In this paper, flow systems which are commonly used in fittings elements such as contractions in ice slurry pipelines, are experimentally investigated. In the study reported in this paper, the consideration was given to the specific features of the ice slurry flow in which the flow behaviour depends mainly on the volume fraction of solid particles. The results of the experimental studies on the flow resistance, presented herein, enabled to determine the loss coefficient during the ice slurry flow through the sudden pipe contraction. The mass fraction of solid particles in the slurry ranged from 5 to 30%. The experimental studies were conducted on a few variants of the most common contractions of copper pipes: 28/22 mm, 28/18 mm, 28/15 mm, 22/18 mm, 22/15 mm and 18/15 mm. The recommended (with respect to minimal flow resistance) range of the Reynolds number (Re about 3000-4000) for the ice slurry flow through sudden contractions was presented in this paper.
PL
Przedmiotem badań doświadczalnych, zaprezentowanych w pracy, są procesy przepływowe zachodzące w powszechnie stosowanych elementach armatury, jakimi są redukcje średnicy rurociągu, w których przepływa lód zawiesinowy. Wyniki badań eksperymentalnych, zamieszczonych w pracy, uwzględniają specyficzne cechy przepływu lodu zawiesinowego, który jest mieszaniną roztworu alkoholu etylowego i drobinek lodu.
EN
Experimental investigations on flow of slurry ice in common used pipe reductions are presented in the paper. The results of experimental investigations contain specific flow characters of slurry ice as a mixture of water solution of ethylene alcohol and ice crystals.
3
Content available remote Resistance coefficient during ice slurry flow through pipe sudden constriction
100%
EN
Due to the adverse environmental effects of some commonly-used refrigerants, efforts are still underway to find new cooling mediums that would be safer to the ozone layer and would not increase the greenhouse effect. Ice slurry as a new ecological coolant suits the processes requiring the preservation of constant and equal temperature in the cooling process of the full section of the cooled solid. Thanks to that, ice slurry can find a wide potential application in such branches of industry, as heat treatment, materials engineering, or foundry. In this paper, flow systems which are commonly used in fittings elements such as diameter’s reductions in ice slurry pipelines, are experimentally investigated. In the study reported in this paper, the consideration was given to the specific features of the slurry flow in which the flow qualities depend mainly on the volume fraction of solid particles. The results of the experimental studies on the flow resistance, presented herein, enabled to determine the resistance coefficient during the ice slurry flow through the pipe sudden constriction. The volume fraction of solid particles in the slurry ranged from 5 to 30%. The recommended and non-recommended range of the Reynolds number for the ice slurry flow through the pipe sudden constriction were presented in this paper. The experimental studies were conducted on a few variants of the most common reductions of copper pipes. Further studies on the determination of the resistance coefficient in the remaining fittings elements of the pipeline were recommended in the paper as well as the further theoretical studies intended to determine the theoretical relations to calculate the resistance coefficient in all the fittings elements in the pipeline (on the basis of the experimental studies) and to elaborate the calculation pattern of the entire ice slurry system.
PL
W artykule zaprezentowano różne aspekty zastosowania absorpcyjnych urządzeń chłodniczych w świetle integracji z Unią Europejską. Zamieszczono przykłady zastosowań tych urządzeń, a także zalety w porównaniu do urządzeń sprężarkowych.
EN
In the article was presented different aspects application absorption refrigerators in the background integration with European Union. There were shown examples application those systems, way of working and advantages in comparision to refrigerating compressors systems.
PL
W pracy przedstawiono oryginalne wyniki badań doświadczalnych współczynnika strat miejscowych dla zawiesiny lodowej, o udziałach drobinek lodu 5-30%, podczas przepływu przez kilka rodzajów nagłych zwężeń rury w odniesieniu do wyników obliczeń teoretycznych. W pracy wskazano także zalecane i niezalecane zakresy liczby Reynoldsa dla przepływu zawiesiny przez nagłe zwężenia rury. W pracy pokazano także zakresy przepływu, w których wartość współczynnika strat miejscowych zależy od liczby Reynoldsa.
EN
The experimental results of resistance coefficient measurements were presented in the paper. Investigations were carried out with slurry ice flow (concentration of 5-30%) in several kinds of pipe sudden contractions. The experimental and theoretical results were compared. The recommended and not recommended Reynolds number of slurry ice flow in pipe sudden contractions based on experimental results were presented. It was shown that the flow zone defined by resistance coefficient depends on the Reynolds number.
