Results of measurement of direct voltage distribution along a string of glass cap-and-pin insulators was shown in the paper. As a research objects 3 different types of insulators were chosen: LK 280/165 (used in AC power lines), U40B produced by LVIV Insulator Company (used also in AC and DC power lines), F16P/C170DC produced by SEDIVER Company (used only in DC power lines). The comparison of measurement of voltage distribution using compensation method and results of measurements acquired with symmetric and asymmetric sphere gap methods was done. The comparison of measurement results of voltage distribution on a string of insulators with calculated voltage distribution based on the resistance of each particular insulator was also done.
PL
Tematem artykułu są wyładowania niezupełne na powierzchni preszpanu zanurzonego w oleju mineralnym lub estrze syntetycznym. Są to jedne z najbardziej niebezpiecznych wyładowań. Badano wyładowania typu powierzchniowego oraz ślizgowego. Stwierdzono, że wyładowania niezupełne na powierzchni preszpanu zanurzonego w estrze syntetycznym mają trochę większą intensywność niż zanurzonego w oleju mineralnym.
EN
The theme of the article are partial discharges on surface of pressboard immersed in mineral oil or synthetic ester. These are some of the most dangerous discharges. Partial discharges of surface type and sliding type were tested. It has been found that the partial discharges on the surface of the pressboard immersed in a synthetic ester have a slightly higher intensity than immersed in mineral oil.
PL
W artykule przedstawiono rys historyczny rozwoju inżynierii wysokich napięć w Politechnice Poznańskiej. Przedstawiono najważniejsze tematy badawcze. Wymieniono wybrane zrealizowane i aktualnie realizowane projekty, wśród nich: projekty międzynarodowe, projekty własne badawcze finansowane przez KBN i MNiSzW, projekt rozwojowy oraz kontrakty i umowy z energetyka zawodową. Opisano specjalistyczne laboratorium diagnostyczne transformatorów energetycznych wysokiego napięcia, przedstawiając zestaw aparatury, źródło finansowania i koszty.
EN
The paper describes the historical outline of the development of high voltage engineering at Poznan University of Technology. The most important research topics were presented. Chosen realised and currently carried-on project were mentioned, amongst them: international projects, projects financed by State Committee for Scientific Research as well as Ministry of Science and Higher Education, developmental project and also contracts and agreements with electric power engineering sector. There is also a description of diagnostics laboratory for high voltage power transformers investigation with presentation of the equipment, financing sources and costs.
EN
The paper presents measurement results of breakdown bridge resistance, which can form in oil (it was under DC voltage). The measurements were done using two sphere electrodes for different volumes of oil. Electric field intensity distribution in the analyzed area was computer-simulated. The computer simulation can help determine the minimal value of electric field intensity which can lead to migration of contaminants into the electrode gap.
PL
W artykule przedstawiono możliwości wykorzystania spektroskopii dielektrycznej w badaniach właściwości materiałów. Zaprezentowano wyniki badań odpowiedzi dielektrycznej izolacji papierowo-o I ej owej w aspekcie oceny jej zawilgocenia i zestarzenia. Porównano parametry dielektryczne próbek preszpanu i papieru impregnowanego o różnym stopniu zawilgocenia i zestarzenia w różnych temperaturach.
EN
The paper presents applications of dielectric spectroscopy in investigations of materials properties. The results of dielectric spectroscopy investigations of oil-paper insulation was presented in aspect of moisture content and aging evaluation. Dielectric parameters of impregnated paper and pressboard of different moisture content and aging state was compared at various temperatures.
EN
In this article the results of water content measurements in test transformers paper insulation are presented. This choice of research objects was achieved because the equilibrium state of water content in paper and oil was expected. That is a consequence of equal and constant transformer temperature. The state of equilibrium is the one of main condition to diagnose correctly the insulation system. The polarization methods (RVM, FDS) and chemical methods (Oommen's and S.D. Myers' curves) were used. Water content in oil was determine in three independent laboratories. The comparison of moisture content in paper insulation between four methods was done.
PL
Przedstawiono wyniki badań zawilgocenia izolacji ponad 70 transformatorów mocy pracujących w polskim systemie energetycznym. Zebrane wyniki dotyczą jednostek badanych w latach 2004 - 2008. W ocenie zawilgocenia wykorzystano spektroskopię dielektryczną w dziedzinie częstotliwości (FDS). Wspomagano się również danymi pochodzącymi z badań metodami fizykochemicznymi. Wyciągnięto alarmujące wnioski dotyczące zawilgocenia izolacji.
EN
The paper presents the investigation results of insulation moistening of over 70 transformers operating in the Polish power grid. The results were obtained from examining the transformers in the years 2004-2008. In the assessment of moisture content the frequency domain spectroscopy was used. Additionally, the physicochemical methods were applied. The authors came to the alarming conclusion concerning the moistening of transformer insulation.
PL
W artykule przedstawiono zebrane wyniki badań transformatorów przeprowadzonych w Polsce, Niemczech i Szwecji w ramach międzynarodowego projektu badawczego REDIATOOL. W znakomitej większości były to transformatory zainstalowane w sieciach przesyłowych, mniejszą część stanowiły transformatory blokowe, rozdzielcze i potrzeb własnych. Spośród wszystkich badanych na przestrzeni 3 lat transformatorów, osiem jednostek badano powtórnie po upływie co najmniej roku. Przedstawione w pracy zestawienia statystyczne dowodzą, że dla jednostek podobnych typów, eksploatowanych według ustalonych zasad, można określić wiek transformatora, po przekroczeniu którego, procesy starzeniowe w izolacji zachodzą znacznie szybciej niż dla jednostek nowych.
EN
The paper describes the set of investigation results carried out in Poland, German and Sweden collected within a framework of international research project -REDIATOOL. The investigations were done on transmission transformers, as well as generator step-up (GSU) transformers, distribution and internal load transformers. The eight units have been analysed twice in period of 3 years of project execution. Presented statistical overview proves that for the similar types of transformers which operate in similar condition it is possible to estimate the transformer age after which the aging processes occur faster then for new units.