Content available remote The stress state analysis of the high performance heat exchanger
100%
EN
The paper presents the analysis of the stress state in the construction of the high performance heat exchanger with finned elliptical tubes. The thermal computations carried out using the control volume method are introduced and explained. The zones in the construction where the failure is the most probable are presented.
PL
W artykule przedstawiono metodykę oceny stanu wytężenia konstrukcji wysokosprawnego wymiennika ciepła z ożebrowanymi rurami eliptycznymi. Omówiono sposób obliczeń cieplnych z użyciem metody objętości skończonych oraz wskazano miejsca konstrukcji wysokosprawnego wymiennika ciepła, w których prawdopodobieństwo pęknięcia rurek na skutek przekroczenia naprężeń dopuszczalnych jest największe.
|
2012
|
tom Nr 5
112--124
EN
The analysis of the hydraulic and thermal performance of the high performance heat exchanger, with the finned elliptical tubes is presented in this paper. The thermal and hydraulic performance of this type of heat exchangers strongly depends on the flow distribution inside the tubes of heat exchanger. However, due to the compact size of these types of heat exchangers, it is difficult to ensure the uniform flow velocities inside all the tubes. The value of flow velocity influences the heat transfer conditions inside the device. The actual value of the mass flow rate for an individual tube may differ significantly from its designed value. If the differences in the flow velocities inside the tubes are large, then the tubes of heat exchanger are exposed to the significant thermal loads. This can cause the large effort of the tube material and may lead to the fracture of tube due to exceeding the allowable stress limits. In this work, the coupled flow, thermal and structural analyses of the heat exchanger are conducted. The zones and the location of the improper flow conditions are indicated. The structural analysis of the high performance heat exchanger is carried out in order to point out the tubes, where the allowable stresses are exceeded.
PL
W pracy została przedstawiona metodyka obliczeń przepływowo-cieplnych i wytrzymałościowych wysokosprawnego wymiennika ciepła z rurami eliptycznymi ożebrowanymi, o przepływie krzyżowo-prądowym. Wymienniki tego typu stosowane są w instalacjach energetycznych, ciepłowniczych oraz w instalacjach przemysłu ciężkiego. Ulegają one dość często awariom z uwagi na niekorzystne warunki rozpływu czynników roboczych. Jest to uwarunkowane głównie rozwiązaniami konstrukcyjnymi tych wymienników. W pracy pokazano mapy niekorzystnych rozpływów cieczy w wymienniku, otrzymane przy użyciu kodów CFD. Ponadto zamieszczono analizy termiczne i wytrzymałościowe warunków pracy urządzenia, przy użyciu Metody Elementów Skończonych (MES). Przy wysokiej temperaturze czynnika płynącego prostopadle do powierzchni ożebrowanej, może to skutkować nieprawidłowym odbiorem ciepła przez czynnik roboczy płynący wewnątrz rurek wymiennika. Skutkuje to znacznym wzrostem naprężeń ściskających w rurach wymiennika, a w konsekwencji ich uszkodzeniem i awarią urządzenia. Generuje to znaczne koszty, związane z przerwami w pracy instalacji, kosztami naprawy, a nawet konieczności wymiany urządzenia.
EN
CFD (Computational Fluid Dynamics) computations are carried out in order to investigate the flow distribution and its influence on the heat transfer processes in the high-performance heat exchanger. The subject of this investigation is the classical model of the high-performance heat exchanger with elliptical tubes and rectangular fins. It is possible to find the flow domains where the heat transfer conditions are impaired due to the fully developed turbulent flow. Therefore, the considerable thermal loads occur that may cause the breakdown of the heat exchanger. The emphasis of this investigation is put on the zones and the locations where the tubes are not properly fed with liquid, that result in occurrence of cavitation.
EN
The finite element method (FEM) is one of the most frequently used numerical methods for finding the approximate discrete point solution of partial differential equations (PDE). In this method, linear or nonlinear systems of equations, comprised after numerical discretization, are solved to obtain the numerical solution of PDE. The conjugate gradient algorithms are efficient iterative solvers for the large sparse linear systems. In this paper the performance of different conjugate gradient algorithms: conjugate gradient algorithm (CG), biconjugate gradient algorithm (BICG), biconjugate gradient stabilized algorithm (BICGSTAB), conjugate gradient squared algorithm (CGS) and biconjugate gradient stabilized algorithm with l GMRES restarts (BICGSTAB(l)) is compared when solving the steady-state axisymmetric heat conduction problem. Different values of l parameter are studied. The engineering problem for which this comparison is made is the two-dimensional, axisymmetric heat conduction in a finned circular tube.
EN
The calculations of stresses acting on the wall of a boiler drum during the start-up process are presented in this paper. Based on the temperature measurements, which were carried out to determine the temperature distribution along the circumference of the outer wall of boiler drum, the temperature at the inner wall surface is determined using the inverse methods. The computations are carried out for the whole operation cycle of the power plant. Therefore, the pressure and temperatures are updated at consecutive time steps. These parameters allow determining the maximum values of circumferential, axial and Von Misses stresses during the operation cycle of steam boiler.
PL
W pracy przedstawiono obliczenia naprężeń w przekroju poprzecznym walczaka kotła OP-210 podczas jego rozruchu. Na podstawie pomiarów uzyskano wartości temperatury powierzchni zewnętrznej ścianki walczaka oraz poziom panującego w nim ciśnienia. Na podstawie znanych temperatur na powierzchni zewnętrznej ścianki walczaka rozwiązano zagadnienie odwrotne przewodzenia ciepła i wyznaczono pole temperatury w przekroju poprzecznym. Dla znanych obciążeń termicznych i ciśnieniem wyznaczono stan naprężenia w przekroju poprzecznym walczaka: maksymalne naprężenie zredukowane liczone według hipotezy HMH oraz maksymalne wartości składowych naprężenia: obwodowej, osiowej i promieniowej.
6
Content available remote Power efficiency management of photovoltaic energy source based on MPPT algorithm
71%
EN
In the paper energy supply system based on photovoltaic (PV) arrays was described. Also models of a single PV cell and a voltage boost converter were described. The boost converter was used for holding an appropriate work state of the PV arrays associated with its maximum power point level in various work conditions associated with irradiance level and the arrays temperature. Finally, comparison of two strategies of voltage level control in PV arrays system was put forward. These strategies were used to attain the maximum power point, and to define the work conditions, in which described control algorithms are the most effective.
PL
W artykule opisano system zasilania z wykorzystaniem baterii ogniw fotowoltaicznych. Przedstawiono model ogniwa fotowoltaicznego oraz przekształtnika podwyższającego napięcie. Przekształtnik ten zastosowano do utrzymywania właściwego stanu pracy związanego z maksymalną mocą osiąganą przez ogniwa w określonych warunkach pracy związanych z nasłonecznieniem i temperaturą ogniw. Przedstawiono porównanie dwu podstawowych strategii sterowania poziomem napięcia w układzie ogniw w celu uzyskania maksymalnego punktu pracy wraz z warunkami, w jakich opisane algorytmy sterowania są najskuteczniejsze.
EN
In this paper the simplified numerical analysis of water evaporation in vertical circular tubes is presented. Both temperature fields in the fluid and the solid domains are modeled. The temperature distribution inside the fluid domain is calculated using the Control Volume Method. For the solid domain, the Finite Element Method is used in order to determine the temperature field along the length of the tube. To conjugate the heat transfer between these two models, the heat transfer coefficient from the evaporating fluid is determined using the analytical Steiner-Taborek model. The pressure drop along the tube length is modeled using the Friedel correlation.