Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 11

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
|
|
tom z. 88
173-178
EN
In the paper the results of research work on shaping properties of gypsum-based materials, mainly for external walls, are presented. The test results demonstrate that synthetic gypsum, modified by admixtures and additives, is suitable for obtaining material which fulfils demands for homogenous external walls similar to cellular concerts as e.g. YTONG.
2
Content available remote Preliminary research into the digestion of post-coagulation sludge
100%
EN
An increasingly higher number of water treatment plants are currently searching for a technology which would make it possible to dispose post-coagulation sludge from water treatment processes. Due to the fact that sludge contains a substantial amount of organic compounds, some tests were conducted to see how such sludge can be stabilised in anaerobic conditions. Sludge supplied by two water treatment plants was tested. Sludge 1 was a mixture of sludge from the treatment of filter backwash water and backwash water separated from water after coagulation. Sludge 2 was the product of the treatment of backwash water from carbon and contact filters as well as wastewater produced when primary settling tanks are cleaned. Prior to digestion, post-coagulation sludge was inoculated with the sewage sludge collected from the anaerobic digester of a municipal wastewater treatment plant. To determine the effectiveness of the tests, the sewage sludge used as an inoculate was also digested. The digestion process was conducted for 35 days at a temperature of 37 °C. Compared to sewage sludge, a small amount of the sludge-digestion gas produced by the post-coagulation sludge was observed during the process. For the sewage sludge, the sludge-digestion gas evolution rate per volatile solids (VS) input was 0.19 m3/kg VS, for post-coagulation sludge 1-0.09 m3/kg VS and for post-coagulation sludge 2-0.05 m3/kg VS. The sludge mineralization rate expressed as a percentage loss of dry volatile solids was the highest for the sewage sludge alone and it was 19%, whereas for the post-coagulation sludge it was 11.8% (sludge 1) and 5.8% (sludge 2). The digestion process substantially enhanced the filtration properties of the tested sludge. The post-coagulation sludge produced small volumes of sludge digestion gas, thus it can be stated that the digestion of this sludge alone would not be technically nor economically profitable. Therefore, research into the digestion of post-coagulation sludge with a considerably higher share of sewage sludge should be done to identify the potential for their costabilization. Such a solution would provide a potential opportunity for resolving the problem of post-coagulation sludge through its disposal in wastewater treatment plants.
3
Content available remote Charakterystyka osadów pokoagulacyjnych
100%
PL
Prawo z zakresu ochrony środowiska wymaga od przedsiębiorstw wodociągowych rozwiązania gospodarki osadowej na większości stacji uzdatniania wody. Ze względu na nierozpoznany charakter osadów, zmienny skład chemiczny i zmienne właściwości fizyczne łych osadów w zależności odpory roku, dotychczas nie opracowano efektywnej technologii ich unieszkodliwiania i przeróbki. W pracy zaprezentowano wyniki badań mających na celu określenie właściwości fizyko-chemicznych osadów powstających na jednej ze stacji uzdatniania wody województwa śląskiego.
EN
Environmental Protection Law reąuires the sludge management solutions in most of water treatment plants. On account of unrecognized sludge condition, variable chemical composition and changeable physical properties of sludge depending on season, the effective technology of sludge utilization and treatment has not been yet. The research shows us the efrects of investigations of physical and chemical properties of sludge in one of the water treatment plant in Silesia, Poland.
4
Content available remote Aerobic digestion of post-coagulation sludge
80%
EN
An increasingly higher number of water treatment plants (WTP) are currently searching for a technology that would make it possible to disposal post-coagulation sludge produced by water treatment processes. Due to their substantial content of organic compounds, some tests were conducted to see how such sludge can be stabilized in aerobic conditions. Post-coagulation sludge supplied by water treatment plant was tested used. Post-coagulation sludge result from carbon and backwash water of contact filter and the wastewater produced when primary settling tanks are cleaned. The efficacy of the process depended on the properties of sludge and the duration of the process. Post-coagulation sludge by WTP showed a relatively constant percentage of organic matter (39.5% Total Solids – TS). In aerobic digestion the organic matter reduction rate amounted, on average, to 4-22%, depending on the duration of the process. Aerobic digestion conducted in less than 12 days allowed for a small reduction in organic matter (4.0-13.2%). But when the process was extended more than 23 days it ensured the reduction in content of organic compounds by about 18% and allowed to obtain sludge characterized by earthy scent and not showing a tendency to putrefy.
