In a number of EU countries medium voltage networks operate in the compensated neutral mode. In that case an arc suppression coil is commonly shunted with a resistor. The most common type of damage to such networks is a single phase-to-ground fault. The paper presents the method for two stage identification of a line where the fault has occured. The first stage is based on the analysis of high frequency components arising under transients. At the first stage a continuous wavelet transform is used to find frequencies. The second stage involves an analysis of the steady-state mode of a single phase-to-ground fault. Based on the energy spectrum of higher harmonics a damaged line is detected. To determine the energy spectrum at the second stage of the work a wavelet packet transform is applied. Wavelet transform has a number of advantages compared with short-time Fourier transform (STFT), particularly when analyzing non-stationary modes. The proposed method can be implemented to organize digital protection against ground faults.
PL
Sieci średniego napięcia w wielu krajach UE działają w skompensowanym trybie neutralnym. W takim przypadku cewka gasząca łuk jest zwykle bocznikowana przez rezystor. Najczęstszym rodzajem uszkodzeń w takich sieciach jest zwarcie jednofazowe do ziemi. W artykule przedstawiono technikę dwuetapowej identyfikacji linii, na której nastąpiło uszkodzenie. Pierwszy etap opiera się na analizie składowych wysokiej częstotliwości powstających pod wpływem stanów nieustalonych. W pierwszym etapie do znalezienia częstotliwości używana jest ciągła transformata falkowa. Drugi etap obejmuje analizę stanu ustalonego pojedynczego zwarcia międzyfazowego. Na podstawie widma energii wyższych harmonicznych wykrywana jest uszkodzona linia. Do wyznaczenia widma energii w drugim etapie pracy stosuje się transformację pakietu falkowego. Transformacja falkowa ma wiele zalet w porównaniu z krótkotrwałą transformatą Fouriera, szczególnie w przypadku analizy modów niestacjonarnych. Zaproponowaną metodę można zaimplementować do organizacji cyfrowej ochrony przed zwarciami doziemnymi.
EN
One of the key indicators of the energy efficiency of electrical power systems should include the level of electric power losses. In a market economy, the significance of losses increases, since the cost of losses is an essential component of the tariff. One of the effective measures to reduce power network losses is reactive power compensation. However, the cost of compensating devices used for this purpose disagree with the task of reducing electric energy losses. The paper describes the effect of changing the capacity of static capacitor banks on the value of losses in the network with variation in the number of sections and the type of annual reactive load curves. The effect of the number of capacitor bank sections on the maximum reduction of annual reactive power losses in the network is analyzed. For the linearized load graphs, the relations for the values of natural losses in the capacitor banks are obtained, as well as expressions applicable to estimate the reduction of losses in the network. The conclusion is drawn that full reactive power compensation is impractical in most cases. The dependence of loss reduction on the power of capacitor banks reaches the maximum at the point where the battery power is less than the load power. It is proved that significant reduction of the loss in reactive power transmission in the electrical network requires no more than 3-4 sections (the reduction is close to 100 percent), and a 90 percent reduction in a wide range of load curves can be achieved with two sections.
PL
Do najważniejszych wskaźników efektywności energetycznej systemów elektroenergetycznych należy zaliczyć poziom strat energii elektrycznej. W warunkach gospodarki rynkowej wzrasta znaczenie strat, ponieważ koszt strat jest istotnym składnikiem taryfy na energię elektryczną. Jednym ze skutecznych działań mających na celu zmniejszenie strat w sieciach elektrycznych jest kompensacja mocy biernej. Jednak koszt wykorzystywanych do tego celu urządzeń kompensacyjnych stoi w pewnych sprzeczności z zadaniem zmniejszenia strat energii elektrycznej. W pracy przedstawiono wyniki wpływu zmiany mocy akumulatorów kondensatorów statycznych na wielkość strat w sieci przy zmienności liczby sekcji i rodzaju rocznych Wykresów obciążenia biernego. Przeprowadzono analizę wpływu liczby sekcji akumulatorów kondensatorów na maksymalne zmniejszenie rocznych strat w sieci na transmisję mocy biernej. Dla zlinearyzowanych Wykresów obciążenia uzyskuje się relacje opisujące wartości strat własnych w akumulatorach kondensatorów, a także wyrażenia mające zastosowanie do oceny redukcji strat w sieci. Stwierdzono, że pełna kompensacja mocy biernej jest w większości przypadków niepraktyczna. Wynik opiera się na tym, że maksymalna zależność redukcji strat od mocy akumulatorów kondensatorów jest osiągana w punkcie, w którym moc akumulatora jest mniejsza niż moc obciążenia. Uzasadnione jest twierdzenie, że nie więcej niż 3-4 sekcje są wymagane do znacznego zmniejszenia strat mocy biernej w sieci elektrycznej (zmniejszenie zbliża się do 100 procent), a zmniejszenie o 90 procent w szerokim zakresie Wykresów obciążenia można osiągnąć, gdy istnieją dwie sekcje.