Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 49

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
PL
W artykule przedstawiono metodykę wyznaczania współczynnika przejmowania ciepła na powierzchni walcowanego wsadu. Na podstawie obliczeń analitycznych wyznaczono wartości współczynnika konwekcji i współczynnika radiacji.
EN
The aim of this paper it to present a methodology of the heat transfer coefficient determination. The values of the convective and radiative coefficients were established on the basis of analytical calculation.
EN
The paper presents the experimental measurements dedicated to the research for the Rayleigh number (Ra) in the area of rectangular steel sections. This problem is associated with the analysis of the free convection which takes place in the heating of sections bundles during the heat treatment. The study was conducted for both steady and transient heat transfer. The values of the Ra number obtained for the tested sections allow to describe the phenomenon of convection on the basis of a very simple criterial dependence. It greatly simplifies the mathematical description of the heat transfer phenomenon in the concerned charges.
PL
W artykule przedstawiono wyniki badań eksperymentalnych, których celem było określonie liczby Rayleigha (Ra) dla profili prostokątnch, nagrzewanych w warunkach ustalonej i nieustalonej wymiany ciepła. Analizie poddano trzy rodzaje profili: 40x20 mm, 60x60 mm oraz 80x80 mm. Badania dla warunków ustalonych przeprowadzono w komorze grzewczej stanowiska do pomiarów efektywnej przewodności cieplnej wsadów porowatych. Natomiast badania w warunkach nieustalonych przeprowadzono w elektrycznym piecu komorowym. Charakter zmian liczby Ra w funkcji temperatury, dla obu sposobów nagrzewania jest podobny. W każdym z przypadków, maksymalną wartość parametr Ra uzyskuje w przedziale temperatury około 100200oC. Dla profili 80x80 mm parametr ten jest około sześciokrotnie większy w porównaniu z profilami 60x60 mm. W przypadku nieustalonego przepływu ciepła, bezwzględne wartości parametru Ra są o rząd wielkości większe od wartości uzyskanych dla warunków ustalonych. Odnotowane liczby Ra nie przekroczyły wartości 107. Maksymalna wartość tego parametru wyniosła około 1,2x106. Zatem przy nagrzewaniu analizowanych profili, występujacą w ich wnętrzu konwekcję, można traktować jako intensyfikację przewodzenia w wypełniającym je powietrzu. Wyniki przedstawionych badań posłużą do analizy wpływu występującej wewnątrz profili konwekcji, na proces nagrzewania wiązek tych elementów. Ostatecznym wynikiem prowadzonych w tym zakresie analiz, będzie opracowanie modelu do wyznaczania efektywnej przewodności cieplnej tego wsadu.
PL
W artykule dokonano identyfikacji mechanizmów wymiany ciepła, jakie występują w obszarze wiązek elementów długich podczas ich nagrzewania. Przedstawiona analiza stanowi punkt wyjściowy do analitycznego wyznaczania efektywnej przewodności cieplnej wiązek. Parametr ten jest podstawową własnością cieplną wiązek. Wiedza na temat tego współczynnika jest niezbędna do modelowania procesu nagrzewania wiązek. Problem ten jest związany z optymalizacją obróbki cieplnej wiązek stalowych elementów długich.
EN
In the article an identification of heat transfer mechanisms occurring in range of long elements bundles during heating was made. Presented analysis is a starting point for analytical determination of effective thermal conductivity of the bundles. This parameter is a basic thermal property of the bundles. Knowledge about this coefficient is necessary to modelling of bundles heating process. This problem is connected with heat treatment optimization of steel long elements bundles.
PL
W artykule dokonano charakterystyki wsadów porowatych spotykanych w praktyce przemysłowej obróbki cieplnej wyrobów metalowych. Identyfikacja cech geometrycznych tego typu elementów jest niezbędna przy wyznaczaniu ich przewodności cieplnej na drodze modelowej. Ponieważ są to elementy, w obszarze których podczas nagrzewania Występuje złożony przepływ ciepła, ich własności cieplne należy traktować jako wielkość o charakterze efektywnym. Wewnętrzna struktura geometryczna jest jednym z podstawowych czynników wpływających na wartość efektywnej przewodności cieplnej danego wsadu porowatego.