PL
Obecnie coraz więcej przedsiębiorstw wodociągowych poszukuje technologii pozwalającej na unieszkodliwianie osadów pokoagulacyjnych powstających w procesach oczyszczania wody. Z uwagi na znaczną zawartość w nich związków organicznych przeprowadzono badania ich stabilizacji w warunkach tlenowych. Do badań wykorzystano osady pokoagulacyjne z zakładu produkcji wody (ZPW), powstające w wyniku oczyszczania popłuczyn z filtrów węglowych, filtrów kontaktowych oraz ścieków z czyszczenia osadników. Efektywność stabilizacji zależała od właściwości osadów oraz czasu trwania procesu. Osady pokagulacyjne z ZPW charakteryzowały się w miarę stałym udziałem masy organicznej wynoszącym około 39.5% sm. Podczas stabilizacji tlenowej uzyskiwano redukcję masy organicznej od 4% do 22% w zależności od czasu trwania procesu. Stabilizacja prowadzona w czasie krótszym od 12 dni pozwalała na niewielką redukcję masy organicznej (4.0-13.2%). Natomiast wydłużenie czasu procesu powyżej 23 dni zapewniało obniżenie zawartości związków organicznych o około 18% oraz pozwalało na uzyskanie osadów charakteryzujących się ziemistym zapachem i niewykazujących tendencji do zagniwania.
PL
W komunalnej oczyszczalni ścieków w technologii przeróbki osadów zazwyczaj stosowany jest proces odwadniania mechanicznego. W procesie tym oprócz odwodnionego osadu powstają tzw. odcieki. Odcieki charakteryzują się dużym ładunkiem zanieczyszczeń, w tym dużym stężeniem fosforu. W przypadku zawracania do ciągu oczyszczania ścieków stanowią one dodatkowe obciążenie ładunkiem zanieczyszczeń. Z tego względu powinny być wcześniej podczyszczane w bocznym ciągu oczyszczania. Z kolei wody popłuczne pochodzące ze stacji uzdatniania wód podziemnych zawierają duże stężenie jonów żelaza. Wymieszanie wód popłucznych z odciekami może okazać się korzystnym rozwiązaniem. W związku z tym podjęto badania wykorzystania wód popłucznych do oczyszczania odcieków. Wprowadzone sole żelaza(III) do odcieków ulegają hydrolizie, tworząc hydroksykompleksy. W takiej postaci hydrokompleksy związków żelaza w odciekach mogą prowadzić do sorpcji zanieczyszczeń, powstawania kompleksów soli żelaza oraz współstrącania i strącania osadów. Celem badań było określenie wpływu wód popłucznych na jakość odcieków pochodzących z odwadniania osadów ściekowych z komunalnej oczyszczalni ścieków. Proces koagulacji odcieków z wodami popłucznymi prowadzono w temperaturze 6 i 20°C. Odcieki z wodami popłucznymi mieszano w taki sposób, aby uzyskać stosunek Fe/P, wynoszący 0,5; 1,0; 1,5; 2,0; 2,5; 3,0. Przeprowadzone badania wykazały, że po procesie w odciekach uzyskano obniżenie zarówno stężenia fosforu, jak i zawartości ChZT, odpowiednio do poziomu 4,5-20,7 mg/dm3 w temperaturze 6°C i 4,5-8,4 mg/dm3 w temperaturze 20°C oraz 79-180 mg/dm3 w temperaturze 6°C i 72-140 mg/dm3 w temperaturze 20°C.
EN
Mechanical dewatering process is most typically method of sludge treatment used on municipal sewage treatment plant. In this process leachate are generated besides the dewatered sludge. Leachate has a high pollutant load, including a high concentration of phosphorus. In the case of discharging them to the main line of wastewater treatment, they are additional load of organic and phosphorus compounds. Therefore, they should be previously pre-treating in the side-treatment system. The backwash water from groundwater treatment plants contain a high concentration of iron ions. Mixing backwash water and leachate may be preferred solution. Therefore, study was carried using backwash water to leachate treatment. Salts of iron(III) submitted to the effluents are hydrolyzed and are formed hydroxy complexes. In this form iron can cause sorption of pollutants, formation of complexes of iron salts and co-precipitation or precipitation of sludge. The aim of this study was to determine the effect of backwash water on quality of leachate from the dewatering process of sludge from municipal sewage treatment plant. The coagulation process of backwash water with leachate was carried out in 6 and 20°C. The leachate and backwash water were mixed in such proportion to obtain the ratios of Fe/P equaled to 0.5; 1.0; 1.5; 20; 2.5; 30. The study showed that the following process allowed to reduce both phosphorus and COD concentration in the leachate. Concentrations of phosphorus compounds after process were in range of 4.5-20.7 and 4.5-8.4 mg/dm3 respectively at 6 and at 20°C. In the case of COD, its value in leachate after coagulation was in range of 79-180 and 72-140 mg/dm3 respectively at 6 and at 20°C.
