Fifteen years ago, the Epstein frame to the independent Single Sheet Tester (SST92) relation was determined using a large number of correlated grain-oriented samples [1], and the results are reflected in Annex C of IEC standard 60404-3 [2]. Whilst those results were achieved using the same equipment of one reference laboratory, the new data originate from measurements on sample pairs from different manufactures using their own measuring equipment. The resulting Epstein to SST92 ratios show slightly higher values than the old ones, and a considerable dispersion. The reasons for these phenomena are discussed and further experiments for their clarification proposed.
PL
Piętnaście lat temu zaprezentowano porównanie wyników badań różnych próbek blach elektrotechnicznych wykonanych metoda Epsteina i przy wykorzystaniu testera próbek arkuszowych SST92. Wyniki pochodziły z badania próbek w tym samym laboratorium. Nowe wyniki zaprezentowane w pracy przedstawiają badania różnych próbek w różnych laboratoriach. Otrzymano nieco większy rozrzut zmierzonych wartości. W artykule analizuje się przyczyny tych różnic.
Wydawca

Rocznik
Strony
1--3
Opis fizyczny
Bibliogr. 8 poz., wykr.
Twórcy
autor
autor
  • Thyssenkrupp Electrical Steel, Isbergues
autor
  • Cogent-Power, Newport
autor
  • Wuhan Iron and Steel Corp.
autor
  • Thyssenkrupp Electrical Steel Bochum
autor
  • AK Steel, West Chester
autor
  • Thyssenkrupp Electrical Steel. Gelsenkirchen
autor
  • Baosteel Corp., Shanghai
Bibliografia
  • [1] J. Sievert: The Measurement of Magnetic Properties of Electrical Sheet Steel – Survey of Methods and Standards. SMM14, J.Magn.Magn. Mater 215-216 (2000) 647-651
  • [2] IEC Publ.60404-3 Ed. 2.2 (2010): Magnetic materials – Part 3: Methods of measurement of the magnetic properties of electrical steel strip and sheet by means of a single sheet tester.
  • [3] IEC Publ.60404-2 Ed. 3.1 (2008): Magnetic materials – Part 2: Methods of measurement of the magnetic. properties of electrical steel strip and sheet by means of an Epstein frame.
  • [4] J. Sievert, H. Yang, P. Zhang and H. Ge: Studies on the systematic error of Epstein measurements. XII. Int. Workshop on 1- and 2-dim. magnetic measurements and testing, Vienna 2012, submitted for publication in the IJAEM
  • [5] J.Sievert, H. Ahlers: Epstein to SST relationship – statistical rather than deterministic. XI. Int. Workshop on 1- and 2-dim. magnetic measurements and testing, Oita 2010, Electrical Review vol 9b/2011,R.87, p.17-19
  • [6] J. Sievert, H. Ahlers:Is the Epstein frame replaceable? SMM9 Conference, Madrid 1989, Anales de Fisica Serie B, vol. 86 (1990), p. 58-63
  • [7] J. Sievert, H. Ahlers, F. Fiorillo, M. Hall , L. Henderson and L. Rocchino: Magnetic measurements on electrical steels using epstein and sst methods - euromet comparison between standard laboratories. Procs. of the 6th Int.Workshop on 1&2- dimensional measurement and testing, Bad Gastein, Sept. 2000, ed. H. Pfützner, Vienna Magnetic Groups Reports, ISBN 3-902105-00-3, Vienna 2002, p. 194-203
  • [8] J. Sievert, H. Ahlers, P. Brosin, M. Cundeva and J. Luedke: Relationship of Epstein to SST Results for Grain-Oriented Steel. 9th ISEM Conference, Pavia, Italy, May 1999, in: A.Savini (editor):Non-Linear Electromagnetic Systems, Advanced Techniques and Mathematical Methods, Studies in Applied Electromagnetics and Mechanics, IOS Press, Amsterdam, Niederlande, Vol. 18(2000)3-6
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-c4fb9d8f-601d-4e47-8881-a3efb5e8a7e2
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.