1
100%
|
|
tom Vol. 12, nr 1
59-74
EN
An innovatory on-line method of power system frequency estimation and voltage/current signals resampling is presented. The method is designed to increase the accuracy of power system equivalent harmonic impedance estimation using simple DAQ systems. Estimation of instantaneous frequency uses 5-th degree polynomial interpolation of filtered signal zero crossings time positions. Final resampling uses cubic splines interpolation for the calculation of output signal values. The details of resampling algorithm are described. The results of simulation tests demonstrating the typical behavior of a power system were shown as well as results of real voltage signal resampling. The method shows good capabilities of tracking varying harmonic phase angles in reference to the fundamental one while phase/frequency of fundamental harmonic varies too. The computational complexity allows to implement the method as a realtime version on DSP. Comparison of the amount of math operations used in this and another method [1] is shown too.
PL
W artykule przedstawiono innowacyjną metodę estymacji częstotliwości napięcia sieci energetycznej oraz sposób koherentnego repróbkowania sygnału napięcia sieci energetycznej. Potrzeba przepróbkowania sygnału wynika z faktu, iż częstotliwość napięcia sieci energetycznej nie jest stała lecz zmienia się w sposób ciągły. Proste systemy akwizycji danych najczęściej umożliwiają wybór stałej częstotliwości próbkowania i nie pozwalają synchronizować tejże z aktualną częstotliwością mierzonego sygnału. Fakt ten powoduje rozmycie prążków widma częstotliwościowego sygnału i utrudnia ocenę faz harmonicznych sygnału. Błędy estymacji widma sygnałów sieci energetycznej powodują powstanie znacznych błędów pomiaru zastępczej impedancji sieci energetycznej metodą bierną prezentowaną w [10]. Proponowana metoda wykorzystuje nowatorski sposób wyznaczania punktów czasowych, w których powinien zostać zrepróbkowany sygnał mierzony. Do wyznaczenia czasowych punktów repróbkowania wykorzystano interpolacje kolejnych wartości czasów przejść przez zero mierzonego sygnału. Wariant, pozwalający na repróbkowanie sygnału na bieżąco, wykorzystuje wielomian piątego stopnia do wyznaczenia stałej, całkowitej liczby punktów repróbkowania przypadających na jeden okres badanego sygnału. Warunki nałożone na wielomian interpolujący zapewniają ciągłość jego oraz jego pierwszej i drugiej pochodnej, nawet w warunkach pracy na bieżąco, gdy nie są znane chwile czasu przyszłych przejść sygnału przez zero. Dzięki ciągłości pochodnych wielomianu możliwa jest estymacja chwilowej częstotliwości podstawowej harmonicznej mierzonego sygnału zgodnie z zależnością (9). Otrzymany estymator jest gładki w porównaniu do innych estymatorów bazujących na metodach statystycznych [6, 7]. Repróbkowanie sygnału badanego w uprzednio wyznaczonych punktach czasowych wykorzystuje interpolację funkcjami sklejanymi trzeciego stopnia. Zaprezentowano wyniki testów symulacyjnych pokazujących typowe zachowanie systemu energetycznego oraz wyniki repróbkowania rzeczywistego sygnału napięcia sieci energetycznej dla kilku wybranych harmonicznych. Metoda ma dobre własności śledzenia zmieniających się kątów fazowych harmonicznych w odniesieniu do fazy podstawowej harmonicznej, nawet w sytuacji gdy faza lub częstotliwość podstawowej harmonicznej się zmienia. Złożoność obliczeniowa pozwala na implementację algorytmu na procesorze sygnałowym w celu zbudowania przyrządu pracującego w czasie rzeczywistym. Przedstawiono porównanie ilości operacji matematycznych potrzebnych do repróbkowania sygnału prezentowaną metodą oraz metodą wykorzystującą interpolację funkcją sinc.
|
|
tom Nr 3(103)
41--46
EN
The paper presents the control algorithm dedicated to a variable speed energy conversion system in a small hydropower plant. The energy conversion system consists of propeller water turbine, permanent magnet synchronous generator and power electronic converter. The main purpose of the algorithm, apart from the water level controlling, is to achieve the highest possible efficiency of the system. The changeable hydrological conditions, in the form of significant variations in a river’s flow and head throughout the year, requires to operate in a wide water flow and head range. Applied optimizing techniques guarantee maximal average efficiency independently of hydrological condition changes, by constant searching of the optimal operation parameters. The presented control method is implemented and tested in the energy conversion model, created in the Matlab/Simulink software. All characteristics and parameters were identified on the real small hydropower plant and on the special laboratory model.