6
80%
PL
Przeprowadzono badania podczyszczania odcieków pochodzących z „młodego” składowiska odpadów komunalnych za pomocą odpędzania amoniaku przy użyciu CaO. Głównym celem podczyszczania było obniżenie stężenia związków organicznych (ChZT) oraz azotu amonowego zawartego w odciekach. Określono wpływ czasu reakcji oraz dawki CaO na wartość parametru ChZT oraz stężenie azotu amonowego w odciekach. Badania wykazały, że w przypadku usuwania związków organicznych nie odnotowano znacznego wpływu czasu reakcji, gdyż zwiększanie czasu flokulacji z 20 do 60 minut nie poprawiało efektywności oczyszczania. Natomiast na stopień obniżenia wartości ChZT miała wartość dawki CaO. Zwiększenie dawki z wartości 5 do 25 g/dm3 (L) umożliwiło zwiększenie stopnia obniżenia ChZT z 22,2 aż do 59,3%. W przypadku natomiast usuwania azotu amonowego widoczny był wpływ czasu odpędzania. Wydłużenie czasu reakcji z 1 godziny do 24 godzin (dawka CaO równa 17,5 g/dm3 (L)) umożliwiło zwiększenie efektywności od 14,3 do 79,4% usunięcia N-NH4.
EN
Pre-treatment of leachate from “young” municipal landfill by stripping ammonia with CaO was conducted. The main objective of experiments was to reduce the concentration of organic compounds and nitrogen in the leachate. The influence of CaO dosage and reaction time on COD and ammonium nitrogen removal was checked. Studies have shown that at 20 minutes of reaction (25 g/dm3 dose of CaO) a considerable high removal of organic compounds (59.3%) was achieved. However an increase of reaction time up to 60 minutes was not caused a change of COD removal efficiency. However a significant impact of CaO dose on the COD removal efficiency was observed. Increasing the CaO dose from 5 to 25 g/dm3 enabled to increase the degree of COD removal from 22.2 up to 59.3%. On the other hand in the case of ammonia nitrogen removal there was observed a significant impact of reaction time on process efficiency. Extending the reaction time from 1 to 24 hours (17.5 g/dm3 dose of CaO) made it possible to increase the efficiency of ammonia nitrogen removal from 14.3 up to 79.4%.
EN
The preliminary tests of effective COD removal by coagulation-flocculation processes from landfill leachate were carried out. The municipal landfill, from which leachate was collected has been exploited since 2004. The leachate characterized with comparatively low contents of organic matters expressed as COD (2000-2600 mg O2/L), and pH value within the range of 7.4-7.6. The coagulation process was conducted using 3 coagulants: PIX 110-10, Al2(SO4)3 and FeCl3. The applied coagulant doses were within the range of 100-2500 mg/L. In the first part of research the most profitable parameters of coagulation were chosen. It was noted that the ferric coagulants were determined to have bigger treatment efficiency than aluminium sulphate. The highest effectiveness of COD removal (56%) was obtained when FeCl3 was used in dose of 2100 mg/L. The worse efficiency (only about 44%) was observed when Al2(SO4)3 was used in coagulation process in dose of 1550 mg/L. In the second part of research the influence of polielectrolite Magnofloc 156 addition on effectiveness of COD removal was investigated. This research showed that the addition the polielectrolite to coagulation process didn’t significantly improve the treatment effects when the best doses of PIX 110-10 and Al2(SO4)3 were used. However, when FeCl3 was used, the addition of polielectrolite improves the efficiency of COD reduction by about 10%.