EN
The article characterizes porous charges that are found in the industrial practice of heat treatment of metal products. The identification of the geometrical characteristics of this type of elements is indispensable in determining their thermal conductivity by model means. As these are elements Within which a complex heat transfer occurs during heating, their thermal properties should be regarded as an effective quantity. The internal geometrical structure is one of the basic factors influencing the effective thermal conductivity of a given porous charge.
EN
Free convection is one of the heat transfer modes which occurs within the heat-treated bundles of steel rectangular section. A comprehensive study of this phenomenon is necessary for optimizing the heating process of this type of charge. The free convection intensity is represented by the Rayleigh number Ra. The value of this criterion depends on the following parameters: the mean section temperature, temperature difference within the section, kinematic coefficient of viscosity, volume expansion coefficient and the Prandtl number. The paper presents the analysis of the impact of these factors on free convection in steel rectangular sections. The starting point for this analysis were the results of experimental examinations. It was found that the highest intensity of this process occurs for the temperature of 100°C. This is mainly caused by changes in the temperature difference observed in the area of sections and changes in kinematic coefficient of viscosity of air. The increase in the value of the Rayleigh number criterion at the initial stage is attributable to changes in the parameter of temperature difference within the section. After exceeding 100°C, the main effect on convection is from changes in air viscosity. Thus, with further increase in temperature, the Rayleigh number starts to decline rapidly despite further rise in the difference in temperature.
6
100%
PL
W referacie przedstawiono badania związane z budową systemu monitorowania sieci wodociągowych, sygnalizujących pojawienie się awarii sieci i wspomagającego ich lokalizację. Podstawowym założeniem omawianego systemu było przyjęcie metody wykrywania awarii stosowanej dotychczas w diagnostyce technicznej maszyn i procesów przemysłowych, opartej o modele przybliżone obiektu diagnozowanego. Bazując na niewielkiej liczbie czujników przepływu zainstalowanych na sieci wodociągowej i odpowiednio wytrenowanej sztucznej sieci neuronowej pojawiające się awarie sieci są wykrywane i lokalizowane. Opisany został pierwszy etap prac (lokalizacja czujników pomiarowych, przygotowanie i trenowanie klasyfikatora neuronalnego) oraz uzyskane wyniki.
EN
In the paper an intelligent monitoring system of local water supply system was described. The author took advantage of methods of artificial intelligence and methods known from model-based process diagnostics to decrease the number of indispensable measuring points. Basing on few flow sensors installed on pipeline network and using neural network as a model of pipeline, appeared leakages are approximately localized. The first stage of system building (choosing of sensor localization, neural network preparing and training) and results obtained to-date were shown.
EN
Bundles of rectangular steel sections are examples of the porous charge. Due to the voids within the sections, this type of charge is characterized by porosity even exceeding 85%. This makes the thermal properties of these elements, expressed by the effective thermal conductivity kef, totally different from the thermal conductivity of steel. The value of the kef coefficient depends on many factors such as: the ratio of the thermal conductivity of steel to that of gas, the structure of the solid matrix and its porosity and the lack of the continuity of the steel phase. The paper describes experimental investigations concerning the measurements of the effective thermal conductivity of a steel sections bundles.
PL
Stalowe wyroby długie takie jak pręty, rury, profile czy różnego typu kształtowniki, podczas obróbki cieplnej nagrzewa się w postaci wiązek. Z punktu widzenia struktury wewnętrznej wsady tego typu, są niejednorodnym ośrodkiem porowatym. Cecha ta sprawia, że własności cieplne tych wsadów, wyrażane za pomocą efektywnej przewodności cieplnej kef są zupełnie odmienne od własności cieplnych samej stali. Wiedza na temat kształtowania się wartości współczynnika kef obrabianych cieplnie wiązek, jest istotna z punktu widzenia doboru optymalnych parametrów nagrzewania. W artykule przedstawiono wyniki pomiarów współczynnika kef wykonane dla próbek w postaci płaskich złóż stalowych profili prostokątnych. Badane złoża wykonano z czterech typów profili: 40x20 mm, 40x40 mm, 60x60 mm i 80x80 mm. Pomiary przeprowadzono według metody stanu ustalonego na stanowisku laboratoryjnym działającym na zasadzie jednopłytowego aparatu Poensgena. Wykazano iż badany parametr (oprócz próbek wykonanych z profili 40x20 mm) rośnie w funkcji temperatury. Ponadto jego wartość jest tym większa im większy jest rozmiar profilu tworzącego daną próbkę. Wartości bezwzględne efektywnej przewodności cieplnej badanych próbek, w zależności od temperatury i rodzaju profili, wynosiły od 3,2 do 6,8 W/(mxK). Wartości te stanowią od 0,8 do 0,18 przewodności cieplnej stali z których wykonano profile. Zaprezentowane badania, stanowią jeden z elementów prac prowadzonych przez autorów nad optymalizacją parametrów technologicznych procesów nagrzewania wiązek różnego typu elementów długich, związanych z ich obróbką cieplną.