PL
W artykule zaprezentowano opis wybranych odpadowych i odnawialnych źródeł ciepła. Przedstawiono projekt instalacji z pompą ciepła, wykorzystującą ciepło zawarte w ściekach, służącej do ogrzewania pomieszczenia gastronomicznego.
EN
In the article description of selected waste and renewable heat source ware presented. There were shown project of instalation, with heat pump, which is using warmth from liquid wastes to heat gastronomy room.
EN
In the paper the assessment of using slurry ice as cooling medium in indirect cooling systems were presented. On the basis of experimental results and calculations a comparative analysis between slurry ice made of 10% ethyl alcohol and traditionally used cooling media was done.
EN
The primary aim of this paper was to assess the development of prosumer energy sector in Poland. In the first point, the basic notions connected with prosumer energy (micro-installation, prosumer) were discussed on the basis of Law of Renewable Energy Sources of February 20, 2015 (Journal of Laws, item 478, as amended) and the main aspects of the European Union energy policy where presented in the context of the development of the prosumer energy sector. In this part of the study, numerous benefits for the Polish economy and consumers of electrical energy, connected with the expansion of prosumer energy sector, were presented. On the other hand, many obstacles which stall this sector in Poland were noticed. In the second point the most important regulations from the Law of Renewable Energy Sources of February 20, 2015 were analyzed (In the second point the most important regulations from the Law of Renewable Energy Sources of February 20, 2015 (hereinafter: the RES act) were analyzed). On the basis of this legal act, the so called “rebate system”, which is currently used in Poland to support prosumers of electrical energy, was described. Moreover, many legal and administrative simplifications implemented by the RES act were indicated. The analytical approach to the RES Act in this study resulted in the detection of many regulations in this legal act which may have an adverse impact on the development of the prosumer energy sector in Poland. In the third point, programs co-financed by the Polish government or the European Union, which financially support the purchase and installation of energy technologies using RES, were described. Statistical data connected with the prosumer energy sector in Poland was presented in the fourth point of this paper. On the basis thereof, the authors attempted to find the correlation between the number of prosumers and the share of the amount of electrical energy from renewable energy sources in gross electrical energy consumption. In the fifth point issues connected with energy technologies used in the Polish prosumer energy sector were discussed. Moreover, this point focuses on the great popularity of photovoltaic modules among Polish prosumers and results in the reluctance of Polish prosumers to install wind microturbines and small hydroelectric power plants.
PL
Podstawowym celem artykułu była ocena stanu rozwoju energetyki prosumenckiej w Polsce. W rozdziale pierwszym omówiono podstawowe pojęcia związane z energetyką prosumencką (mikroinstalacja, prosument), które zostały zdefiniowane w Ustawie o odnawialnych źródłach energii z dnia 20 lutego 2015 r. (Dz.U. poz. 478 ze zm.) oraz odniesiono się do polityki energetycznej Unii Europejskiej w kontekście rozwoju prosumenckiego modelu energetyki. W tej części pracy wskazano liczne korzyści dla polskiej gospodarki oraz konsumentów energii elektrycznej wynikające z rozwoju prosumeryzmu w polskiej energetyce, ale również zwrócono uwagę na bariery, które nadal stoją na drodze rozwoju energetyki prosumenckiej w naszym kraju. W rozdziale drugim dokonano wykładni fundamentalnych przepisów ustawy o odnawialnych źródłach energii z dnia 20 lutego 2015 r. (Dz.U. poz. 478 ze zm.; dalej: ustawa o OZE). Na ich podstawie omówiono system upustów, będący obecnie stosowanym w polskim porządku prawnym system wsparcia prosumentów. Wskazano także liczne uproszczenia administracyjno-prawne wynikające z zapisów wspomnianej ustawy o OZE. Krytyczne podejście do ustawy o OZE pozwoliło na uwypuklenie niekorzystnych lub nieprecyzyjnych przepisów w kontekście rozwoju prosumenckiego modelu energetyki. W rozdziale trzecim opisano programy dofinansowania wspierające rozwój energetyki prosumenckiej w Polsce, poprzez partycypowanie w kosztach zakupu i montażu mikroinstalacji. Dane liczbowe charakteryzujące stan energetyki prosumenckiej w naszym kraju zawarto w rozdziale 4. Na ich podstawie podjęto również próbę omówienia zależności pomiędzy liczbą prosumentów a udziałem energii elektrycznej z odnawialnych źródeł w całkowitej jej konsumpcji. W rozdziale piątym pochylono się nad technologiami energetycznymi wykorzystywanymi w energetyce prosumenckiej w Polsce. Wskazano w nim przyczyny dużej popularności paneli fotowoltaicznych wśród polskich prosumnetów, przy niskim zainteresowaniu mikroturbinami wiatrowymi i małymi elektrowniami wodnymi.