PL
Przeprowadzono wstępne badania usuwania zanieczyszczeń organicznych wyrażonych jako ChZT z odcieków składowiskowych za pomocą procesu koagulacji. Miejskie składowisko odpadów, z którego pobierano odcieki, eksploatowane jest od 2004 roku. Odcieki charakteryzowały się stosunkowo niską zawartością związków organicznych (ChZT = 2000-2600 mg O2/dm3) oraz pH w zakresie 7.4-7.6. Proces koagulacji prowadzono przy zastosowaniu 3 koagulantów: PIX 110-10, Al2(SO4)3 oraz FeCl3. Dla każdego koagulantu zastosowano dawki z zakresu 100-2500 mg/dm3. Na podstawie uzyskanych wyników w pierwszej części badań wybrano najkorzystniejsze parametry prowadzenia procesu koagulacji. Stwierdzono, że koagulanty żelazowe powodowały większą efektywność oczyszczania niż siarczan glinu. Największą skuteczność redukcji ChZT (56%) odnotowano przy zastosowaniu FeCl3 w ilości 2100 mg/dm3, natomiast najmniejszą (jedynie około 44%) dla Al2(SO4)3 w ilości 1550 mg/dm3. W drugiej części badań sprawdzono wpływ dodatku polielektrolitu Magnofloc 156 do procesu koagulacji na efektywność oczyszczania. Wyniki badań wykazały, że polielektrolit nie zwiększał w istotnymstopniu efektów oczyszczania, przy zastosowaniu najkorzystniejszych dawek koagulantów PIX 110-10 oraz Al2(SO4)3. Natomiast zastosowanie polielektrolitu wraz z koagulantem FeCl3 zwiększało efektywność oczyszczania o około 10%.
PL
Głównym źródłem zaopatrywania w wodę przeznaczoną do spożycia są wody powierzchniowe. Szacuje się, że w Polsce ok. 50% wody jest pobierane z ujęć powierzchniowych, tj. rzek, jezior i zbiorników zaporowych, z czego ok. 15% stanowią wody infiltracyjne. Aby woda mogła trafić do odbiorców, musi zostać poddana odpowiednim procesom oczyszczania. Do najczęściej stosowanych jednostkowych procesów oczyszczania wody powierzchniowej należą koagulacja i filtracja. Z tego względu w zakładach uzdatniania wody powstają głównie osady pokoagulacyjne. Osady te zawierają wszystkie zanieczyszczenia usuwane z wody surowej pobieranej do oczyszczania, w tym również metale ciężkie. W pracy przedstawiono wyniki badań zawartości metali ciężkich w osadach pokoagulacyjnych powstających w dwóch zakładach uzdatniania wody: Zakładzie Produkcji Wody I (ZPW I) i Zakładzie Produkcji Wody II (ZPW II). Zakłady te różnią się stosowaną technologią oczyszczania wody oraz charakterem zbiorników wody powierzchniowej. Osady do badań pobierano w ciągu całego roku w celu określenia wpływu zmian jakości wody surowej na zawartość metali ciężkich w osadach. Oznaczenie zawartości metali ciężkich: niklu, miedzi, chromu, cynku, kadmu, ołowiu i rtęci wykonano dla zmineralizowanych próbek metodą AAS.
EN
The main sources of water supply for human consumption are the surface water. It is estimated that in Poland about 50% of water is collected from surface water intakes, rivers, lakes and reservoirs, of which about 15% are water infiltration. Raw water must be subjected to appropriate treatment processes before it is directed to human consumption. The most commonly treatment processes used of surface water are coagulation and filtration. Therefore, water treatment plants are precipitated post-coagulation sludge. This post-coagulation sludge contains all the pollution which is removed from treated raw water, including heavy metals. The paper presents the results of researches of contents heavy metals in post-coagulation sludge collected from two water treatment plants: Water Treatment Plant I (WTP I) and Water Treatment Plant II (WTP II). These plants differ in used water treatment technology and the nature of surface water reservoirs. Post-coagulation sludge were taken throughout the year to determine the impact of raw water quality changes on the content of heavy metals in the sludge. Determination of heavy metals: nickel, copper, chromium, zinc, cadmium, lead, mercury was made for the mineralized samples by AAS method.
9
80%
EN
Electroplating coating of products more sustainable coatings is their protection or decoration. As a result of these technological processes generated waste water, which are treatment. During the treatment of waste water produced sludge that were the subject of research. Sludge were from wastewater treatment plants located at the manufacturing plant which produces car parts. They were taken from the sludge tank, preceded by sedimentation in the lamella. In order to determine their sensitivity to dewatering the first step was selected the type and dose of reagent. In the second stage of the study conditioned sludge were tested mechanical dewatering centrifuge and belt press simulator. The results obtained showed that the most effective effect was observed when using anionic polyelectrolytes Praestol 2505 and Superfloc A 110 and A 130. Were used in a dose of 2.1 mg/g TS to 3.4 mg/g TS, and from 8.2 mg/g TS to 15.4 mg/g TS. The use of too low a dose of reagent and overdose resulted in unsatisfactory conditioning effects. The excess polyelectrolyte increased viscosity of the liquid sludge, which gave slower water contained therein. Conditioned selected polyelectrolytes sludge were subjected to a mechanical dewatering. The sludge obtained after centrifugation is characterized by a total solids a maximum of 12.7%. The centrifugation process efficiency was influenced by the spin speed and the duration of the process. The best results were obtained for a duration of 10 min and a speed of 3000 turns/min. A higher degree of dewatering of 29.5% TS obtained using the simulator of belt press.
