Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
|
|
tom 64
|
nr 2
193-198
EN
Background: Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Material and Methods: Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers), Iran (5), China (4) and India (5). Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m³ of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. Results: We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings). In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. Conclusions: The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program. Med Pr 2013;64(2):193–198
PL
Wstęp: W wodach geotermalnych znajduje się m.in. rozpuszczalny gaz - α-promieniotwórczy radon, który stanowi zagrożenie dla zdrowia człowieka, szczególnie po przedostaniu się do jego dróg oddechowych. Ośrodki SPA, które wykorzystują wody geotermalne, mogą stanowić źródło zwiększonej dawki promieniowania dla osób w nich przebywających. Celem pracy było oszacowanie dawek otrzymanych przez pracowników i kuracjuszy zażywających relaksu na podstawie informacji o stężeniu radonu dostępnych w publikacjach naukowych. Materiał i metody: Analizowano wartości stężeń radonu w 17 geotermalnych placówkach: 3 w Grecji, 5 w Iranie, 4 w Chinach i 5 w Indiach. Z wykorzystaniem zależności mówiącej, że 1-godzinna ekspozycja na stężenie radonu 1 Bq/m³ przy współczynniku równowagi F = 0,4 odpowiada dawce efektywnej 3,2 nSv, oszacowano dawki otrzymane przez ludzi przebywających w SPA. Wyniki: Stwierdzono, że poziom stężenia radonu w SPA jest od kilku do kilkunastu razy wyższy od stężenia w zamkniętych pomieszczeniach, np. w budynkach mieszkalnych, w których nie wykorzystuje się wód geotermalnych. W 82% analizowanych SPA istniało niebezpieczeństwo otrzymania przez pracownika dawki wyższej niż 1 mSv/rok, co zgodnie z polskim prawodawstwem kwalifikuje taką osobę do kategorii B narażenia radiacyjnego (m.in. do objęcia kontrolą dozymetryczną). Dawki pochłonięte przez kuracjuszy są dużo niższe ze względu na ich krótki czas przebywania w narażeniu na radon emitowany przez wody geotermalne. Wnioski: Analiza stężeń radonu w placówkach SPA pokazuje, że temat ochrony radiologicznej osób pracujących przy wodach geotermalnych jest istotny. Należałoby objąć takich pracowników geotermalnych kontrolą dozymetryczną. Med. Pr. 2013;64(2):193–198
EN
Introduction: The paper reports the results of the determinations of UMTS EMF distributions in the driver's cab of motor vehicle simulators. The results will serve as the basis for future research on the influence of EMF emitted by mobile phones on driver physiology. Materials and Methods: Two motor vehicle driving simulators were monitored, while an EMF source was placed at the driver's head or on the dashboard of the motor vehicle driving simulator. For every applied configuration, the maximal electric field strength was measured, as were the values at 16 points corresponding to chosen locations on a driver's or passenger's body. Results: When the power was set for the maximum (49 mW), a value of 27 V/m was measured in the vicinity of the driver's head when the phone was close to the head. With the same power, when the phone was placed on the dashboard, the measured maximum was 15.2 V/m in the vicinity of the driver's foot. Similar results were obtained for the passenger. Significant perturbations in EMF distribution and an increase in electric field strength values in the motor vehicle driving simulator were also observed in comparison to free space measurements, and the electric field strength was up to 3 times higher inside the simulator. Conclusions: This study can act as the basis of future studies concerning the influence of the EMF emitted by mobile phones on the physiology of the driver. Additionally, the authors postulate that it is advisable to keep mobile phones at a distance from the head, i.e. use, whenever possible, hands-free kits to reduce EMF exposure, both for drivers and passengers.
