Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
|
|
nr 1(23)
153-179
EN
Moral life is a dynamic process of constant recognizing of God's will and the man’s re-sponse to God in the concrete conditions in which man finds himself. This process is marked by a specific tension between the objective and unchangeable law of God, and the changing situations and circumstances that give human choices unique character. Bearing in mind that dynamism, the Church’s pastoral reflection developed a category of gradual law that applied to marriage and family life in the exhortation of John Paul II, Familiaris consortio and later in Francis’ exhortation Amoris laetitia. The purpose of the article is to analyze both the category of the law of gradualness, its theological interpretations, and the manner in which it can be applied in the pastoral practice offered by the papal documents.
PL
Życie moralne jest dynamicznym procesem nieustannego rozpoznawania woli Boga i odpowiedzi człowieka na Boże wezwanie skierowane do niego w konkretnych uwarunkowaniach, w których się znajduje. Ten proces jest naznaczony swoistym napięciem między obiektywnym i niezmiennym prawem Bożym, a zmieniającymi się sytuacjami i okolicznościami, które nadają ludzkim wyborom charakter niepowtarzalny. Mając na uwadze ów dynamizm refleksja duszpasterska Kościoła wypracowała kategorię prawa stopniowości, która znalazła zastosowanie w odniesieniu do małżeństwa i życia rodzinnego w adhortacji Jana Pawła II Familiaris consortio, a później w adhortacji Franciszka Amoris laetitia. Celem artykułu jest analiza zarówno samej kategorii prawa stopniowości, jego interpretacji teologicznych, jak też sposobu stosowania go w duszpasterstwie, które proponują dokumenty papieskie.
|
|
tom 64
|
nr 5
671-680
EN
Background: The activities of rescue and uniformed services require the use of wireless communication devices, such as portable radiophones. Assessment of workers' exposure to electromagnetic fields emitted by radiophones is important in view of occupational safety and health (OSH), legislation requirements and reports on possible adverse health effects in users of devices emitting radiofrequency electromagnetic field. Materials and Methods: In this study 50 portable radiophones of conventional and trunked communication systems were investigated. The assessment of electromagnetic hazards to users involved unperturbed electromagnetic field measurements near radiophones' antennas. Results: The electric field strength corresponding to the occupational exposure level (fields of so-called safety zones established by OSH legislation in Poland) was measured at a distance of 45-65 cm from the portable radiophones antennas of conventional system and 75-95 cm from antennas of trunked system radiophones, depending on their type and mode of work. The assessment was based on the averaged results of series of measurements. The electric field strength exceeding action levels defined by Directive 2013/35/EU was found up to 15 cm from radiophone antennas of conventional system and up to 10 cm from the antennas of trunked system radiophones. Conclusions: Taking into account the range of safety zones and the use of portable radiophones near the body, their users should be classified into the group of workers occupationally exposed to electromagnetic fields. Electromagnetic field measurement results and typical conditions of using portable radiophones justify theneed for additional assessment of electromagnetic hazards - the analysis of compliance with relevant exposure limit values provided by Directive 2013/35/EU. Med Pr 2013;64(5):671–680
PL
Wprowadzenie: Funkcjonowanie służb ratunkowych i mundurowych wymaga wykorzystania urządzeń łączności bezprzewodowej, takich jak radiotelefony. Ocena narażenia pracowników na wytwarzane przez nie pola elektromagnetyczne jest istotna ze względu na wymagania prawa pracy, a także doniesienia literaturowe dotyczące możliwych zagrożeń zdrowia użytkowników urządzeń, które emitują pole elektromagnetyczne o częstotliwościach radiowych. Materiały i metody: Badaniami objęto 50 radiotelefonów przenośnych konwencjonalnego i trankingowego systemu łączności. Zagrożenia elektromagnetyczne dla użytkowników oceniono z wykorzystaniem wyników pomiarów pierwotnego pola elektromagnetycznego, przeprowadzonych w otoczeniu anten radiotelefonów. Wyniki: Pole elektryczne o natężeniu odpowiadającym ekspozycji zawodowej (tj. według wymagań polskiego prawa