The corrugated plate steel shear walls (CSPWs) are widely used as lateral force resistant members in high-rise buildings. However, buckling failure still easily occurred on corrugated steel plates subjected to earthquake loads, which is not good for the energy dissipation of structures. In this paper, the asymmetric diagonal stiffened beam-only-connected corrugated steel plate shear wall (ASW) is proposed. A test-validated FE modeling method is used to investigate the seismic performance of ASW, and the results are compared with the results of unstiffened corrugated steel plate shear wall (USW). Then parametric studies on the height-to-thickness ratio, wavelength, wave height of the corrugated plate and width-to-thickness ratio of the stiffeners are performed to investigate their effects on the seismic performance of ASW. Finally, a simplified theoretical model is developed to calculate the shear resistance of ASW, and the results are validated by tests and FE results. The results show that: (1) compared to the USW, the yield load and ultimate load of ASW increase 11.7% and 13.2%, respectively; (2) the theoretical calculation results are basically consistent with the FE and test results, and the errors between them are within ± 15%. These results can be used for seismic enhancement of CSPWs and seismic design of ASW.