EN
The reason for undertaking this study was to determine the possible involvement of natural convection in the global heat transfer, that occurs in the heated steel rods bed. This problem is related to the setting of the effective thermal conductivity of the bars bed. This value is one of the boundary conditions for heating modeling of steel rods bundles during heat treatment. The aim of this study was to determine for which geometry of the bed bars, there will be no free convection. To analyze the problem the Rayleigh criterion was used. It was assumed that for the value of the number Ra < 1700 convection in the bed bars does not occur. For analysis, the results of measurements of the temperature distribution in the unidirectionally heated beds of bars were used. It has been shown, that for obtained, during the test, differences of temperature between the surfaces of adjacent rods, convection can occur only when the diameter of the rod exceeds 18 mm.
EN
The paper discusses the structure and principle of operation of programs for integrated modelling of the processes of heat treatment of porous-structure steel charges, such as long product bundles or strip or wire coils. Consideration is given to the specificity of these models in respect to porous charges. This is associated with their untypical thermal properties, which are expressed using the concept of effective thermal conductivity.
PL
W artykule przedstawiono badania dotyczące detekcji małych wycieków pojawiających się w sieciach wodociągowych. W celu detekcji uszkodzeń zastosowano schemat diagnozowania w oparciu o residua wygenerowane za pomocą przybliżonych modeli obiektu. Część decyzyjną realizującą ocenę wartości chwilowych residuów opracowano na podstawie metody modelowania niepewności. Uzyskane wyniki badań potwierdzają poprawność zastosowanego rozwiązania.
EN
This paper considers the problem of small leakage detection in urban water supply networks. In order to detect leakage, the model-based fault diagnosis scheme was used. Nonlinear autoregressive exogenous models were applied to residual generation. A nonlinear part of the model was worked out with use of a multilayer perceptron neural network. Residual evaluation was realised basing on the model error modelling method. This method was modified to obtain a new scheme for adaptive threshold generation. In the case study reported in this paper the authors present the fault detection experiments with use of the industrial data set. The obtained results of small leakage detection in the considered water supply network confirm the effectiveness of the proposed approach. The paper is organized as follows. The first section deals with the introduction to the study. The second one includes a description of the proposed method. In the next section there are presented the results that were obtained by the authors. Finally, the paper ends with the conclusions.
PL
W artykule omówiono przykładową strukturę i zasadę działania modułu termicznego, jaki może być wykorzystany w programach do zintegrowanego modelowania procesów obróbki cieplnej wsadów stalowych o strukturze porowatej. Przedstawiono metodykę tworzenia schematu różnicowego dla dwu- wymiarowego elementu walcowego, jakim zastępuje się wsad w postaci wiązki prętów. Przedstawiono również metodykę określania efektywnej przewodności cieplnej wsadów porowatych bazującą na wykorzystaniu analogii cieplno-elektrycznej.
EN
Exemplary structure and work principle of the thermal module was discussed in the peper. This module can be used in programmes used for integrated modeling of heat treatment processes of the porous structure of the steel charges. The methodology of creating differencing scheme of two - dimensional cylindrical element, which is used to represent the charge in the form of a bundle of rods, was shown. The methodology of determining the effective thermal conductivity of porous charges based on the use of thermo-electric analogy also was presented.
EN
The paper presents the method of optimization of heuristic model of water supply system with Genetic Algorithm. This model is an essential part of intelligent diagnostic system of local water supply system. The main task of this system is water leakage detecting and localization. For inputs, this system uses information from pressure or flow sensors, mounted on the pipeline network, the output is a piece of information about leakage detection and localization. The main advantage of this system is a possibility of approximate leakage localization using only a limited number of installed sensors. The first problem which should be solved to apply this system in practice is to find the best localization of sensor which should be installed on water pipeline. The method of solving this problem was described in the paper.
