tom Vol. 23
433-442
EN
Investigations of partial discharges withis bars of generator coils have been made by means of acoustic emission method. Two ways of analysis of shapes of obrained AE amplitude distributtions are presented. The first cosists in definition and calculations of advanced AE desriptions, whichn can distinguish deformation process. The second way is based on Kohonen neuron network, used to distinguish and classify of images. The result of both mathod of analysis are compared with the measuremants of the apparent charge which have been curried out simultaneously to EA investigations.
|
|
tom R. 86, nr 11b
13-16
PL
W pracy przedstawiono wyniki analizy sygnałów emisji akustycznej zarejestrowanych w transformatorze olejowym. Dla zarejestrowanych sygnałów obliczono charakterystyki dające opisy podstawowy i zaawansowany. W ramach zaawansowanego opisu obliczono rozkłady amplitudowe, wartości deskryptorów ADP i ADC w wybranych pasmach częstotliwości i sporządzono mapy tych deskryptorów, na których znaleziono lokalne maksima. Analiza właściwości sygnałów emisji akustycznej ze zlokalizowanych obszarów doprowadziła do rozróżnienia sygnałów opisujących wyładowania niezupełne oraz wewnętrzne zakłócenie akustyczne. Sprawdzono zgodność wyników badań wyładowań niezupełnych uzyskanych niezależnie metodą emisji akustycznej i metodą elektryczną.
EN
Analysis results of acoustic emission signals in oil transformer are presented in the paper. Characteristics containing fundamental and advanced descriptions for recorded signals were calculated. Within advanced description amplitude distributions, descriptors named by acronyms ADP and ADC (named by authors) within chosen frequency bands and descriptors maps have been made. Local maxima within descriptors maps were identified and analysis of signals recorded in identified areas concluded distinction for signal produced by partial discharges or inner acoustic phenomena. Compatibility of the independent analyses of partial discharges investigation results obtained by means of electric and acoustic methods has been checked.
PL
W pracy przedstawiono autorski system analizy sygnałów zarejestrowanych w trakcie badań wyładowań niezupełnych (WNZ) w olejowych transformatorach energetycznych metodą emisji akustycznej (EA) obejmujący podstawową i zaawansowaną analizę zarejestrowanych danych. W ramach zaawansowanej analizy danych wyznaczane są mapy deskryptorów na ścianach bocznych transformatora i dokonywana jest lokalizacja źródeł WNZ autorską metodą stopnia zaawansowania sygnału. W pracy zaprezentowano wyniki takiej analizy dla sygnałów zarejestrowanych w trzech wybranych transformatorach. Na podstawie analizy zlokalizowano trzy źródła WNZ różnego rodzaju.
EN
The original system useful for analysis of signals recorded during investigations of partial discharges (PD) within power oil transformers by means of acoustic method (AE) is presented. This method includes the basic and advanced analysis of recorded data. In the frame of advanced analysis of data the maps of descriptors on lateral walls of a transformer are calculated; it is a base for location of sources of partial discharges by means of the original method consisted in determination of advance degree of a signal. Results of this analysis, for signals recorded in three chosen transformers are presented in the paper. Based on the analysis three different types of partial discharges sources have been located.
PL
W pracy przedstawiono wyniki badań sygnałów EA pochodzących od WNZ w wybranym pręcie cewki generatora. Podstawą analizy są rozkłady amplitudowe obliczone dla sygnałów EA zarejestrowanych w różnych punktach pomiarowych pręta przy różnych wartościach napięcia zasilania. Dla każdego rozkładu amplitudowego obliczono zdefiniowany przez autorów deskryptor o akronimie ADP przyporządkowujący sygnałowi jego stopień zaawansowania. Rodziny deskryptorów dla sygnałów EA zmierzonych w poszczególnych punktach pomiarowych przy różnych napięciach zasilania wykorzystano do rozróżnienia procesów deformacyjnych występujących w pręcie. Rodziny deskryptorów dla sygnałów EA zmierzonych w różnych punktach pomiarowych przy jednakowym napięciu zasilania wykorzystano do lokalizacji źródeł WNZ o maksymalnej aktywności.
EN
The investigation results of acoustic emission (AE) signals from partial discharges (PD) within a chosen generator coil bar are presented in the paper. The analysis is based on the amplitude distributions calculated for AE signals recorded at different measuring points for different values of the supply voltage. In order to assign the AE signal to its advance degree a descriptor named by an acronym ADP (defined by the authors) is calculated for each amplitude distribution. Descriptor families describing the AE signals measured at particular measuring points (for different supply voltages) are presented in relation to the apparent charge introduced by AE sources. These families concerning the AE signals, measured at different measuring points for the identical supply voltage, enable locating the AE sources of maximal activity.
5
Content available remote A new acoustic emission descriptor for modelled sources of partial discharges
51%
EN
Partial discharges (PD) generated by differently modelled PD sources have been studied by the acoustic emission (AE) method. The results obtained were compared with the measured apparent electric charge values. Acoustic images of the PD phenomena were created by recorded waveforms, phase diagrams, frequency characteristics and calculated amplitude distribution diagrams. Basing on the amplitude distributions, a new AE descriptor --- the ADP descriptor (Amplitude Distribution of Power of AE signal descriptor) was evaluated. The ADP descriptor distinguishes the physical processes connected with the PD. For the described measuring situations, the calculated values of the ADP descriptor show a good correlation of the ADP descriptor values with the value of the apparent electric charge.
|
2003
|
tom Vol. 24
237-248
EN
Basing on defined AE descriptors and on the Kohonen network an analysis of amplitude distribution of AE impulses registered at many points of tested object for different values of the supply voltage has been carried out. Using of modified loudness method of location the places with maximum activity of PD sources have been determined.
PL
Omówiono układ pomiarowy do badań wnz metodą akustyczną. Przedstawiono interpretację wyników i obliczeń oraz oceniono przydatność przetestowanych metod pomiaru.
EN
An acoustic emission measurement system for testing partial discharges has been described. Ways of interpreting measurement results and assess-ment of usefulness of the methods have been presented.
PL
Przedstawiono zaprojektowany i zbudowany przez autorów komputerowy system pomiarowy dedykowany do lokalizacji i opisu wyładowań niezupełnych w transformatorach energetycznych olejowych metodą emisji akustycznej. System pomiarowy sygnałów emisji akustycznej posiada 8 torów pomiarowych i zapewnia monitorowanie sygnałów i rejestrację danych w czasie rzeczywistym w paśmie 20-1000 kHz w warunkach laboratoryjnych i rzeczywistych. Przedstawiono autorski system analizy obejmujący podstawową i zaawansowaną analizę zarejestrowanych danych. W ramach zaawansowanej analizy danych obliczane są zdefiniowane przez autorów deskryptory, wyznaczane są mapy deskryptorów na ścianach bocznych transformatora i dokonywana jest lokalizacja źródeł wyładowań niezupełnych autorską metodą stopnia zaawansowania sygnału.
EN
Presented is designed and built by the authors a computerised measurement system dedicated to localization and description of partial discharges in power oil transformers with the use of acoustic emission method. The acoustic emission signals measurement system has 8 slotted lines and ensures monitoring of signals and real time data registration in 20-1000 kHz frequency band in both laboratory and real conditions. Presented is the author’s analysing system covering basic and advanced analyses of registered data. In the frames of the advanced data analysis the defined by the authors descriptors are calculated, descriptor maps are determined on transformer side walls as well as localization of partial discharges sources is made using the authors’ method of signal advancement level.