2021 | Vol. 21, no. 3 | 44--62
Tytuł artykułu

Real-time hybrid test of a LNG storage tank with a variable curvature friction pendulum system

Wybrane pełne teksty z tego czasopisma
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
To accurately reproduce the seismic response of the liquefied natural gas (LNG) storage tank equipped with the variable curvature friction pendulum system (VCFPS), a real-time hybrid (RTH) experiment, also known as a real-time substructure experiment, is conducted on it in this study. A typical LNG storage tank with a capacity of 160,000 m3 is employed as the numerical substructure simulated using the MATLAB/Simulink, while the variable curvature friction pendulum bearing (VCFPB) is utilized as the experimental substructure tested using the compression-shear equipment. Thereafter, the validity and feasibility of the RTH experiment are verified using the SAP2000 results. Finally, the working performance of the VCFPB is evaluated scientifically, comprehensively, reasonably, and efficiently. The results show that the VCFPB is very effective in avoiding the resonance phenomenon. It can be seen from the displacement of isolation layer that the VCFPB meets the design requirement. The maximum relative deviations between the RTH test results and the SAP2000 results are 3.45% for the displacement of isolation layer, 4.27% for the base shear, and 1.49% for the liquid sloshing height, respectively. The RTH test is stable and reliable and the predicted results are highly accurate and effective. The RTH test method proves to be accurate in the prediction of the seismic response of the LNG storage tank equipped with the VCFPBs.
Wydawca

