Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 27

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
2
100%
|
|
tom nr 4(48)
113-118
EN
This paper presents the technical state identification of rolling bearings by the quasi - dynamic method, where a physical pendulum was used as an investigative tool. For the presented method, the attributes of the diagnostic signal were distinguished. The attributes enable evaluation of the technical state of a rolling bearing over repairing. The coefficient of resistance to motion of a bearing was used as a generalized diagnostic parameter and power and moment of friction were used as a wear measure of a rolling bearing.
PL
W pracy przedstawiono sposób identyfikacji stanu technicznego łożysk tocznych, metodą quasi-dynamiczną w której jako narzędzie badawcze zastosowano wahadła fizyczne. Dla prezentowanej metody wyróżniono cechy sygnału diagnostycznego umożliwiającego ocenę stanu technicznego łożyska tocznego na etapie naprawy. W artykule wskazano na współczynnik oporu ruchu łożyska jako uogólniony parametr diagnostyczny oraz na moc i moment tarcia jako miarę intensywności zużycia łożyska tocznego.
|
|
tom Nr 3
125--136
PL
W artykule przedstawiona została metoda identyfikacji procesu niszczenia przekroju próbki badawczej oraz próba opisu tego zjawiska za pomocą modelu matematycznego z wykorzystaniem równań Lagrang’a. Proces destrukcji przekroju próbek badawczych realizowany był przez siłę bezwładności obiektu konstrukcyjnego. W opracowaniu zamieszczone zostały wyniki symulacji dla opracowanego modelu matematycznego, a także wyniki pomiarów zgodności modelu z rzeczywistością w oparciu o badania laboratoryjne i eksploatacyjne, na przykładzie elementów przyłączy kontrolno-pomiarowych instalacji rurowych. W oparciu o opracowany model, przeprowadzono analizę wpływu podstawowych parametrów modalnych struktury w postaci współczynnika tłumienia, sprężystości oraz częstotliwości drgań własnych na wielkość energii mechanicznej, generowanej podczas procesu eksploatacji przyłącza manometrycznego.
EN
The article presents the identification method of a specimen cross-section destruction and the attempt to describe this phenomenon with a mathematical model using Lagrange’s equations. The destruction process of specimens was carried out by inertia force of a structural object. The study includes not only the results of a simulation for a developed mathematical model but also those referring to the measurement of compliance between a model and reality based on laboratory and operational tests, with components of control and measurement couplings of piping installations used as examples. Based on a worked out model, the authors carried out the analysis of the impact of basic modal parametres of the structure in the form of a dampening coefficient, elasticity and natural modes on the magnitude of mechanical energy pgenerated during the operation of manometric coupling.
|
|
tom nr 6
1285--1291
PL
W artykule przedstawiono koncepcję nieinwazyjnej metody identyfikacji stanu technicznego obręczy kół, w celu wyznaczenia ich aktualnego stanu technicznego. Procedura badawcza obejmuje analizę widma drgań w dziedzinie częstotliwości uzyskanej z badanej obręczy koła, poddanej wymuszonym drganiom mechanicznym o określonych parametrach. W wyniku analizy i obliczeń wyznaczona została częstotliwość drgań własnych oraz dekrement tłumienia badanej obręczy koła, co pozwoliło ocenić sztywność i tłumienie obiektu. Na podstawie tych parametrów określony został aktualny stan połączeń (spawanych, zgrzewanych) oraz zidentyfikowano pęknięcia badanej obręczy koła lub utratę ciągłości struktury. Metoda ta ma mieć zastosowanie do badań zarówno obręczy nowych jak i używanych, pojazdów samochodowych, specjalnych i wolnobieżnych. Metoda badawcza jest nieinwazyjny oraz nie będzie powodował uszkodzeń obiektu badań. Czas pomiaru będzie uzależniony od wielkości obręczy koła, ale nie powinien przekraczać kilkunastu sekund.
EN
The aim of this paper was to develop a non-invasive method for identification of the technical state of rims for special slow motion vehicles and cars, and also to build and test the prototype device in the industrial conditions using the above-mentioned method. The research will include the analysis of vibrations concerning the resonant frequencies. As the results of the analysis and calculations the oscillation frequency and damping decrement of the rim will be determined. It will allow to evaluate the rigidity and damping of the product. It will be possible to detect a defect of the tested product based on these parameters.
|
|
tom nr 2(42)
57-62
PL
W pracy zaproponowano metodę identyfikacji stanu technicznego układu hydraulicznego na podstawie analizy charakterystyk dynamicznych pozyskanych w kanale tłocznym pompy oleju. Jako uogólniony parametr stanu technicznego badanego układu hydraulicznego przyjęto zmianę: ciśnień i jego amplitud zarejestrowanych podczas ruchów roboczych układu, czasu ruchu roboczego tłoczyska siłownika oraz temperatury czynnika roboczego.
