Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The corrosion properties of Ti-6Al-4V alloy with oxynitride coatings formed by both the low-temperature oxidation and the subsequent high-temperature oxidation of pre-formed nitride coatings were investigated in a simulated body fluid (Ringer's solution) at the temperatures of 36оС and 40оС. The modification by oxygen of the nitride coating formed at pN2 = 1 Pа improves the corrosion resistance of Ti-6Al-4V alloy in the solution at both temperatures. At the same time the modified by oxygen nitride coatings formed at pN2 = 105 Pа show worse corrosion protection than nitride coatings. At both temperatures of Ringer's solution the oxynitride coating provides Ti-6Al-4V alloy the better corrosion resistance at higher content of oxygen in a composition of titanium oxynitride. By increasing the temperature of the solution from 36оС to 40оС the corrosion protection of the alloy by oxynitride coatings is somewhat reduced.
PL
Zbadano w roztworze Ringera w temperaturze 36оС i 40оС właściwości korozyjne stopu Ti-6Al-4V z powłokami tlenoazotkowymi utworzonymi przez utlenianie w niskiej temperaturze i następne utlenianie w wysokiej temperaturze wstępnie uformowanych powłok azotku. Modyfikacja tlenem powłoki utworzonej z azotku przy pN2 =1 Pа polepsza odporność na korozję stopu Ti-6Al-4V w roztworze Ringera w obu temperaturach. W tym samym czasie modyfikacji tlenem powłoka azotku utworzona przy pN2 = 105 Pа wykazuje gorszą ochronę przed korozją niż powłoki azotkowe. W obu temperaturach roztworu Ringera powłoka tlenoazotkowa zapewnia stopowi Ti-6Al-4V lepszą odporność na korozję przy wyższej zawartości tlenu w tlenoazotku tytanu. Poprzez podwyższenie temperatury roztworu z 36оС do 40оС zabezpieczenie antykorozyjne stopu powłokami tlenoazotkowymi jest nieznacznie zmniejszone.
EN
An advance in the material engineering of biomaterials intended for hip joint replacement prostheses is a very important social matter due to incurable diseases or injuries of human joints happening to many people. For this purpose, a development of the tribological test techniques is also an urgent issue. The paper is devoted to the study of the tribological behaviour of the new “Nitrided GRADE 2/PE-UHMW” friction pair intended for hip joint endoprostheses. A pendulum tribometer and a ring-on-plane machine were used for tribological research. A new lubricant based on chondroitin sulphate was tribologically investigated compared to commonly used bovine blood serum. Also the technology of thermo-diffusion nitriding (TDN) of the GRADE 2 femoral head was optimised based on the results of the tribological experiments. A means of selecting of the geometrical parameters of the prosthetic implants to achieve the smallest wear is discussed. The optimum technology of machining of the femoral head made of the GRADE 2 titanium alloy to obtain the best surface quality is also presented. The paper consists of the first part of the results of the Polish-Ukrainian cooperation in testing biomaterials. The second part, to be also submitted to Tribologia, will describe the aspects of methodology of endoprosthesis simulation tests and test results, and it will present a difference in the wear of the hip joint prosthesis – the developed and commercial one.
PL
Postęp w inżynierii materiałowej biomateriałów stosowanych w endoprotezach stawu biodrowego jest bardzo ważną sprawą społeczną z powodu nieuleczalnych chorób lub urazów stawów ludzkich, które zdarzają się wielu osobom. W tym celu pilną kwestią jest także rozwój tribologicznych technik badawczych. Artykuł poświęcony jest badaniu właściwości tribologicznych nowej pary trącej nazwanej „Nitrided GRADE 2/PE-UHMW”, przeznaczonej na endoprotezy stawu biodrowego. Do badań tribologicznych wykorzystano tribometr wahadłowy i maszynę typu pierścień–płaszczyzna. Nowy smar na bazie siarczanu chondroityny został poddany badaniom tribologicznym i porównany do powszechnie stosowanej surowicy krwi bydlęcej. Również technologia azotowania termodyfuzyjnego (TDN) główki endoprotezy (GRADE 2) została zoptymalizowana w oparciu o wyniki eksperymentów tribologicznych. Omówiono sposób doboru parametrów geometrycznych implantów protetycznych w celu osiągnięcia najmniejszego zużycia. Przedstawiono również optymalną technologię obróbki głowicy endoprotezy wykonanej ze stopu tytanu (GRADE 2) w celu uzyskania najlepszej jakości powierzchni. Artykuł zawiera pierwszą część wyników uzyskanych w ramach polsko-ukraińskiej współpracy w zakresie badania biomateriałów. W drugiej części, która również jest planowana do publikacji w czasopiśmie Tribologia, zostaną opisane aspekty metodologii testów symulacyjnych endoprotez i wyniki badań oraz przedstawiona różnica w zużyciu endoprotezy stawu biodrowego – opracowanej i handlowej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.