PL
W artykule zaprezentowano nowe chłodziwo, jakim jest lód binarny (zawiesinowy). Dokonano ogólnego opisu tego chłodziwa oraz omówiono jego zalety i wady w stosunku do tradycyjnie stosowanych: wody i solanek. Przedstawiono różne sposoby pomiaru zawartości lodu zawiesinowego.
EN
Binary ice - a new cooling medium has been presented in the paper. Its advantages and disadvantages, compared to water and brines used traditionally, have been described. Also varioous methods for the measurement of binary ice content have been shown.
PL
W projekcie ATLAS realizowanym w akceleratorze LHC w laboratorium CERN, do chłodzenia detektorów krzemowych położonych najbliżej punktu zderzeń cząstek zastosowano dwufazowy system chłodzenia. W obszarze fizyki cząstek elementamych jest to pierwsza próba wykorzystania procesu wrzenia do odbioru strumienia ciepła wytwarzanego przez układy detektorów krzemowych. W artykule przedstawiono warunki pracy, zasadę działania i kontroli systemu chłodzenia oraz opisano poszczególne elementy układu chłodzenia detektorów krzemowych z wykorzystaniem wrzącego czynnika chłodniczego.
EN
Two-phase system has been used for cooling of silicon detectors located in a vicinity of the particles collision place under the project ATLAS curred in the accelerator LHC at the CERN laboratory. This is the first atlempt of an application of boiling for removing heat dissipated by systems of silicon detectors in physics of elementary particles. The operation conditions, work principles and control of cooling system as well as the components of the cooling system of silicon detectors using boiling of refrigerant have been described in the paper.
11
63%
EN
The paper presents the results of experimental studies on ice slurry flow resistance in sudden pipe expansions. In the experimental studies, the mass fraction of solid particles in the slurry ranged from 5 to 30%. The pressure loss coefficients identified as a result of the experimental studies of the turbulent flow of the ice slurry are the same as the coefficients calculated for Newtonian liquids.
PL
W artykule przedstawiono wyniki badań współczynnika miejscowych strat ciśnienia przy przepływie zawiesiny lodowej przewodem o nagle zwiększającym się przekroju przepływu. Badania przeprowadzono dla zawiesiny lodowej o udziale masowym lodu od 5 do 30%. Otrzymane z badań wartości współczynników strat miejscowych w turbulentnym zakresie przepływu są zgodne z wartościami tych współczynników obliczonymi jak dla przepływu cieczy newtonowskiej.
PL
W prezentowanych w artykule badaniach dokonano porównania wartości współczynników przejmowania ciepła dla lodu zawiesinowego, obliczonych za pomocą zależności literaturowych z wynikami własnych badań doświadczalnych. Na tej podstawie stwierdzono, że rozbieżności pomiędzy wynikami obliczeń tego współczynnika zależnościami różnych autorów, zamieszczonymi w literaturze są bardzo duże i sięgają nieraz kilkuset procent. Zaproponowano modyfikację wzoru Christensena - Kauffelda na średni współczynnik przejmowania ciepła. Nowe formuły zostały opracowane przez autorów na podstawie wyników własnych badań doświadczalnych prowadzonych dla wymiennika ciepła zbudowanego z czterech wężownic oraz dla wymiennika płytowego.
EN
The comparative analysis of the values of film heat transfer coefficient calculated for binary ice on the basis of the relationships found in the literature and experimental data have been presented in the paper. The authors found that in some cases the discrepancy between experimental data and calculated values are few hundred percents. The authors proposed the modification of the equation of Christensen-Kauffeld for average film heat transfer coefficient. This modification was proposed on the basis of the own experimental data for coil and plate heat exchangers.
13
Content available remote Ścieki - źródło energii niskotemperaturowej dla pomp ciepła
63%
EN
In the article short description of selected waste heat source was presented. There was shown rule of action and project of instalation, with heat pump, which is using warmth from liquid wastes to heat gastronomy room. There were presented advantages coming from using heat pump feeded warmth from liquid wastes.