PL
W artukule przedstawiono sposób optymalizacji heurystycznego modelu sieci wodociągowej, opartego o sztuczne sieci neuronowe, z zastosowaniem algorytmu genetycznego. Model ten stanowi zasadniczy element inteligentnego układu diagnozustyki sieci wodociągowej, mającego za zadanie wykrywanie przecieków sieci wodociągowej. Wejściami do modelu są dane z czujników ciśnienia lub przepływu zainstalowanych na sieci, zaś wyjściami informacja o lokalizacji potencjalnych przecieków. Podstawową zaletą tej koncepcji systemu diagnozowania sieci wodociągowej jest możliwość przybliżonej lokalizacji uszkodzeń sieci w oparciu o ograniczoną liczbę czujników na niej zainstalowanych. Istotnym problemem który należy rozwiązać w pierwszym etapie budowy systemu, jest wybór lokalizacji ograniczonej liczby czujników, zapewniających jednak identyfikowanie jak największej liczby potencjalnych awarii. Artykuł przedstawia sposób rozwiązania tego problemu poprzez optymalizację rozmieszczenia czujników z zastosowaniem algorytmu genetycznego.
PL
Pręty stalowe wytwarzane są w procesie walcowania, przez co charakteryzują się umocnieniem i niskimi własnościami plastycznymi. Dla wielu zastosowań własności takie są nieodpowiednie, co wymusza realizację obróbki cieplnej prętów. W artykule zilustrowano ten proces dla nagrzewania prętów w formie cylindrycznych wiązek. Przeanalizowano problem transportu ciepła w obszarze wiązki prętów, z uwzględnieniem problemu powstawania na ich powierzchni warstwy zgorzeliny. Dokonano również analizy wyników badań wstępnych dotyczących tego problemu.
EN
Steel bars are manufactured in the rolling process, whereby they are characterized by strain hardening and poor plastic properties. In many application instances such properties and inadequate, which necessitates heat treatment. The article illustrates the way in which this process is carried out. Moreover, it examines the heat transfer process in a bundle of steel bars, while allowing for the problem of formation of a scale layer on the bar surface. An analysis of the results of preliminary research into this problem has also been made.
PL
W artykule przedstawiono problem przewodzenia kontaktowego występującego podczas procesów obróbki cieplnej stalowego wsadu porowatego. Podstawą do przeprowadzonej analizy były wyniki badań eksperymentalnych efektywnej przewodności cieplnej kef płaskich złóż prętów o różnym sposobie ułożenia (przestawionym, szeregowym i krzyżowym). Badaniom poddano 12 próbek zbudowanych z prętów o średnicach 10, 20, 30 i 40 mm – po trzy próbki dla każdej średnicy. Następnie na podstawie analizy oporów termicznych dokonano obliczeń współczynnika przewodzenia kontaktowego hkt tych próbek. Parametr ten dla analizowanych próbek zależnie od ich ułożenia, średnicy prętów oraz temperatury wynosi od 50 do 175 W/(m2×K).
EN
The article presents problem of thermal contact conduction during heat treatment processes of steel porous charge. Experimental research results of effective thermal conductivity kef of flat bar beds with various arrangements (shifted, serial and crossed) were used in this analysis. Tests were realised for 12 samples with a different bar diameter – 10, 20, 30 and 40 mm – three samples of each type. Finally, based on analysis of samples thermal resistance, thermal contact conductance was calculated hkt. The thermal contact conductance for analysed samples depends on alignment, diameter and temperature and its value is between 50 and 175 W/(m2×K).
PL
Przedmiotem zainteresowania i rozważań w niniejszym referacie jest wykorzystanie inżynierii wiedzy w zakresie metod wspomagania przygotowywania i weryfikacji procedur pomiarowych. Przedstawiono koncepcję sposobu pozyskiwania i zapisu wiedzy niezbędnej do poprawnego przygotowania tych procedur oraz jej praktycznego wykorzystania do budowy narzędzi komputerowych wspomagających ten proces.
