Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A complexometric method for the determination of mercury in the presence of other metal ions based on the selective masking ability of thioglycollic acid towards mercury is described. Mercury(II) present in a given sample solution is first complexed with a known excess of EDTA and the surplus EDTA is titrated against lead nitrate solution at pH 5.0-6.0 (hexamine) using xylenol orange as indicator. A known excess of thioglycollic acid solution (1%) is then added, the mixture is shaken well, and the EDTA released from the Hg-EDTA complex is titrated against standard lead nitrate solution. Reproducible and accurate results are obtained for 1.6-80 mg of mercury with relative error 0.7% and standard deviation <0.1 mg. The interference of various ions was studied. This method was applied to the determination of mercury(II) in its alloy compositions.
PL
Opisano kompleksometryczną metodę oznaczania rtęci(II) w obecności innych jonów, w której wykorzystano selektywne wiązanie jonów rtęci za pomocą kwasu tioglikolo-wego. Rtęć w próbce jest początkowo kompleksowana znanym nadmiarem EDTA i nadmiar EDTA jest odmiareczkowywany za pomocą roztworu azotanu ołowiu przy pH 5.0—6.0 w buforze heksaminowym w obecności oranżu kśylenolowego jako wskaźnika. Następnie dodaje się 1% roztwór kwasu tioglikolowego, mieszaninę wstrząsa, a nadmiar uwolnionego EDTA odmiareczkowuje roztworem azotanu ołowiu. W zakresie od l .6 do 80 mg rtęci(II) uzyskuje się wyniki z błędem względnym 0,7% i odchyleniem standardowym mniejszym od O, l mg. Badano wpływ szeregu jonów, a metodę zastoso-wano do oznaczania rtęci w stopach.
EN
A complexo-titrimetric method for the determination of copper(II) in the presence of foreign metal ions and the masking agent - DL-penicillamine selective towards copper(II) has been described. All of the ions present in the sample solution are initially complexed by EDTA and the excess of EDTA is titrated with zinc sulfate solution at pH 5.0-6.0 (hexa-mine), using xylenol orange as the indicator. The known amount of DL-penicillamine solution (1%) is then added, the mixture is shaken thoroughly and EDTA released from Cu-EDTA complex is titrated with standard zinc sulfate solution. The interference from various ions was studied. The method was applied to the determination of copper in its ores, alloys and complexes. Reproducible and accurate results were obtained for the copper amount ranging from 1.3 to 44.5 mg; the standard deviation was lower than 0.05.
PL
Opisano kompleksacyjno-miareczkową metodę oznaczania miedzi(II) w obecności innych jonów metali wykorzystując zdolność selektywnego maskowania miedzi(II) przez DL-penicylaminę. Miedź i inne jony w roztworze kompleksuje się EDTA, którego nadmiar miareczkuje się roztworem siarczanu cynku przy pH 5,0-6,0, stosując jako wskaźnik oranż ksylenolowy. Następnie dodaje się znany nadmiar roztworu DL-penicylaminy (1%) i dokładnie miesza. EDTA uwolniony z kompleksu CuEDTA miareczkuje się roztworem siarczanu cynku. Zbadano wpływ różnych jonów. Metodę zastosowano do oznaczania miedzi w jej rudach, stopach oraz kompleksach. Powtarzalne i dokładne wyniki oznaczania miedzi uzyskano przy zawartości miedzi w granicach od l ,3 do 44,5 mg; odchylenie standardowe wynosiło < 0,05.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.