań lub komputerowych narzędzi projektowych.
EN
The article presents a design of an underfloor water heating system according to the PN-EN 1264 standard in a selected room in a single-family house. Due to the restrictions imposed by the design guidelines, it was necessary to divide the system into two smaller circuits. Design conditions were checked and the location of heating pipes was presented. Time-consuming nature of this method implies the use of simplified methods recommended by manufacturers of specific solutions or computer design tools.
EN
The vast majority of passenger rail transport in Poland is carried out by vehicles powered by electric traction. In case when a train needs to pass through a non-electrified section of the line, it is necessary to use an electric traction-independent vehicle, which, translated into the current situation, means using a vehicle with an internal combustion engine. The authors propose using a dual-drive 111DE locomotive for passenger rail transport, which can move on electrified and non-electrified railway lines. The article also presents data on the railway infrastructure and statistics on passenger rail transport in Poland. Considerations and justification for the use of a dual-drive vehicle are presented.
PL
Publikacja zawiera ocenę warunków geotermalnych, koncepcje zamiany obecnego zasilania ciepłowni przez spalanie węgla na geotermalny system sprężarkowych pomp ciepła. Oprócz analizy technicznej wykonalności została przeprowadzona analiza ekonomiczna. Przedstawiono warunki i potencjalne zbiorniki geotermalne: województwa, powiatu, gminy i miasta Oława. Zbiorniki: Triasu oraz Permu Dolnego zostały przeanalizowane pod względem ich głębokości, temperatury, przewodności hydraulicznej i potencjalnej wydajności ujęć. Na podstawie danych źródłowych (MZEC) uzyskano informacje o potencjalnej produkcji ciepła po przeprowadzonej modernizacji.
EN
The paper presents an assessment of the geothermal conditions and concept for replacing the current coal-fired heating plant with a geothermal compressor heat pump system. In addition to a technical feasibility analysis, an economic analysis was carried out. The conditions and potential geothermal reservoirs of the province, County and Oława municipality are presented. Reservoirs of the Triassic and Lower Permian were analyzed in terms of their depth, temperature, hydraulic conductivity and potential intake capacity. Based on historical data, potential heat production after modernization was obtained.
EN
The use of dual-drive rolling stock is a relatively new solution in the railway market. Vehicles with such type of powertrain are more versatile because it combines the advantages of using diesel vehicles and electric vehicles that consume energy from overhead electric traction. The concept of using such vehicles is highly innovative and has many advantages. However, the design and construction process is more complicated and requires more work than in the case of conventional systems. This article presents the methodology and process of selecting an engine-generator set for a dual-drive locomotive. Indicators and procedures crucial in the process of selecting a dual-drive system for a locomotive, were described and evaluated. All the above mentioned in the work were used during the real design process of a fully Polish locomotive with both diesel and electric drives. The locomotive in Diesel mode was to have an output power of circa 1560 kW for cargo transport. Calculations for the locomotive's power balance are included, showing power losses in the system and for locomotive's own needs. It has been shown that in cargo transport 77% of the maximum engine power is used as tractive power, and in passenger transport 58.6%.
PL
Artykuł przedstawia ocenę potencjału energetycznego, koncepcje geotermalnego systemu grzewczego, propozycję zamiany spalania na OZE, studium wykonalności i analizę ekonomiczną planowanej ciepłowni geotermalnej w mieście Nowy Tomyśl. W pracy zostały przedstawione warunki geologiczne Województwa Wielkopolskiego oraz określone potencjalne zbiorniki geologiczne województwa, powiatu i Gminy Nowy Tomyśl, pozwalające na eksploatacje wód termalnych. Zbiorniki: Kredy Dolnej, Jury Dolnej, Triasu Dolnego i Permu Dolnego zostały przeanalizowane pod względem ich głębokości, temperatury, przewodności hydraulicznej i potencjalnej wydajności ujęć. Została przeprowadzona analiza stanu obecnego i przedstawiono ekologiczny możliwy wariant modernizacji ciepłowni i sieci cieplnej w Nowym Tomyślu. W modernizacji przewidziano zastosowanie sprężarkowych pomp ciepła dużej mocy (SPCDM), pozwalających na maksymalne wykorzystanie ciepła geotermalnego w wysokotemperaturowej miejskiej sieci ciepłowniczej. Przeprowadzono analizę ekonomiczną z określeniem średniego kosztu ciepła (LCoH) i przepływów pieniężnych dla różnych wariantów finansowania i zasilania projektu geotermalnego miasta.
EN
The article presents the energy potential, concept for the geothermal heating system, proposition for replacement of combustion with renewable energy, feasibility study and economic analysis of the planned geothermal heating plant in the city of Nowy Tomyśl. This study presents geological conditions of the Greater Poland province and choice of the potential aquifers for the province, municipality and city of Nowy Tomyśl, that allow exploitation of thermal water. Aquifers of Lower: Cretaceous, Jurassic, Triassic and Permian were analyzed for their depth, temperature, hydraulic conductivity and potential yield of the borehole. Analysis of the current state was performed, with proposition of the ecological modernization option of the heating plant and network in Nowy Tomyśl. Modernization was proposed with use of high-power compressor heat pumps, that allow maximal exploitation of the geothermal heat in high temperature municipal heating network. Economical analysis was performed with calculation of Cash flow and levelized cost of heat for different financing and power supply options.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.