EN
Objective: Mobile phones generate microwave radiation which is absorbed by exposed tissue and converted into heat. It may cause detrimental health effects. The aim of the experiment was to check if exposure to EMF emitted by mobile phone influenced the tympanic temperature. Material and Methods: Human volunteer study was performed on ten healthy young men, aged 22.1±4.7 years, examined three times: 1. on a day with 2×60 min of no exposure (sham day), 2. on a day with continuous, 60 min exposure and 60 min of no exposure, 3. on a day with intermittent exposure (4×15 min “on” and 4×15 min “off”). Exposure was generated by mobile phone (frequency 900 MHz, SAR 1.23 W/kg). The study was double-blind, performed under controlled conditions (at 24°C and 70% humidity). The tympanic temperature (Tty) was monitored every 10 sec by a thermistor probe placed close to the aural canal membrane in the ear opposite the one in contact with mobile phone (contralateral position). Multivariate repeated-measures analysis of variance was used to calculate the results. Results: The mean Tty in the whole group during continuous exposure was significantly higher than during sham exposure (p = 0.0001). During intermittent exposure the temperature was lower than during sham day (difference was up to 0.11°C). Within an hour after continuous exposure, Tty was higher by 0.03°C and after intermittent exposure Tty was lower by 0.18°C in comparison with sham day. Two hours after exposure Tty was significantly lower (p = 0.0001) than after sham exposure (0.06°C and 0.26°C respectively). The trends in Tty during experiment differed significantly in relation to exposure conditions (p < 0.05). Conclusions: The results of this analysis indicate that the physiological response to EMF exposure from mobile phone was mostly related to type of exposure (continuous or intermittent).
EN
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent HP(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and γ were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and γ beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer of interlaboratory comparisons. Results: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent HP(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent HP(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed. Med Pr 2013;64(5):631–637
PL
Wstęp: Celem pracy było potwierdzenie, na podstawie wyników porównań międzylaboratoryjnych dla dozymetrów pierścionkowych, że stosowana metoda badawcza jest odpowiednia do pomiaru indywidualnego równoważnika dawki HP(0,07). Ponadto w pracy przedstawiono procedury kalibracyjne stosowane podczas walidacji metody badawczej przed wdrożeniem do rutynowych pomiarów związanych z oceną narażenia pracowników na działanie promieniowania X i γ. Materiał i metody: Przedmiotem porównań międzylaboratoryjnych były dozymetry pierścionkowe wykonane z elastycznego tworzywa o standardowej średnicy 20 mm i z umieszczonymi wewnątrz dwoma detektorami termoluminescencyjnymi (TL) typu MTS-N - po naeksponowaniu u organizatora porównań odczytywano je za pomocą nowego, manualnego czytnika detektorów TL (prod. FIMEL, Francja). Wszystkie ekspozycje dozymetrów, przeprowadzone dla celów walidacyjnych ww. czytnika, wykonano we wzorcowych wiązkach promieniowania X i γ z zastosowaniem fantomu prętowego ISO. Metodyka wykonanych ekspozycji była odpowiednia do potrzeb pracowni oraz zgodna z metodami stosowanymi przez Europejskę Grupę ds. Dozymetrii Promieniowania (European Radiation Dosimetry Group - EURADOS) - organizatora porównań międzylaboratoryjnych o europejskim zasięgu w zakresie dozymetrii indywidualnej. Wyniki: Wykonane charakterystyki - energetyczna, dawkowa i kątowa dozymetru pierścionkowego - umożliwiły opracowanie wzoru dotyczącego oszacowania indywidualnego równoważnika dawki HP(0,07) oraz poddania go testowi weryfikacyjnemu. Stwierdzono zadowalający wynik testu oceny wielkości HP(0,07) i tym samym potwierdzono gotowość wdrożenia czytnika termoluminescencyjnego do stosowanej metody badawczej oraz uczestniczenia w porównaniach międzylaboratoryjnych. Wnioski: Laboratorium - zgodnie z wymaganiami Polskiego Centrum Akredytacji - uczestniczyło w porównaniach międzylaboratoryjnych (organizowanych przez grupę EURADOS) w zakresie pomiaru dawki równoważnej na ręce promieniowania jonizującego X i γ. Wynik porównania był pozytywny, a jego przedmiotem były dozymetry pierścionkowe. Potwierdzono tym samym prawidłowość realizowanej procedury badawczej. Med. Pr. 2013;64(5):631–637
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.