3
Content available remote Control strategy for maximizing conversion efficiency of a small hydropower plant
100%
EN
An analysis of the energy conversion system which consists of a propeller water turbine, a permanent magnet synchronous generator and a power electronic converter is presented. The considered control strategy implements an optimizing technique that guarantees maximal average efficiency independently of hydrological condition changes through the constant search for optimal operation parameters. The water flow parameter, essential for objective function estimation, is eliminated by the dedicated control technique. The control method is implemented and tested in the model created in the Matlab/Simulink software. All characteristics and parameters were identified on a real small hydropower plant and on the special laboratory model.
PL
W artykule analizowany jest tor przetwarzania energii, który składa się z turbiny śmigłowej, generatora synchronicznego z magnesami trwałymi oraz przekształtnika energoelektronicznego. Przedstawiono strategię sterowania opartą na metodach optymalizacji, która przez ciągłe poszukiwanie optymalnych parametrów pracy gwarantuje maksymalną sprawność przetwarzania niezależnie od zmiennych warunków hydrologicznych. Przez wybraną technikę sterowania wyeliminowano konieczność znajomości parametru przepływu wody niezbędnego do oszacowania funkcji celu. Strategia sterowania została zaimplementowana i przetestowana w modelu opracowanym z zastosowaniem oprogramowania Matlab/Simulink. Wszystkie charakterystyki i parametry zostały zidentyfikowane w rzeczywistym obiekcie małej elektrowni wodnej i na stanowisku laboratoryjnym.
4
Content available remote System sterowania i monitoringu małej elektrowni wodnej
100%
PL
W artykule przedstawiono system sterowania i monitoringu dla małej elektrowni wodnej. Omówiono w nim zasady sterowania podstawowych parametrów w tego typu obiektach, ich realizację przez odpowiednie układy regulacji i przykładowe działanie. W drugiej części zaprezentowano sposób implementacji algorytmów sterowania przez zastosowanie określonych rozwiązań sprzętowych. Przedstawiono również metodykę i narzędzia implementacji programowej algorytmu sterowania. Zawarto wyniki rzeczywistego systemu sterowania i monitoringu MEW. W prezentowanym obiekcie jednostkami generacyjnymi są dwa hydrozespoły oparte na generatorze synchronicznym z magnesami trwałymi, pracujące ze zmienną prędkością obrotową o łącznej mocy 150 kW.
EN
This paper presents the control and monitoring system of a small hydropower plant (SHP). The control rules of the parameters in that type of objects, their practical realization by a dedicated control system and exemplary operation were described. In the second part the way of algorithm implementation using a modern hardware was presented. The control algorithm implementation from the software point of view was also shown. The paper contains the measurements from the real control and monitoring system of SHP. This SHP contains two permanent magnet (PM) generators of 75 kW electrical power each, which can work at a variable speed.
5
Content available remote Synchrophasor based Islanding Detection method
63%
EN
Unintentional islanding is one of the most disturbing issues of distributed generation. It has serious consequences for electricity and it poses a threat to life and health of the personnel. This paper makes a comparison between two islanding detection methods. The first method is the well known over/under voltage and over/under frequency passive method. The second method is a synchrophasor based method. The simulations proved that the two studied methods have a good performance for parallel RLC.
PL
Nieoczekiwane występowanie pracy wyspowej jest jednym z głównych problemów generacji rozproszonej. Praca wyspowa może mieć wpływ na jakość energii elektrycznej i stwarza poważne zagrożenie dla życia i zdrowia personelu. Ten artykuł porównuje dwie metody detekcji pracy wyspowej. Pierwsza metoda to dobrze znana metoda pasywna OUV/OUF (over under voltage and over under frequency). Druga metoda oparta jest na pomiarze synchrofazora. Symulacje wykazały, że obie metody sprawdzają się dla równoległego obciążenia RLC.
PL
Przedstawiono zasadę sterowania podziałem przepływu oraz mocy dla dwóch identycznych hydrozespołów.
EN
The paper presents principles of control of flow and power distribution for two identical hydroelectric turbine sets.
EN
A fast development of the computer based diagnostic and data acquisition systems as well as ever falling cost of various types of sensors and converters, together with the possibility of data transmission via various telecommunication systems, create an opportunity to build and to implement the diagnostic systems for the induction motors. This paper presents a concept of a Diagnostic Center for diagnosis of induction motors. We propose a distributed measuring system so called "telemeasuring" system which supporting diagnostic services located in a specialized Diagnostic Center. As for data transmission, the Internet and the LAN networks are used as inexpensive links, as it is more cost efficient to provide a remote the maintenance of the diagnostic service. The concept of the diagnostic system takes into consideration, on one hand the database of diagnostic patterns, on the other hand the database of archival measurements taken while using the machine. The functioning blocks of the diagnostic inference subsystem (the main element of Diagnostic Center) are presented. The realization of the Measuring Server WWW (the main element of distributed measuring system located in Diagnostic Center) is also described in detail in this article.