EN
The method of identification of the technical state of the hydraulic system on the base of the analysis of dynamic characteristics acquired in the pumping conduit of the oil pump was presented in the paper. As a generalized parameter of the technical state of the investigated hydraulic system there was assumed the change of: pressures and their amplitudes recorded during activity of the system, activity time of the piston rod of the hydraulic cylinder, temperature of the working fluid.
EN
The aim of this study was to determine the expression of Ki-67 and PCNA proliferative antigens and the apoptotic index in dogs with various degrees of severity of inflammatory bowel disease (IBD), and to evaluate the applicability of these markers in diagnosing the disease. The study was performed on 28 dogs of different breeds, both sexes, with body weights of 10 to 20 kg, aged 2 to 10 years. The animals diagnosed with IBD were divided into four groups of 7 dogs each, including three groups characterized by various degrees of severity of IBD and a control group. The expression of Ki-67 and PCNA antigens was determined immunohistochemically, and the apoptotic index was expressed as the number of TUNEL-positive lamina propria cells in the duodenum, jejunum and the colon. Regardless of its form, IBD affected the expression of the analyzed proliferation markers and apoptosis in duodenal, jejunal and colonic mucosa, but most of the analyzed parameters were not correlated with the severity of the disease. The severity of IBD was correlated only with the expression of Ki-67 in duodenal villi. The results of the study point to the limited applicability PCNA and the apoptotic index in differentiating and evaluating the progression of IBD in dogs. The estimation of Ki-67 expression may be useful in the evaluation of the severity of IBD in dogs.
12
51%
EN
The treatment of inflammatory bowel disease (IBD) possesses numerous difficulties owing to the unclear etiology of the disease. This article overviews the drugs used in the treatment of IBD depending on the intensity of clinical symptoms (Canine Inflammatory Bowel Disease Activity Index and Canine Chronic Enterophaty Clinical Activity Index). Patients demonstrating mild symptoms of the disease are usually placed on an appropriate diet which may be combined with immunomodulative or probiotic treatment. In moderate progression of IBD, 5-aminosalicylic acid (mesalazine or olsalazine) derivatives may be administered. Patients showing severe symptoms of the disease are usually treated with immunosuppressive drugs, antibiotics and elimination diet. Since the immune system plays an important role in the pathogenesis of the disease, the advancements in biological therapy research will contribute to the progress in the treatment of canine and feline IBD in the coming years.
EN
This study evaluates the efficacy of budesonide in the treatment of inflammatory bowel disease (IBD) in dogs based on the results of clinical, endoscopic and histopathological examinations. The severity of clinical symptoms was assessed based on CIBDAI scores, and macroscopic and histopathological changes were described in accordance with the recommendations of the WSAVA Gastrointestinal Standardization Group for 2008. The results of the experiment revealed that budesonide does not offer effective treatment for canine IBD. The tested drug failed to alleviate the clinical symptoms of disease, lower CIBDAI scores, or improve the macroscopic appearance of intestinal mucosa. The effectiveness of budesonide was most highly evaluated in the histopathological picture of duodenal, jejunal and colonic mucosa.
EN
Contrast-enhanced ultrasonography is mainly used in heart examination and to detect and characterize focal liver lesions. CEUS also allows the evaluation of the spleen, pancreas, kidneys, lymph nodes and the detection of porto-systemic shunts. UCAs can be administered intracavitarily, e.g. in the urinary bladder. In human medicine CEUS is used in the assessment of anti-angiogenic treatment. In some cases concerning the detection and characterization of focal lesions in such organs as the liver, spleen and kidneys, CEUS is equally or more efficient than CECT. The advantages of CEUS are: non-invasiveness, high availability, short examination time, low cost expenses and good patient tolerance compared to contrast agents use in CECT and CEMRI. The appearance of UCAs decreased the gap dividing the diagnostic value of USG and CT/MRI and also allows the characterization of neoplastic lesions without the need of invasion biopsy and diagnostic laparatomy.
EN
Ultrasonography is an imaging technique universally employed in veterinary medicine. It has many advantages, such as high availability, non-invasiveness, short examination time, no anesthesia, and low cost, but also some drawbacks, like low specificity. To overcome these limitations, ultrasound contrast agents (UCAs) and specific ultrasound contrast techniques have been developed. The application of UCAs and specific sonographic contrast techniques increase the specificity and sensitivity of ultrasound examination. Nowadays the new contrast-specific imaging techniques enable the separation of the linear tissue signal from the non-linear microbubble signal, which, combined with the introduction of second-generation UCAs, makes contrast-enhanced ultrasonography a very important diagnostic tool.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.