Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
|
|
tom Vol. 44, nr 4
647-655
EN
The AlGaAs/GaAs heterostructure PIN photodiodes, grown by molecular beam epitaxy, are evaluated for the measurement of laser pulses and X-ray diagnostics of laser-induced plasmas. Excitation by the 820 nm laser pulses yields rise time of the detector less than 200 ps. The device is sensitive to 1.06 µm pulses from the Nd:YAG laser. Also α-particle spectra are measured and interpreted. The detector is able to operate at zero bias. Theoretical response to X-rays is calculated.
PL
W pracy oceniono możliwość zastosowania fotodiodowej, epitaksialnej struktury p-i-n AIGaAs/GaAs do pomiaru impulsów laserowych i impulsów promieniowania X z plazmy laserowej. Przeprowadzone zostały testy struktur próbnych za pomocą impulsów światła z diody laserowej (820 nm), z lasera Nd:YAG (1,06 µm) oraz z użyciem źródła cząstek α (241Am). Stwierdzono, że detektory mogą pracować z zerowym napięciem polaryzacji. Czas narastania impulsów wyjściowych wynosił mniej niż 200 ps. Dla pełnej oceny możliwości detekcyjnych wykonano obliczenia wydajności detektorów na promieniowanie X dla różnych wariantów struktury powierzchniowej.
EN
The electron-beam-induced current (EBIC) method is employed to study the boundary effects of the commercial BPYP and BPYP 42 photodiodes, aiming at a better understanding of their response to α-particle and light-pulse excitation. Our results show that the EBIC method is suitable for the assessment of photodetectors for X-ray detector applications. The sensitivities of different detector areas are quantitatively assessed. A good agreement is found with pulse-height spectra measurements. The complementary nature of electron-beam and light-pulsed/a-particle excitation is pointed out.
PL
Metoda pomiaru prądów indukowanych wiązką elektronową (EBIC) została zastosowana do badania wpływu efektów brzegowych na działanie fotodiod BPYP 44 i BPYP 42 użytych do detekcji impulsów promieniowania X emitowanego z plazmy laserowej. Dodatkowym celem pracy było wyjaśnienie nietypowych efektów obserwowanych podczas detekcji impulsów światła i cząstek α. Stwierdzono, że wnioski dotyczące funkcjonowania fotodiod, otrzymywane za pomocą różnych metod stymulacji, wzajemnie się potwierdzają i uzupełniają. Na ich podstawie można ocenić wkład poszczególnych obszarów powierzchniowych struktur do odpowiedzi detektorów na impuls promieniowania X.
EN
A compact, three-channel, noise-resistant detection head based on semiconductor detectors has been built for the diagnostics of X-ray emission from plasmas. It is useful in the energy range of 0.5–20 keV.
4
Content available remote High-intensity interaction of picosecond laser pulses with metal target.
61%
EN
The results of experimental investigation of the interaction of picosecond light pulses with a Cu target at light intensities up to 3.10/sup 16/ W/cm/sup 2/ are presented and discussed. The experiment was performed with the use of a terawatt chirped-pulse-amplification Nd:glass laser and the apparatus for corpuscular (ion collectors, electrostatic ion energy analyser) and X-ray (p-i-n Si photodiode) diagnostics of laser-produced plasma. The charge spectra of ions emitted from a picosecond plasma as well as the energy-dependent (or intensity-dependent) characteristics of ion emission and soft X-ray yield are determined. The electron temperature and the average charge state of the plasma are evaluated as a function of light intensity.
EN
The results of comparison of X-ray emission from plasmas produced by 1-ps and 0.5-ns laser pulses from massive and foil targets are reported. The measurements were performed for the soft (0.8-1.6 keV) and hard (4-30 keV) X-rays with the use of filtered p-i-n Si photodiodes at laser intensities of up to 10/sup 17/ W/cm/sup 2/ for ps pulses and up to 3 * 10/sup 14/ W/cm/sup 2/ for sub-ns ones. The effect of the laser pulse duration on the X-ray yields for various laser beam focal spots, laser pulse energies and atomic numbers of the targets were investigated.
EN
The purpose of this paper is to present the newly-opened High Power Laser Laboratory (HPLL) at the Institute of Plasma Physics and Laser Microfusion (IPPLM). This article describes the laser, the main laboratory accessories and the diagnostic instruments. We also present preliminary results of the first experiment on ion and X-ray generation from laser-produced plasma that has been already performed at the HPLL.
EN
Thermoluminescent and semiconductor detectors operating in an integrating mode have been applied to the measurement of X-ray flashes of high intensity from large plasma facilities. A detection head of special kind has been developed to perform comparison measurements with the use of the detectors of both kinds.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.