pracy - ekspozycji na pola tzw. stref ochronnych) zmierzono w odległości dochodzącej do: 45-65 cm od anten radiotelefonów pracujących w systemie konwencjonalnym i 75-95 cm od radiotelefonów systemu trankingowego, zależnie od ich typu i trybu pracy - ocena na podstawie średnich wyników wykonanych serii badań. Pole elektryczne o natężeniach przekraczających tzw. interwencyjny poziomom narażenia, określony w Dyrektywie 2013/35/UE, stwierdzono w odległości do ok. 15 cm od anteny radiotelefonów systemu konwencjonalnego i do ok. 10 cm od radiotelefonów systemu trankingowego. Wnioski: Z uwagi na zasięg stref ochronnych i użytkowanie radiotelefonów przenośnych bezpośrednio przy ciele ich użytkownicy powinni być zaliczani do grupy pracowników, którzy podlegają ekspozycji zawodowej na pola elektromagnetyczne. Wyniki wykonanych pomiarów pola elektromagnetycznego oraz typowe warunki użytkowania radiotelefonów uzasadniają konieczność przeprowadzenia dodatkowej oceny zagrożeń elektromagnetycznych - zbadania zgodności z tzw. granicznym poziomem oddziaływania określonym Dyrektywą 2013/35/EU. Med. Pr. 2013;64(5):671–680
|
|
tom 64
|
nr 4
487-501
EN
Background: Use of electro surgery units (ESU) in surgeries is linked with electromagnetic field emission, which is assessed according to the requirements of occupational health and safety legislation. Material and Methods: Surgeons' exposure characteristics was monitored during 11 surgeries (proctectomy, patency of artery, hepatectomy, cystectomy, tonsilectomy, laparoscopy) by real time of monopolar ESU activity recorder. Investigations of root-mean-square value of electric and magnetic field strength was also performed at various modes of ESU operations during cutting (output power, 55-150 W; frequency, 330-445 kHz) and coagulating (40-240 W, 335-770 kHz). Statistical parameters of distribution of ESU operation over any 6-min periods (according to international requirements regarding protection against adverse thermal effects of electromagnetic field) were assessed. Results: Electric field strength, measured 10 cm from the cable supplying an active electrode was 147-675 V/m during cutting and 297-558 V/m during coagulating; magnetic field strength was less than 0.2 A/m in both modes. Monitoring of ESUs showed the following ranges of their operation during surgeries 5-66% of time over starting 3 min of surgery, 3-40% over starting 6 min, and the distribution of their use over any 6-min periods 0-12% (median) / 7-43% (maximum value). Conclusions: The real operation time of ESUs wykoduring surgeries was significantly shorter than that declared by workers. The distance of at least 15 cm between cables, connecting electrodes with generator and workers meets the requirements of the Polish legislation on permissible exposure limits. The assessment of localized exposure of the hand needs a detailed analysis of the SAR ratio distribution and further studies are required. Med Pr 2013;64(4):487–501
PL
Wstęp: Wykorzystanie diatermii chirurgicznej w zabiegach operacyjnych związane jest z emisją pola elektromagnetycznego, które podlega ocenie ze względu na wymagania przepisów bezpieczeństwa i higieny pracy. Materiał i metody: Monitoring charakterystyki narażenia chirurgów wykonano w czasie 11 operacji (resekcja: odbytnicza, wątroby, guza pęcherza moczowego, migdałków, udrożnienie tętnicy i zabiegi laparoskopowe), wykorzystując rejestrator czasu rzeczywistej aktywności monopolarnych diatermii chirurgicznych w czasie zabiegów. Wykonano również badania wartości skutecznej natężenia pola elektrycznego i magnetycznego przy różnych trybach pracy urządzeń (moc: 55-150 W, częstotliwość: 330-445 kHz przy cięciu; 40-240 W, 335-770 kHz przy koagulacji). Dla każdej operacji oceniono parametry statystyczne rozkładu czasu użycia diatermii w okresie dowolnych 6 min (zgodnie z międzynarodowymi zaleceniami dotyczącymi ochrony przed niepożądanymi skutkami termicznymi oddziaływania pola elektromagnetycznego). Wyniki: Natężenie pola elektrycznego, zmierzone 10 cm od kabla zasilającego elektrodę czynną, wynosiło 147-675 V/m przy cięciu i 297-558 V/m przy koagulacji, a magnetycznego nie przekraczało 0,2 A/m przy obu trybach. Monitoring pracy diatermii w czasie operacji wykazał ich wykorzystanie w zakresie 5-66% czasu w ciągu początkowych 3 min zabiegu, 3-40% - w ciągu początkowych 6 min. Rozkład współczynnika ich wykorzystania podczas dowolnych 6-minutowych okresów charakteryzuje zakres: 0-12% (mediana) / 7-43% (wartość maksymalna). Wnioski: Rzeczywisty czas użycia diatermii chirurgicznej w czasie zabiegów jest zdecydowanie krótszy niż deklarowany przez pracowników. Przy co najmniej 15-centymetrowej odległości pracowników od kabli łączących elektrody z generatorem wymagania przepisów krajowych odnośnie do dopuszczalnego poziomu ekspozycji są spełnione. Ocena lokalnych narażeń w dłoni wymaga szczegółowej analizy rozkładu współczynnika SAR i dalszych badań. Med. Pr. 2013;64(4):487–501
