In present work, an approach to porous PEO coating sublayers determination on the basis of Glow-Discharge Optical Emission Spectroscopy (GDOES) measurements, is presented. CP Titanium Grade 2 was used for the study. By interpreting the depth profiles obtained by GDOES, the Authors could reveal boundaries of zones with specific features in the obtained coating. This way the porous PEO coating can be divided into different sublayers. The use of the first and second derivatives of hydrogen, phosphorus and titanium signals in the GD profiles allowed to determine thesesub-layers, with results shown in that article