EN
The subject of interest and discussion of the paper is the use of knowledge engineering for methods supporting the preparation and verification of the measurement procedures. The idea of the method for obtaining and recording the necessary knowledge for proper preparation of these procedures and its practical use for building computer tools supporting this process have been presented in the paper.
PL
W artykule przedstawiono wyniki obliczeń współczynników wnikania ciepła (całkowitego, konwekcyjnego i radiacyjnego) uzyskane dla wsadu w kształcie walca nagrzewanego w elektrycznym piecu komorowym. Obliczenia wykonano na drodze numerycznej, z wykorzystaniem metody różnic skończonych. Do wykonania obliczeń wykorzystano dane z pomiarów eksperymentalnych. Otrzymane wyniki obliczeń dają zarówno ilościowy, jak i jakościowy obraz analizowanego zagadnienia. W drugim przypadku, wskazują na udział poszczególnych sposobów wymiany ciepła (konwekcja swobodna, promieniowanie cieplne) w dostarczaniu ciepła do powierzchni nagrzewanego wsadu.
EN
The article presents the results of a calculation of heat transfer coefficients (total, convection and radiation) obtained for the charge in the form of a cylinder to be heated in the electric furnace chamber. The calculations were performed numerically using the finite difference method. To the calculation were used the data of measurements performed in the laboratory. The obtained results gives both quantitative and qualitative information about analysed issue. In the second case, it shows the participation of the various mechanisms of heat transfer (free convection, thermal radiation) through which the heat is supplied to the treated charge.
PL
Artykuł przedstawia realizację koncepcji wielomodelu eksploatacyjnego w odniesieniu do systemów inżynierii miejskiej. Autorzy podjęli próbę matematycznego zapisu poszczególnych składników wielomodelu z wykorzystaniem elementów teorii grafów. Opracowane macierze zostały poddane praktycznej interpretacji w warunkach budowy i funkcjonowania przykładowego systemu wodociągowego.
EN
The article presents the implementation of the exploitation multi-model concept for the municipal engineering systems. The authors made an attempt to mathematical description of the individual components of multi-model, using elements of the graph theory. Developing matrices have been subjected to practical interpretation in terms of construction and functioning of sample water supply system.
18
Content available remote An optimization of heuristic model of water supply network
63%
EN
In the paper an intelligent monitoring system of local water supply system is described. The main task of this system concerns water leakages detecting. For inputs, this system uses information from few pressure or flow sensors, mounted on the pipeline network, the output is a piece of information about leakage detection and localization. A heuristic model of water supply network makes the main part of intelligent diagnostic system. The model was built with the use of artificial neural networks. This paper presents the structure and optimization of a heuristic model. The authors took advantage of methods of artificial intelligence and methods known from model-based process diagnostics to increase the accuracy with which system detects of water leakages.
EN
Steel bars are manufactured in the rolling process, whereby they are characterized by strain hardening and poor plastic properties. In many application cases such properties are improper, therefore, additional heat treatment is required. Crucial influence on the products quality after heat treatment has an appropriate selection of process parameters. In many modern technologies of heat treatment the charge of porous structure is subjected to the heating process. Proper control of heat treatment parameters of bundles of rods requires knowledge on their thermal properties. However, it also requires accurate identification of complex heat transfer processes occurring in the porous material. Such analysis, with respect to bundles of bars, provide a response of qualitative nature of the heat exchange area of these charges. The article describes the emissivity measurements of samples of the steel charge using a thermal imaging camera.
PL
W artykule przedstawiono wyniki badań efektywnego współczynnika przewodzenia ciepła uzwojenia drutu stalowego w zależności od porowatości zwoju (liczba dystansu), średnicy i emisyjności drutu oraz temperatury podgrzewania zwoju. Prezentowane wyniki uzyskano na podstawie rozwiązania numerycznego modelu matematycznego przewodzenia i radiacyjnej wymiany ciepła w uzwojeniu drutu. W modelu pominięto konwekcyjną wymianę ciepła, przyjmując próżnię w otoczeniu uzwojenia.
EN
The paper contains calculation results of the effective thermal conductivity of a coiled steel wire as a function of coli porosity (distance number of coli), diameter, emissivity and heating temperature of coiled wire. The presented data were obtained from a numerical solution of mathematical model of conduction and radiation heat transfer inside coiled wire. Convection was neglected by the assumption that there was vacuum inside heating chamber.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.