PL
W pracy przedstawiono porównanie wartości współczynników przejmowania ciepła lodu zawiesinowego obliczonych za pomocą zależności literaturowych z wynikami własnych badań doświadczalnych. Poprzez modyfikację wzoru Christensena-Kauffelda zaproponowano nową formułę obliczeniową na średni współczynnik przejmowania ciepła, opracowaną na podstawie wyników badań eksperymentalnych czterech wężownicowych wymienników ciepła (ożebrowanych oziębiaczy powietrza).
EN
In this paper a comparison of values of heat transfer coefficients of the slurry ice calculated using literaturę formulas and results of experimental investigations was presented. By modification of Christensen-Kauffeld formuła the new formuła to calculation the average heat transfer coefficient was obtain. It was elaborated on the base of experimental investigations of four coil pipes (fined air-coolers).
16
Content available remote Ice slurry flow in ball valves
51%
EN
This paper presents the results of experimental studies of the flow resistance of slurry ice flowing through ball valves. Loss coefficients in ball valves were determined from experimental investigations. The study focused on 1/2”, 3/4” and 1” ball valves at two valve positions (20˚ and 30˚). The ice mass fraction in the studied ice slurry ranged between 5% and 30%.
PL
W pracy przedstawiono wyniki badań doświadczalnych oporów przepływu zawiesiny lodowej w zaworach kulowych. Na podstawie wyników badań doświadczalnych wyznaczono wartości współczynników strat miejscowych w badanych zaworach. W badaniach wykorzystano przelotowe zawory kulowe o średnicach 1/2”, 3/4” oraz 1” przy dwóch pozycjach zamknięcia (20˚ i 30˚). Udziały masowe drobinek lodu w zawiesinie w badaniach wynosiły od 5 do 30%.
PL
Zgodnie z dyrektywą Komisji Europejskiej numer 842/2006 (a później 517/2014) od stycznia 2017 roku zakazano stosowania czynników chłodniczych we wszystkich nowych urządzeniach klimatyzacji samochodowej, dla których wskaźnik GWP, charakteryzujący potencjał tworzenia globalnego ocieplenia, wynosi więcej niż 150. Z tego względu, stosowany powszechnie czynnik R-134a zostaje stopniowo wycofywany z użytkowania. Zaczęto poszukiwania alternatywnego czynnika, który spełni wszystkie wymogi. Według międzynarodowych zaleceń, czynnik powinien posiadać przede wszystkim właściwości przyjazne środowisku oraz powinien być bezpieczny w eksploatacji, nie stanowiąc zagrożenia dla życia ludzkiego. W artykule porównano dwie alternatywne substancje, które w większym lub mniejszym stopniu mogą być zamiennikami czynnika R-134a w układach klimatyzacji pojazdów. Są to syntetycznie otrzymywany czynnik oznaczony symbolem R-1234yf z grupy HFO oraz występujący w środowisku naturalnym dwutlenek węgla CO2 o symbolu R-744. W pracy opisano ich budowę chemiczną, właściwości fizyczne oraz termodynamiczne. Zestawiono publikacje naukowe, uwzględniające wyniki badań doświadczalnych wydajności, osiąganych przez układy chłodnicze, w których stosowano porównywane czynniki. Dokonano opisu metodyki badawczej, scharakteryzowano wykorzystane narzędzia oraz przedstawiono najważniejsze, z punktu widzenia autorów artykułu, wyniki badań. Alternatywne czynniki poddano również analizie środowiskowej. Sprawdzono ich wpływ na degradację warstwy ozonowej oraz scharakteryzowano wskaźnik potencjału tworzenia globalnego ocieplenia. Ponadto przeanalizowano kwestie bezpieczeństwa, zgodnie z obowiązującym normami, pod względem palności, toksyczności, klasyfikując poszczególne czynniki do odpowiednich grup bezpieczeństwa. Omówiono negatywne działania czynników na ludzki organizm, podczas eksploatacji urządzeń napełnionych ocenianymi czynnikami oraz ich awarii. Dokonano krótkiego porównania ekonomicznego, analizując obecne ceny czynników i usług serwisowych.