Rocznik
Strony
44--62
Opis fizyczny
Bibliogr. 45 poz., fot., rys., tab.
Twórcy
  • Shaanxi Key Laboratory of Safety and Durability of Concrete Structures, Xijing University, Xi’an 710123, China, ShuChaoLin@hotmail.com
  • Postdoctoral Station of Civil Engineering, Tianjin University, Tianjin 300072, China
  • School of Civil Engineering, Lanzhou University of Technology, Lanzhou 730050, China, cewangjx@lut.edu.cn
autor
  • School of Civil Engineering, Harbin Institute of Technology, Harbin 150000, China, 13833185232@139.com
  • Postdoctoral Station of Civil Engineering, Chongqing University, Chongqing 400000, China
  • School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 10055, China, zhaohongtie@hotmail.com
Bibliografia
  • [1] Chang JI, Lin CC. A study of storage tank accidents. J Loss Prev Process Ind. 2006;19:51–9.
  • [2] Azzuni E, Guzey S. Comparison of the shell design methods for cylindrical liquid storage tanks. Eng Struct. 2015;101:621–30.
  • [3] Jiang YY, Zhao ZP, Zhang RF, Domenico DD, Pan C. Optimal design based on analytical solution for storage tank with inerter isolation system. Soil Dyn Earthq Eng. 2020;129:105924.
  • [4] Shrimali MK, Jangid RS. Seismic response of liquid storage tanks isolated by sliding bearings. Eng Struct. 2002;24:909–21.
  • [5] Shrimali MK, Jangid RS. Dynamic analysis of liquid storage tanks with sliding systems. Adv Struct Eng. 2003;6(2):145–58.
  • [6] Wang YP, Teng MC, Chung KW. Seismic isolation of rigid cylindrical tanks using friction pendulum bearings. Earthq Eng Struct Dyn. 2001;30:1083–99.
  • [7] Panchal VR, Jangid RS. Variable friction pendulum system for seismic isolation of liquid storage tanks. Nucl Eng Des. 2008;238:1304–15.
  • [8] Abalı E, Uçkan E. Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings. Soil Dyn Earthq Eng. 2010;30:21–31.
  • [9] Seleemah AA, El-Sharkawy M. Seismic response of base isolated liquid storage ground tanks. Ain Shams Eng J. 2011;2:33–42.
  • [10] Zhang RF, Weng DG, Ren XS. Seismic analysis of a LNG storage tank isolated by a multiple friction pendulum system. Earthq Eng Eng Vib. 2011;10:253–62.
  • [11] Panchal VR, Jangid RS. Seismic response of liquid storage steel tanks with variable frequency pendulum isolator. KSCE J Civ Eng. 2011;15(6):1041–55.
  • [12] Soni DP, Mistry BB, Panchala VR. Double variable frequency pendulum isolator for seismic isolation of liquid storage tanks. Nucl Eng Des. 2011;241:700–13.
  • [13] Takanashi K, Udagawa K, Seki M, Okada T, Tanaka H. Nonlinear earthquake response analysis of structures by a computer-actuator on-line system: Part 1 detail of the system. Trans Archit Inst Jpn. 1975;229:77–83.
  • [14] Nakashima M, Kato H, Takaoka E. Development of real-time pseudo dynamic testing. Earthq Eng Struct Dyn. 1992;21:79–92.
  • [15] Kim NS, Lee DG. Pseudodynamic test for evaluation of seismic performance of base-isolated liquid storage tanks. Eng Struct. 1995;17(3):198–208.
  • [16] Dion C, Bouaanani N, Tremblay R, Lamarche CP, Leclerc M. Real-time dynamic substructuring testing of viscous seismic protective devices for bridge structures. Eng Struct. 2011;33:3351–63.
  • [17] Verma M, Rajasankar J. Improved model for real-time substructuring testing system. Eng Struct. 2012;41:258–69.
  • [18] McCrum DP, Broderick BM. Evaluation of a substructured soft-real time hybrid test for performing seismic analysis of complex structural systems. Comput Struct. 2013;129:111–9.
  • [19] Lin SC. VCFPB base isolation and prestressed tendon construction research for LNG storage tank, PhD thesis. Beijing University of Technology, Beijing, China, 2016.
  • [20] Lima TA, de Almeida Filho MP, Torrico BC, Nogueira FG, Correia WB. A practical solution for the control of time-delayed and delay-free systems with saturating actuators. Eur J Control. 2020;51:53–64.
  • [21] Jung RY, Shing PB. Performance evaluation of a real-time pseudodynamic test system. Earthq Eng Struct Dyn. 2006;35:789–810.
  • [22] Li ZB, Lin SC, Yu CY, Gao Y. A new bidirectional variable curvature friction pendulum bearing. 2018, China patent No. ZL201510253016.8 (in Chinese).
  • [23] Lin SC, Han JQ, Zhao HT. Experimental and theoretical studies of bidirectional variable curvature friction pendulum bearing. KSCE J Civ Eng. 2020;24(5):1568–80.
  • [24] Tsai CS, Chiang TC, Chen BJ. Finite element formulations and theoretical study for variable curvature friction pendulum system. Eng Struct. 2003;25:1719–30.
  • [25] Constantinou M, Mokha A, Reinhorn A. Teflon bearings in base isolation II: modeling. J Struct Eng. 1990;116(2):455–74.
  • [26] Lupășteanu V, Soveja L, Lupășteanu R, Chingălată C. Installation of a base isolation system made of friction pendulum sliding isolators in a historic masonry orthodox church. Eng Struct. 2019;188:369–81.
  • [27] Cancellara D, Angelis FD. Nonlinear dynamic analysis for multi-storey RC structures with hybrid base isolation systems in presence of bi-directional ground motions. Compos Struct. 2016;154:464–92.
  • [28] Martí J, Crespo M, Martínez F. Seismic isolation of liquefied natural gas tanks: a comparative assessment. Seism Isol Prot Syst. 2010;1(1):125–40.
  • [29] Lu LY, Lee TY, Yeh SW. Theory and experimental study for sliding isolators with variable curvature. Earthq Eng Struct Dyn. 2011;40:1609–27.
  • [30] Mokha A, Constantinou M, Reinhorn A. Teflon bearings in base isolation I: testing. J Struct Eng. 1990;116:438–54.
  • [31] Xue SD, Li XY, Cai YC. Experiments on a new type of seismic isolation bearing combined with Teflon frictional sliding system and springs. J Beijing Univ Technol. 2009;35(2):168–73 (in Chinese).
  • [32] Ji XD, Kajiwara K, Nagae T, Enokida R, Nakashima M. A substructure shaking table test for reproduction of earthquake responses of high-rise buildings. Earthq Eng Struct Dyn. 2009;38(12):1381–99.
  • [33] Fermandois GA. Application of model-based compensation methods to real-time hybrid simulation benchmark. Mech Syst Signal Process. 2019;131:394–416.
  • [34] Chen C, Ricles JM, Marullo TM, Mercan O. Real-time hybrid testing using the unconditionally stable explicit CR integration algorithm. Earthq Eng Struct Dyn. 2009;38:23–44.
  • [35] Chen C, Ricles JM. Analysis of actuator delay compensation methods for real-time testing. Eng Struct. 2009;31:2643–55.
  • [36] Darby AP, Blakeborough A, Williams MS. Improved control algorithm for real-time substructure testing. Earthq Eng Struct Dyn. 2001;30(3):431–48.
  • [37] Darby AP, Williams MS, Blakeborough A. Stability and delay compensation for real-time substructure testing. J Eng Mech. 2002;128(12):1276–84.
  • [38] Chen C, Ricles JM. Improving the inverse compensation method for real-time hybrid simulation through a dual compensation scheme. Earthq Eng Struct Dyn. 2009;38:1237–55.
  • [39] Fu B, Kolay C, Ricles J, Jiang HJ, Wu T. Stability analysis of substructure shake table testing using two families of model-based integration algorithms. Soil Dyn Earthq Eng. 2019;126:105777.
  • [40] SAP2000. CSI analysis reference manual. Computers and Structures, Inc., 2009.
  • [41] Wilson EL. Three-dimensional static and dynamic analysis of structures: a physical approach with emphasis on earthquake engineering. Berkeley: Computers and Structures Inc; 2002.
  • [42] Compagnoni ME, Curadelli O, Ambrosini D. Experimental study on the seismic response of liquid storage tanks with sliding concave bearings. J Loss Prev Process Ind. 2018;55:1–9.
  • [43] Pranesh M, Sinha R. Aseismic design of structure equipment systems using variable frequency pendulum isolator. Nucl Eng Des. 2004;231:129–39.
  • [44] Ge SJ, Wang W, Pan CP, Peng ZY, Zhao ZY, Shi CJ, Wang YX, Wang JQ, Liu L, Sun HL. A new variable curvature friction pendulum bearing with self-adaptive function. 2015, China patent No. ZL201310220186.7 (in Chinese).
  • [45] Wu B, Wang QY, Shing PB, Ou JP. Equivalent force control method for generalized real-time substructure testing with implicit integration. Earthq Eng Struct Dyn. 2007;36:1127–49.
Uwagi
PL
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2022-2023)
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-fbf5824f-d54a-4358-8680-7636d53aa314
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.