EN
In this paper, the realization of a distributed measuring system is presented. The so called Tele-Measuring System (TMS) is developed at our University. As for data transmission via TMS, the Internet and the Ethernet networks are used as inexpensive reliable links. The measuring process requires installation of suitable sensors or actuators. In our case, we used the Hall effect converters (LEM), which convert the measured values of currents to voltage. The implementation of the LEM sensors in the Ethernet network requires an installation of a new smart device (data collector) that has an A/D converter, microcontroller with data flash and a LAN controller with embedded WEB server in one small package. The data collectors equipped in Ethernet 10Base-T adapters with RJ-45 connectors allow to build local measuring networks in star topology up to 100m distance between measuring object and nearest hub or switch. This board makes many measuring applications imaginable. Think of a diagnostic that can be easily controlled using either special front-end software and comfortable Internet browser from anywhere around the World. The detailed TMS elements design is described in this article.
PL
Dokładność nieinwazyjnego wyznaczania parametrów modelu Thevenina części systemu elektroenergetycznego, widzianej z punktu pomiaru w stronę zasilania, jest silnie uzależniona od poziomu pobudzenia, którym w tym wypadku są zmiany obciążenia występujące podczas normalnej pracy systemu. W sytuacji, gdy parametry strony badanej również ulegają zmianom podczas eksperymentu, wyniki mogą być błędne. W artykule wskazano jak, na podstawie znajomości specyfiki pracy systemu energetycznego, wybrać lokalizację nieinwazyjnego pomiaru, która ograniczy wpływ zmian parametrów strony badanej na wyniki pomiaru. Jako potwierdzenie stawianych tez przedstawione są przykładowe wyniki pomiarów na obiektach rzeczywistych.
EN
The accuracy of noninvasive determination of part of power system modeled as a Thevenin circuit, seen from the measurement location toward the supply, strongly depends on excitation level, which, in this case, are natural load changes. If a source (analyzed) side parameters change during an experiment, results can be wrong. The article points out how, based on a character of power grid operation, to choose a non-invasive measurement location in order to limit influence of parameter changes on obtained results. Real-world measurement results are presented as a confirmation of presented theses.
EN
This paper presents an analytical model of a three-phase axial flux coreless generator excited by permanent magnets, with special focus on determining the model parameters. An important aspect of this model is the derivation of a coefficient that corrects the flux on the inside and outside edges of the magnets. The obtained parameters are verified by performing field analyses and measurements. A comparison of the results show satisfactory convergence, which confirms the accuracy of the proposed analytical model.
PL
W pracy poruszono problematyką bezpieczeństwa ruchu drogowego związaną ze stosowaniem drogowych barier ochronnych. Opisano zadania, jakie powinien spełniać system ochronny. Celem pracy było dokonanie oceny skuteczności betonowych systemów ochronnych instalowanych na łukach drogi. Zrealizowano je , wykorzystując betonową barierę wyposażoną w prototypowy sprzęg łączący poszczególne segmenty bariery. Do badań modelowych przyjęto samochód o masie 900 kg, umożliwiający zrealizowanie testu TB11 wg normy EN 1317-2. Do modelowania wykorzystano oprogramowanie LS-DYNA, wykorzystujące metodę elementów skończonych. W pracy zamieszczono wyniki badań numerycznych, trajektorię ruchu samochodu oraz przemieszczenia barier. Zamieszczono również przykładowe przebiegi przyspieszeń wybranych elementów pojazdu oraz obliczony na ich podstawie wskaźnik ASI służący do oceny stopnia zagrożenia ludzi znajdujących się w pojeździe. Uzyskane rezultaty świadczą o istotnym wpływie promienia łuku drogi, wyposażonego w ochronną barierę betonową, na przebieg i skutki zderzenia.
EN
The work raised a problem of the road safety issue related to the use of road safety barriers. The tasks that have to be fulfilled by the protective system were described. The aim of work was to assess the effectiveness of concrete protective systems that are installed on the road curves. The model tests have been performed with prototype concrete barrier and a 900 kg passenger car which allows to perform TB11 test according to EN 1317-2 standard. The modeling have been performed with LS-DYNA software, which uses the finite element method. The numerical test results, vehicle motion trajectory and barrier displacement were presented in the paper. Examples of speed and acceleration courses of selected vehicle elements and the ASI index calculated on that basis which was used to assess the danger level for the vehicle passengers were also included. Obtained results indicate that a road curve radius values has essential influence on the course and effect of accident.