Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
2
Content available remote Pojęcie ryzyka : wprowadzenie do zasad zarządzania ryzykiem
100%
|
|
tom nr 2(71)
223-235
EN
The popularization of terms related to risk and uncertainty constitutes one of the ways to modernize the management. Current scientific achievements allow matching to every form of organization the most useful methods and tools for analyzing the symptoms of threat and evaluating the chances to manage risk. In the organizational units (entities), information management based on the feedback devices enables the application of the effective risk management strategies.
PL
Celem artykułu jest ocena aktualnie stosowanych w projektowaniu metod doboru wodomierzy oraz średnic przyłączy wodociągowych w świetle pomiarów rzeczywistego zużycia wody w instalacji wodociągowej w wybranym budynku. Obiektem badań jest wielorodzinny budynek mieszkalny, zlokalizowany w północnej części miasta Krakowa. Zakres pracy obejmuje analizę godzinowego i sekundowego zużycia wody przez mieszkańców budynku oraz weryfikację poprawności doboru aktualnie funkcjonującego wodomierza, a także średnicy przyłącza wodociągowego. Ocenie poddano trzy stosowane w Krakowie metody doboru tych dwóch elementów instalacji wodociągowej na podstawie rzeczywistych pomiarów zużycia wody. Przeprowadzone badania wykazały, iż żadna z analizowanych metod doboru średnicy wodomierza, jak również przyłącza wodociągowego, nie pozwala na uzyskanie wyników w pełni zgodnych z rzeczywistymi przepływami zużywanej wody. Zaobserwowane i zarejestrowane rzeczywiste przepływy wody w budynku były nawet 15-krotnie niższe, niż niektóre przepływy ustalone obliczeniowo. W przypadku każdej z analizowanych metod obliczeniowych stwierdzono przewymiarowanie zarówno średnicy wodomierza, jak również średnicy przyłącza wodociągowego. Istotna rozbieżność pomiędzy parametrami obliczonymi, a empirycznymi, wskazuje na konieczność udoskonalenia metod obliczeniowych doboru wodomierzy oraz średnic przyłączy wodociągowych.
EN
The aim of the following paper is to evaluate methods of water meter selection and diameters of sewer connections currently used in designing in the light of measurements of water actual consumption in water supply system in selected building. The object of the research is multi-family residential building situated in northern Krakow. The scope of work includes the analysis of water consumption per hour and per second by residents of the building and verification of the correct selection of currently functioning water meter and diameter of sewer connection. Three methods used for the selection of these two elements of water supply system in Krakow based on the actual measurements of water consumption have been evaluated. The research has shown that none of the analysed methods of water meter diameter selection as well as sewer connection allow to achieve results completely consistent with the actual flow rate of water consumption. Observed and registered actual water flows in the building have been up to 15 times lower than some design flows. Oversizing of both water meter diameter and sewer connection diameter has been found for each of the analysed measurement methods. A significant discrepancy between measured and empirical parameters indicates the need to improve measurement methods for the selection of water meters and diameters of sewer connections.
|
|
tom nr IV/3
1661--1672
EN
The objective of this research was to compare the amount of extraneous water flowing into selected gravitational separate sewer systems which discharge domestic sewage from the settlement of single-family houses in Poland and France during a year with a standard annual amount of precipitation. The study included a total of four sewer systems, including two operating in Poland and discharging the sewage from settlements near Krakow in the Malopolska Province and two systems operating in France and discharging the sewage from settlements of single-family houses near Lorient, Brittany, Morbihan Department. As part of the analysis, an average daily tributaries of extraneous water into sewers under the research, values of addition and share of this water were compared. Analysis of the research results demonstrated that the hydraulic load of sewer systems with extraneous water does not depend on the age of the sewer system, but mainly on the number of house drains, and to a lesser extent its length. It was also determined that the average daily amount of extraneous water flowing into sanitary sewer systems in wet weather is 0,107 m3 ·d-1 per 1 sewer connection. The study showed that tributaries of extraneous water into the separate sewer system occurring during the intense precipitation are a major operating problem both in Poland and France.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.