|
|
tom 64
|
nr 6
817-827
EN
Background: The assessment of electromagnetic field distribution near radiophones and their use warranted an analysis of thermal exposure hazards and related health effects, based on i.e. numerical calculations of specific energy absorption rate (SAR). Materials and Methods: The investigation concerned radiophones of conventional and trunked communication systems. Electromagnetic hazards assessment involved numerical simulations of SAR inside users' models (male and female) for 5 radiophones locations - near the ear, arm, chest, hip and face. Results: Maximum SAR (10 g) values depend on radiophone type, output power and locations. Near the chest, hip and face they are 6-, 2- and 2-fold higher than for location near the ear. SAR (10 g) may exceed Directive 2013/35/EU limits at maximum (4 W) output power of conventional radiophones, and the distance between antenna and worker's body shorter than 5 cm. SAR (10 g) values near trunked radiophones do not exceed 35% of the Directive limits. The Polish safety and health regulations in particular cases of radiophones use and local exposure may not guarantee the compliance with Directive 2013/35/EU requirements, i.e. SAR (10 g) may locally exceed exposure limit values (ELVs) during exposure to electromagnetic fields of hazardous, and even intermediate zones. Conclusions: It was demonstrated that exposure of trunked radiophones users does not exceed the limits laid down in the Polish safety and health regulations and Directive 2013/35/EU, however, in particular scenarios of the conventional radiophones use overexposure can be observed. The results showed that in exposure to electromagnetic field emitted by sources located near workers' body there is a need for more detailed analysis of the compliance of Polish safety and health regulations with Directive 2013/35/EU requirements. Med Pr 2013;64(6):817–827
PL
Wprowadzenie: Ocena rozkładu pola elektromagnetycznego w otoczeniu radiotelefonów i warunki ich eksploatacji uzasadniają analizę zagrożeń wynikających ze skutków termicznych ekspozycji. Oceniane są one na podstawie obliczeń numerycznych współczynnika szybkości pochłaniania właściwego energii (SAR). Materiały i metody: Badaniami objęto radiotelefony przenośne konwencjonalnego i trankingowego systemu łączności. Ocenę zagrożeń elektromagnetycznych wykonano w oparciu o symulacje numeryczne SAR w modelach ciała użytkowników radiotelefonów (mężczyzny i kobiety) przy 5 lokalizacjach radiotelefonu - przy uchu, ramieniu, klatce piersiowej, biodrze i twarzy. Wyniki: Wartości maksymalne SAR (10 g) zależą od typu radiotelefonu, jego mocy wyjściowej i lokalizacji - przy klatce piersiowej, biodrze i twarzy wartości są odpowiednio: 6-, 2- i 2-krotnie większe niż dla lokalizacji przy uchu. Przy maksymalnej mocy wyjściowej radiotelefonów systemu konwencjonalnego (4 W) mogą one przekroczyć limity Dyrektywy 2013/35/UE przy odległości anteny mniejszej niż 5 cm od ciała użytkownika. Przy radiotelefonach systemu trankingowego wartości SAR (10 g) nie przekraczają 35% wartości dopuszczalnej. Spełnienie wymagań polskich przepisów w niektórych warunkach korzystania z radiotelefonów i ekspozycji miejscowej może nie zapewniać zgodności z wymaganiami Dyrektywy 2013/35/UE, tzn. SAR (10 g) może lokalnie przekraczać GPO (graniczny poziom oddziaływania) podczas narażenia na pola strefy zagrożenia, a nawet pośredniej. Wnioski: Wykazano, że użytkownicy radiotelefonów systemu trankingowego nie podlegają ekspozycji przekraczającej wymagania prawa pracy w Polsce i Dyrektywy 2013/35/UE, natomiast w niektórych scenariuszach wykorzystania radiotelefonów systemu konwencjonalnego narażenie je przekracza. Wykazano również konieczność bardziej szczegółowej analizy zgodności polskich przepisów z wymaganiami Dyrektywy 2013/35/UE, dotyczącej narażenia miejscowego przy źródłach pola elektromagnetycznego zlokalizowanych bezpośrednio przy ciele pracownika. Med. Pr. 2013;64(6):817–827