Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Stationary gas slug attached to the gas sparger in the downcomer of an air-lift fermenter can cause serious operational problems. The results of experimental investigation on the influence of liquid. and gas flow rates on the behavior of an attached bubble formed in a vertical pipe have been presented. The size distribution of the bubbles shed from the gas slug base in the mixing zone has also been measured and correlated with the mean energy dissipation rate in the zone.
PL
Stacjonarne korki gazowe tworzące się pod dystrybutorem gazu w pionowych rurach (downcomer) bioreaktorów typu air-lift są niepożądanym zjawiskiem utrudniającym pracę tych urządzeń. Przedstawiono wyniki pomiarów wpływu prędkości cieczy oraz gazu (zasilania) na zachowanie się korków gazowych w pionowej rurze z centralnie umieszczonym dystrybutorem gazu. Zmierzono także rozkład średnic małych pęcherzy odrywanych w strefie intensywnego mieszania, które skorelowano ze średnią szybkością dyssypacji energii w tej strefie.
PL
W pracy przedstawiono wyniki symulacji CFO wirującego walcowego dystrybutora gazu w pionowym kanale, w warunkach przepływu jednofazowego oraz w dwufazowego z uwzględnieniem kawerny gazowej utworzonej pod dystrybutorem. Przedstawiono wyniki pomiarów pola prędkości uzyskane techniką anemometrii obrazowej (PIV), które porównano z wynikami obliczeń.
EN
The results of CFD simulation of a rotating cylindrical gas sparger in a downflowing liquid are presented. The simulations cover one-phase flow (73% aqueous glycerol) and two-phase flow (air-water) with special care taken to modelling the gas cavity that forms under such conditions. The velocity field measured with the aid of Particle Image Velocimetry (PIV) is compared with the simulation results for the case of one-phase flow.
EN
Electroflotation is used in the water treatment industry for the recovery of suspended particles. In this study the bubble formation and release of hydrogen bubbles generated electrolytically from a platinum cathode was investigated. Previously, it was found that both the growth rate and detachment diameter increased with increasing wire diameter. Conversely, current density had little effect on the released bubble size. It was also found that the detached bubbles rapidly increased in volume as they rose through the liquid as a result of decreasing hydrostatic pressure and high levels of dissolved hydrogen gas in the surrounding liquid. The experimental system was computationally modelled using a Lagrangian-Eulerian Discrete Particle approach. It was revealed that desorption of gaseous solutes from the electrolyte solution, other than hydrogen, may have a significant impact on the diameter variation of the formed bubbles. The simulation confirmed that liquid circulation, either forced or induced by the rising bubble plume, influences both the hydrogen supersaturation (concentration) in the neighbourhood of the electrode and the size of the resulting bubbles.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.