This paper presents an evaluation of the Hypoplastic Clay constitutive model for finite element analysis of deep excavations and displacements induced by excavations in the influence zone. A detailed description and formulation of the Hypoplastic Clay soil model is included. A parametric case study of a deep excavation executed in Pliocene clays is presented. FE analysis was performed using several soil models (Mohr-Coulomb, Modified Mohr-Coulomb, Drucker-Prager, Modified Cam-Clay, Hypoplastic Clay) and the results were compared to in-situ displacements measurements taken during construction. Final conclusions concerning the suitability of the Hypoplastic Clay model for deep excavation modelling in terms of accurate determination of horizontal displacements of the excavation wall, the uplift of the bottom of excavation, and, most importantly,vertical displacements of the terrain in the vicinity of the excavation are presented.
PL
W artykule przedstawiono ocenę modelu konstytutywnego stanu krytycznego Hypoplastic Clay (Ił hypoplastyczny) do analizy metodą elementów skończonych głębokich wykopów i oceny przemieszczeń w strefie ich wpływu. W pracy zawarto również szczegółowy opis i sformułowanie modelu Hypoplastic Clay. Zaprezentowano parametryczne studium przypadku dotyczące głębokiego wykopu wykonanego w Warszawie, w iłach plioceńskich formacji poznańskiej. Analizowany obiekt to wykop stacji metra o wymiarach 20x150m i głębokości 14.6m wykonywany metodą odkrywkową z zastosowaniem dwóch rzędów kotew iniekcyjnych i jednego poziomu rozpór stalowych jako rozparcia. Analizę modelu przeprowadzono z zastosowaniem metody elementów skończonych, programem GEO5 MES, z uwzględnieniem kilku modeli materiałowych gruntu (Mohr-Coulomb, Modified Mohr-Coulomb, Drucker-Prager, Modified Cam-Clay, Hypoplastic Clay), a wyniki porównano z geodezyjnymi pomiarami przemieszczeń in-situ wykonanymi w trakcie budowy.
W artykule omówiono przykład analizy statycznej ściany głębokiego wykopu stacji metra w Warszawie z zastosowaniem metody parć zależnych. Wartości modułu reakcji podłoża określano z zastosowaniem teorii Chadeissona [1]. Obliczenia przeprowadzono programem GEO5 Ściana analiza.
EN
The article discusses an example of static analysis of a deep excavation wall of an underground railway station in Warsaw using the dependent pressures method. The soil reaction module values were determined according to Chadeisson. The calculations were carried out with GE05 Sciana analiza (Wall analysis) programme.
W artykule przedstawiono przykład analizy numerycznej MES wzajemnego oddziaływania tuneli komunikacyjnych drążonych tarczą TBM i projektowanego obiektu biurowego z parkingiem podziemnym posadowionego 1,4 m nad tunelami. Przedstawiono założenia obliczeniowe i omówiono wyniki obliczeń czterech wariantów (modeli) uwzględniających różnicowanie sposobu wzmocnienia gruntu pod budynkiem. Analizie poddano też osiadania płyty fundamentowej budynku i przemieszczenia stropu tunelu.
EN
The paper presents an example of numerical FEM analysis of the interaction of communication tunnels constructed using TBM and the designed office building with underground parking located 1,4 m above the tunnels. The four models taking into account the differentiation of soil strengthening methods under the building were analyzed. Settlements of the foundation slab of the building and displacement of the top vault of the tunnel are compared for each model and discussed.
Przedstawiono przykład zastosowania analizy MES 3D do projektowania płyty fundamentowej wieżowca współpracującej z rusztem palowym. Celem analizy była weryfikacja obliczeń analitycznych pod kątem redukcji kosztów posadowienia. Dzięki realistycznemu trójwymiarowemu modelowi, w którym było możliwe uwzględnienie sztywności rusztu palowego oraz konstrukcji podziemia w pracy fundamentu, potwierdzono możliwość skrócenia pali o około 20%.
EN
The paper presents 3D finite element analysis of piled raft foundation. Reduction of overall project costs was the main aim of the analysis. Calculations proved that 20% reduction in pile length is possible. This conclusion could be reached thanks to the realistic modelling of the added stiffness from the raft and super structure made possible by 3D finite element analysis.