Introduction: The aim of this work was to study the influence of the applicators used for cervical cancer patients treated with high dose-rate brachytherapy (HDR-BT) in the Maria Sklodowska-Curie National Research Institute of Oncology in Warsaw, Poland on doses in the tumour volumes and organs at risk. Material and methods: The treatment was carried out using Iridium-192 in 4 fractions (7.5 Gy each) given in weekly intervals. Two types of applicators were used for comparison: fletcher and ring. The standard dose distribution parameters, read from the system Oncentra Brachy (version 4.5, Elekta), for bladder, rectum, and sigmoid (D2 cc) and tumour (HR-CTV D100, D98, D90) were studied. Patients were divided into two groups (240 treatment plans) depending on the type of applicator used and into four groups according to the tumour volumes (HR-CTV < 25 cm3 or HR-CTV ≥ 25 cm3). The collected data were analysed using the PQStatSoftware (version 1.8.2). Results: The treatment plans prepared with all types of applicators fulfil the dose distribution requirements, however, the dose delivered to the tumour using the ring applicator was found to be the highest. For the bladder and sigmoid the optimal dose distribution was obtained when using the fletcher applicator, while for the rectum the ring applicator gave the smallest dose value. The D2 cc parameter for sigmoid obtained for fletcher treatment has smaller values in the case of patients with small tumour volume and for this type of applicator was observed a statistically significant difference when compared with the ring. Conclusions: The ring applicator gives the optimal parameters of the dose distribution independently on the tumour volume with respect to the fletcher applicator, which is however more often used in clinical practice.
Purpose: According to the available international recommendations, at least one independent verifi cation of the calculations of number of monitor unit (MU) is required for every patient treated by teleradiotherapy. The aim of this study was to estimate the differences of dose distributions calculated with two treatment planning systems: Eclipse (Varian) and Oncentra MasterPlan (Elekta). Materials and methods: The analysis was performed for 280 three-dimensional conformal radiotherapy treatment (3D-CRT) plans with photon beams from Varian accelerators: CL 600C/D X6 MV (109 plans), CL 2300C/D X6 MV (43 plans), and CL 2300C/D X15 MV (128 plans). The mean doses in the planning target volume (PTV) and doses at the isocenter point obtained with Eclipse and Oncentra MasterPlan (OMP) were compared with Wilcoxon matched-pairs signed rank test. Additionally, the treatment planning system (TPS) calculations were compared with dosimetric measurements performed in the inhomogeneous phantom. Results: Data were analysed for 6 MV plans and for 15 MV plans separately, independently of the treatment machine. The dose values calculated in Eclipse were significantly (p <0.001) higher compared to calculations of OMP system. The average difference of the mean dose to PTV was (1.4 ± 1.0)% for X6 MV and (2.5 ± 0.6)% for X15 MV. Average dose disparities at the isocenter point were (1.3 ± 1.9)% and (2.1 ± 1.0)% for X6 MV and X15 MV beams, respectively. The largest differences were observed in lungs, air cavities, and bone structures. Moreover the variation in dosimetric measurements was less as compared to Eclipse calculations. Conclusions: OMP calculations were introduced as the independent MU verification tool with the first action level range equal to 3.5%.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.