EN
According to The European Commission’s regulation numbers 842/2006 and 517/2014, refrigerants whose Global Warming Potential ratio is more than 150, have been prohibited in mobile air conditioning (MAC) since January 2017. Therefore, the commonly used R-134 gas has been banned. The search for a new refrigerant, which grants all the required criteria, has begun. In accordance with new European standards, the gas should have environmentally friendly properties and should not be noxious to human life while operating. In this paper, two alternative substances, which can substitute the banned R134a, have been compared. This is synthetic R1234yf, which belongs to the HFO group, and carbon dioxide, which exists in the natural environment. The chemical build, physical and thermodynamic properties have been described. Scientific articles, which present and compare the technical results of testing both refrigerants, have been discussed. Comparison results, tools used and research methodology have been described in these articles. Alternative gases have been analyzed for their environmental impact and have been checked on the toxic, flammable, impact on ozone depletion and global warming. The threats to human life due to the use of the new refrigerants have been reviewed. The thesis also comprises an economical comparison between the two gases. A short review and conclusions have been presented at the end of the article.
18
Content available remote Flow modelling of slurry ice in a control valve
51%
EN
The paper presents the results of simulations of the flow of slurry ice through a control valve. The study focused on a HERZ Strömax-M DN20 control valve. The mass share of ice crystals in the studied slurry ice ranged from 5% to 20%. The results of experimental studies confirmed that the simulations were correct.
PL
W artykule przedstawiono wyniki badań symulacyjnych przepływu zawiesiny lodowej w zaworze regulacyjnym. W badaniach wykorzystano przelotowy zawór regulacyjny DN20 firmy HERZ typu Strömax-M. Udziały masowe drobinek lodu w zawiesinie w badaniach wynosiły od 5 do 20%. Wyniki badań doświadczalnych potwierdziły poprawność wyników badań symulacyjnych.
PL
W pracy przedstawiono wyniki badań doświadczalnych współczynnika przenikania ciepła w płytowym oziębiaczu powietrza. Na ich podstawie opracowano zależność kryterialną na współczynnik przejmowania ciepła od strony powietrza przepływającego pomiędzy płytami o określonej konstrukcji.
EN
In this paper the test results of overall heat transfer coefficient in a plate air cooler is presented. On the base this results, the formula to calculating a heat-transfer coefficient for air flowing between precise construction panels is elaborated.
PL
Substancje z serii R-400 to mieszaniny zeotropowe stosowane jako czynniki robocze w zakresie niskich, średnich oraz wysokich temperatur w urządzeniach sprężarkowych. Mają zastosowanie najczęściej jako czynniki chłodnicze w mroźniach, chłodniach oraz w mniejszych instalacjach chłodniczych. Ponadto, czynniki zeotropowe używane są w pompach ciepła, systemach klimatyzacyjnych oraz agregatach chłodniczych, stosowanych do przewozu produktów o niskiej temperaturze przechowywania. Szeroki zakres aplikacji mieszanin zeotropowych sprawia, że są one intensywnie wykorzystywane w różnych urządzeniach chłodniczych, które podczas eksploatacji mogą być narażone na awarie. Szczególnym przypadkiem awarii jest wyciek czynnika z instalacji. Procedury postępowania podczas usuwania awarii są nieco inne kiedy czynnikiem roboczym jest mieszanina z serii R-400, niż dla substancji jednorodnych, co jest spowodowane odmiennymi właściwościami mieszanin zeotropowych. W artykule poruszono zagadnienie uzupełniania czynników z serii R-400 w instalacji i opisano praktyki stosowane w tym zakresie. Na podstawie analizy możliwości wycieku substancji zeotropowych oraz obowiązujących przepisów, przedstawiono właściwe postępowanie w trakcie usuwania skutków takiej usterki. Ponadto, przedstawiono prawidłową metodę odzysku oraz napełniania instalacji zawierającej czynniki zeotropowe.
EN
R-400 Refrigerants are zeotropic blends which are used in low, middle and high temperature range. They are exploited in carrying freezers, cold stores and cooling systems. Furthermore, zeotropic refrigerants are used in heat pumps, air conditioning systems and chillers. Wide range of application have made them a good choice for all cooling devices, which are exposed for some unexpected damage. Leakage is one of the damages which requires more attention. Compared to homogeneous refrigerants procedures of removing damage are other than procedures used for zeotropic blends. It is caused by various physical properties of these mixtures. The article discusses the leakage of zeotropic mixtures from systems. Current methods of removing leakage were described. Based on analysis of properties of zeotropic blends and actual regulations, the correct solution during repairing were pointed out. Furthermore, this paper presents appropriate methods of recovery and filling R-400 mixtures.