Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Creating luminous environment in interior
100%
|
|
tom R. 84, nr 8
154-157
EN
In this paper ways of illumination and lighting characteristics of luminous environment, at which desired impressions occur, are presented. Opportunities of creating different luminous environments in an exemplary experimental room (virtual conference room) were analyzed. Different luminous environments were achieved with the use of general lighting luminaires. Opportunities of changing the luminous environment in the range of distributions and levels of luminance, and colour of light, were also presented.
PL
W artykule przedstawiono sposoby oświetlania i uzyskiwane cechy oświetlenia, przy których wystąpią określone, oczekiwane odczucia. Zaprezentowano możliwości kreowania różnych otoczeń świetlnych w przykładowym, wirtualnym pomieszczeniu eksperymentalnym typu sala konferencyjna. Różne otoczenia świetlne uzyskano wykorzystując oprawy oświetlenia ogólnego. Przedstawiono możliwości zmian otoczenia świetlnego w zakresie rozkładów i poziomów luminancji oraz barwy światła.
2
Content available remote System oceny wydajności energetycznej oświetlenia wnętrz
100%
|
|
tom R. 85, nr 11
233-236
PL
W artykule przedstawiono autorskie klasyfikacje wydajności energetycznej oświetlenia wnętrz. Wskazano referencyjne poziomy mocy i energii jednostkowej skorygowanej do oceny wydajności energetycznej oświetlenia wnętrz w budynkach użyteczności publicznej. Przedstawiono propozycję systemu oceny wydajności energetycznej oświetlenia wnętrz w budynkach użyteczności publicznej.
EN
In this paper the authors classifications of lighting energy efficiency in interiors were introduced. Reference levels of power and energy densities per 100 lx to assess the lighting energy efficiency in public buildings were indicated. The proposal of the system to evaluate lighting energy efficiency of interiors in public buildings was introduced too.
3
Content available remote Dynamika energetyczna oświetlenia
100%
|
|
tom R. 86, nr 3
290-292
PL
W artykule opisano miary dynamiki energetycznej oświetlenia. Analizowano odniesieniowe czasy użytkowania wnętrzowych i drogowych urządzeń oświetleniowych. Dla zmiennych wartości parametrów charakteryzujących potencjał energetyczny oświetlenia i przyjętych czasów odniesieniowych, wyznaczono zakresy wartości energii jednostkowych i energii jednostkowych skorygowanych wnętrzowych i drogowych urządzeń oświetleniowych.
EN
In this paper measures of lighting energy dynamics were characterised. Reference periods of operation of both interior and road lighting installations were analysed. For combination of the parameters characterising lighting energy potential and the times taken the values of both interior and road lighting energy densities and energy densities per 100 lx or 1 cd/m2 were calculated.
5
Content available remote The use of different metrics for the evaluation of road lighting energy efficiency
100%
|
|
tom R. 92, nr 2
224--228
EN
This paper tackles the issue of the road lighting energy efficiency. The levels of the normalised power density, the normalised power per road length, the normalised energy density and the normalised energy per road length for road lighting situations were calculated. Levels of these parameters represent the potential ranges of typical road lighting situations. The use of different metrics for the accurate evaluation of road lighting energy efficiency is essential and only the evaluation based on different metrics gives the opportunity to select rational lighting solutions for roads.
PL
Artykuł porusza problematykę efektywności energetycznej oświetlenia drogowego. Wyznaczono poziomy różnych miar efektywności energetycznej oświetlenia drogowego: moc jednostkową, moc jednostkową na jednostkę długości jezdni, energię jednostkową i energię jednostkową na jednostkę długości jezdni. Poziomy tych parametrów reprezentują typowe zakresy dla sytuacji oświetlenia drogowego. Wykorzystanie różnych miar do dokładnej oceny efektywności energetycznej oświetlenia drogowego jest koniecznością i tylko w takim przypadku prowadzi do wyboru racjonalnych rozwiązań oświetlenia drogowego.
|
|
tom R. 85, nr 11
237-241
PL
W pomieszczeniach z oknami można oczekiwać oszczędności w zużyciu energii elektrycznej. Na Słowacji jest obowiązek wykonywania obliczeń oświetlenia dziennego i elektrycznego, a także zużycia energii elektrycznej na potrzeby oświetlenia. W Polsce jest obowiązek wykonywania obliczeń oświetlenia elektrycznego i zużycia energii elektrycznej na potrzeby oświetlenia do celów certyfikacji budynków. Kryteria projektowania oświetlenia dziennego i elektrycznego uwzględniają wymagania higieniczne, natomiast w kryteriach wydajności energetycznej potrzeby wzrokowe są zmarginalizowane. W artykule poruszono zagadnienia związane z kryteriami projektowania oświetlenia wnętrz.
EN
The electric energy can be saved in rooms with properly designed windows. Daylighting, artificial lighting design and energy performance of building are required after standards in Slovakia. Only artificial lighting design and energy performance of buildings are estimated via certification in Poland. Criteria of daylighting and artificial lighting guarantee minimal hygienic requirements while after energy performance criteria indoors are illuminated without visual task requirements. This paper discusses illumination conditions, requirements and criteria.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.