PL
Galwaniczne pokrywanie wyrobów trwalszymi powłokami stanowi ich ochronę lub dekorację. W wyniku tych procesów powstają ścieki technologiczne, które są oczyszczane. Podczas oczyszczania ścieków powstają osady, które stanowiły przedmiot badań. Osady pochodziły z oczyszczalni ścieków znajdującej się przy zakładzie produkującym części samochodowe. Zostały pobrane ze zbiornika szlamowego, poprzedzonego sedymentacją w osadniku lamelowym. W celu określenia ich podatności na odwadnianie w pierwszym etapie dokonano doboru rodzaju i dawki polieletrolitu. W drugim etapie badań kondycjonowane osady poddano próbom mechanicznego odwadniania w wirówce oraz symulatorze prasy taśmowej. Uzyskane wyniki badań wykazały, że najskuteczniejszy wpływ zaobserwowano w przypadku zastosowania polielektrolitów anionowych Praestol 2505 oraz Superfloc A 110 i A 130. W badaniach zastosowano dawki od 2,1 do 3,4 mg/g s.m. oraz od 8,2 do 15,4 mg/g s.m. Zastosowanie zarówno zbyt małej dawki reagenta, jak i przedawkowanie doprowadziło do uzyskania niezadowalających efektów kondycjonowania. Nadmiar polielektrolitu zwiększył lepkość cieczy osadowej, przez co osad wolniej oddawał zawartą w nim wodę. Kondycjonowane wybranymi polielektrolitami osady zostały poddane procesowi mechanicznego odwadniania. W wyniku wirowania otrzymano osad charakteryzujący się zawartością suchej masy maksymalnie 12,7%. Na efektywność procesu odwirowania miała wpływ prędkość wirowania oraz czas trwania procesu. Najlepsze efekty uzyskano dla czasu wynoszącego 10 min oraz prędkości 3000 obr/min. Wyższy stopień odwodnienia wynoszący 29,5% s.m. uzyskano przy zastosowaniu symulatora pracy taśmowej.
10
80%
EN
Experiments for removal of organic compounds (expressed as COD) from "young" municipal landfill leachate, using oxidation by H 2O2, UV photooxidation and UV/H 2O2 process, were carried out on a laboratory scale. Studies have shown that the most effective method was UV/H 2O2 process. When oxidation was conducted under the most suitable conditions (parameters found during experiments), maximum value of COD removal equaled 74.6%, 19.6% and 19.3% when the treatment was realized by use of H 2O2/UV, H 2O2 and UV radiation, respectively. These results demonstrate that in order to attain high efficiency of COD removal, use of advanced oxidation process (H 2O2/UV) is necessary.
PL
Ścieki pochodzące z przemysłu syntezy chemicznej oczyszczano metodą osadu czynnego w reaktorze SBR. Jako układ porównawczy zastosowano drugi reaktor, w którym oczyszczano ścieki komunalne. Ścieki przemysłowe okazały się znacznie mniej podatne na biodegradację zanieczyszczeń organicznych niż ścieki komunalne. Ponadto ścieki przemysłowe miały negatywny wpływ na proces nitryfikacji, co objawiało się mniejszą efektywnością usuwania azotu ogólnego w porównaniu ze ściekami komunalnymi. Korzystnym rozwiązaniem byłoby wspólne oczyszczanie tych dwóch rodzajów ścieków.
EN
Industrial wastewater was treated with H₂SO₄ or Ca(OH)₂ to adjust pH 7-8.5 and with a Fe salt to coagulate the suspension and then mixed with activated sludge. The municipal wastewater was processed as a ref. The study was carried out for 39 days. A substantial decrease in ammonium N concn. and an increase in the nitrate N concn. were obsd. in both wastewaters. A decrease in COD and BOD was also evidenced. The municipal wastewater showed high ability to nitrification.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.