The principle of the new duaI wavelength B-correction spectrophotometric method recommended by its author, H.W. Gao in cases of high reagent bIank absorbance, ha been discussed. Doubts have been expressed about alfa-correction which occurs in the formulae and the method of its deteImination. The method has been used to examine spectrophotometric methods of determination of Mg(II) with eriochrome black T, Ca(II with murexide, AI(III) with eriochrome cyanine R, Cu(II) and Co(III) with pyridylazoresorcinolcinol. The purpose of the examination was to compare the results of detelrinations obtained by classical spectrophotometric method and B-correction method. It has beer confirmed that the application of B-correction alone increases the sensitivity and improves the precision and the accuracy of the methods in which reagent blank absorbency is high. It has been demonstrated that it is impossible to determine the correct alfa -correction value, and the application of the correction determined according to the 14ecommendations of' the authol4 of the method may lead to serious errors in the results.
PL
Omówiono zasadę nowej metody spektrofotometrii z B-korekcją przy dwu długościach fali, która jest polecana przez jej autora H. W. Gao w przypadku wysokiej absol4bancji ślepej próby. Zwrócono uwagę na wątpliwości jakie budzi występujący we wzorach współczynnik korekcyjny a i sposób jego wyznaczania. Metodę tę zastosowano do zbadania spektrofotometrycznych metod oznaczania Mg(II) z czernią eriochromową T, Ca(II) z mureksydem, AI(III) z eriochromocyjaniną R, Cu (II) i Co(III) z pirydyloazorezorcynolem. Badania miały na celu porównanie wyników oznaczeń uzyskiwanych klasyczną metodą spektrofotometryczną i metodą B-korekcji. Potwierdzono, że zastosowanie tylko B-kolekcji podwyższa czułość, poprawia precyzję i dokładność metod, w których absorbancja ślepej próby jest wysoka. Wykazano, że otrzymanie prawidłowej wartości współczynnika kol.ekcyjnego a nie .jest możliwe, a zastosowanie tego współ-czynnika wyznaczonego według wskazówek autora metody może powadzić do otrzymania wyników obarczonych bardzo dużymi błędami.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In the presence of cetyltrimethylammonium bromide (CTA) perchlorates form a sparingly soluble compound. The analysis has proved that it is cetyltrimethylammonium per-chlorate. In the present work gravimetric, nephelometric and turbidimetric methods of determination of perchlorates have been worked out. Measurements can be made in the pH range from 1.5 to 11.5. For 5 to 20 mg of perchlorate the gravimetric method and for 0.05 to 1.00 mg of perchlorate the nephelometric and turbidimetric methods can be used. The effect of foreign ions has been examined. Only large anions (e.g. MnO-(4), CrO4", Cr2O(2-), I-) interfere with the determination.
PL
Chlorany(VII) w obecności bromku cetylotrimetyloamoniowego (CTA) tworzą trudno rozpuszczalny osad. Analiza wykazała, że jest to chloran(VII) cetylotrimetyloamo-niowy. Opracowano wagową, nefelometryczną i turbidymetryczną metodę oznaczania chloranów(VII). Oznaczenia można wykonywać w zakresie pH od 1,5 do 11,5 dla chloranów(VII) w ilości 5-20 mg (metoda wagowa) lub 0,05-1,00 mg (metoda nefelometryczną i turbidymetryczną). Zbadano wpływ jonów obcych. W oznaczeniu przeszkadzają tylko duże aniony (np. MnO4, CrO(2)(4), Cr7(2), I(-).
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.