The 12th International Conference on Noise Control - Noise Control'01 - was held in Kielce on 23-26 September, 2001. The conference was organized by the Acoustic Committee of the Polish Academy of Sciences, the Polish Acoustic Society, the Central Institute for Labour Protection, the Department of Mechanics and Vibroacoustics of the University of Mining and Metallurgy, and the Building Research Institute.
W artykule omówiono obowiązujące w Polsce przepisy prawne oraz algorytmy postępowania przy prowadzeniu oceny ryzyka zawo- dowego związanego z narażeniem na hałas i drgania mechaniczne. Przedstawiono propozycje oceny ryzyka zawodowego dla tych zagrożeń za pomocą wskaźników cząstkowych i całkowitych. W zakresie hałasu propozycje wskaźników wyznaczono na podstawie wyników badań w halach przemysłowych, natomiast w przypadku drgań - na podstawie obliczeń teoretycznych i badań laboratoryjnych.
EN
The paper discusses current Polish regulations and algorithms for occupational risk assessment caused by exposure to noise and vibrations. A proposal for occupational risk assessment of those hazards with the use of partial and total indices is presented. For noise, the proposed indices were developed on the basis of the results of tests carried out in the industry, whereas for yibration they result from theoretical calculations and laboratory tests.
The paper presents vibroacoustic tests of power transformers with regard to active reduction of their noise. Basic sources of vibroacoustic energy are determined and a system of active reduction of noise (ANC) emitted by power transformers, developed by CIOP-PIB, is presented. Moreover, the results of preliminary tests of the system in real conditions are presented.
PL
W artykule przedstawiono opracowany w CIOP-PIB system aktywnej redukcji hałasu emitowanego przez transformatory energetyczne. Omówiono wyniki analizy przepływu energii wibroakustycznej w transformatorach oraz struktury zrealizowanych wariantów systemu ze szczególnym uwzględnieniem układu kontrolera i algorytmu sterującego. Przedstawiono również wyniki badań laboratoryjnych systemu z wykorzystaniem modelu transformatora oraz badań w warunkach rzeczywistych dla dwóch typów transformatorów energetycznych.
Transformatory energetyczne są źródłem hałasów niskoczęstotliwościowych, emitowanych głównie przez obudowy. Redukcję tego hałasu uzyskać można metodami aktywnymi. W artykule pokazano przydatność rozwiązań falkowych do aproksymacji pierwotnych cech akustycznych sygnałów emitowanych przez obudowy w czasie pracy transformatorów istotnych w procesie budowy układów sterowania redukcją hałasu.
EN
Power transformers are the source of Iow frequency noise emitted mainly by transformer's cases. This noise can be reduced using active methods. The article presents the usability of wavelet solutions for the approximation of primary acoustic features of signals emitted by transformer cases, in designing of active noise reduction systems control units.
This article presents selected results of analyses and simulations carried out as part of research performed at the Central Institute of Labor Protection – the National Research Institute (CIOP-PIB) in connection with the development of a system for active reduction of noise emitted by high power electricity transformers. This analysis covers the transformer as a source of noise as well as a mathematical description of the phenomenon of radiation of vibroacoustic energy through a transformer enclosure modeled as a vibrating rectangular plate. Also described is an acoustic model of the transformer in the form of an array of loudspeakers.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper deals with some vibroacoustic processes occuring within the power transformer casing. The acoustic system is modeled by a simply supported rectangular plate embedded within the planar rigid baffle. The radiation directivity pattern of the system is specially focused on since it will be useful for the determination of the eigenfunctions of the system; the latters are necessary for some further analysis of the total sound power radiated by the system and the resultant distribution of the sound pressure radiated as well as for some further investigations on the noise control of the system.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The equation of motion of a flat simply supported rectangular plate has been solved. The plate has been excited by a surface force. The influence of the acoustic pressure radiated by the plate on its vibrations has been included. The corresponding sound pressure distributions have been presented as their backward Fourier transforms. The acoustic active and reactive sound power has been computed including the influence of the sound pressure radiated by the piston. The acoustic mutual sound power of both sources has also been presented.
W artykule przedstawiono problematykę rozwoju zrównoważonego w odniesieniu do analizy wibroakustycznej środowiska pracy. Podano zasady tworzenia wskaźników rozwoju zrównoważonego oraz wskaźników wibroakustycznych środowiska pracy: globalnego WG i cząstkowych Wi. Zasady te zilustrowano przykładową analizą klimatu akustycznego przeprowadzoną dla hali przemysłowej.
EN
This article presents problems of sustainable development in relation to a vibroacoustic analysis of the work environment. It discusses rules of creating indicators of sustainable development as well as vibracoustic indicators of the work environment: global WG and partial Wi. A sample analysis of the acoustic climate performed in an industrial yard illustrates those rules.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.