EN
The relationship between the measurement results of Epstein frame and Single Sheet Tester (SST) method are of increasing interest since, for technical and economical reasons, manufacturers and users of electrical sheet steel use more and more the SST for grading and quality control of this material. Besides the systematic deviations between these two methods, there is a considerable statistical component in that relationship. This paper is to demonstrate this phenomenon on the basis of the statistical characteristics of former international round robin tests and dispersion characteristics of material production estimated from the internal dispersions within 55 groups of Epstein samples from 9 manufacturers, each group being constituted of 4 or 5 samples of one grade from one manufacturer. The resulting total dispersion is slightly higher than that of a previous corresponding study accomplished in one laboratory.
PL
Zależność między wynikami badań aparatem Epsteina a testerem próbek arkuszowych SST może mieć duże znaczenie praktyczne ponieważ coraz więcej ośrodków stosuje wymiennie tylko jedną z tych metod. Obok różnic fundamentalnych (zasady fizycznej) ważne sa też badania statystyczne różnic między tymi metodami. W artykule zaprezentowano międzynarodowe porównania różnych urządzę pomiarowych - badania wykonywano na różnych rodzajach próbek. Wyniki wskazują że różnice są większe niż w przypadku wcześniej demonstrowanych różnic między badaniami w jednym laboratorium.
Wydawca

Rocznik
Strony
17-19
Opis fizyczny
Bibliogr. 10 poz., rys., tab., wykr.
Twórcy
autor
autor
Bibliografia
  • [1] IEC publ. 60404-2 Ed.3.0 (1996) (amended version Ed.3.1 (2008)). Magnetic Materials – Part 2: Methods of measurement of the magnetic properties of electrical steel strip and sheet by means of an Epstein frame
  • [2] IEC publ. 60404-3 Ed.2.0 (1992) (amended version Ed.2.2 (2010)). Magnetic Materials – Part 3: Methods of measurement of the magnetic properties of electrical steel sheet and strip by means of a Single Sheet tester.
  • [3] Girgis, R, K. Gramm , J. Sievert and M.G.Wickramasekara: SMM 12 Conference, Grenoble 1997; Journal de Physique IV France 8 (1998), p.Pr2-729 – Pr2-232
  • [4] Internal IEC document IEC 68/413/INF; for supply contact johannes.sievert@t-online.de
  • [5] Drake, A.E.;. EU-report No. EUR 10233, Brussels 1985
  • [6] Sievert, J., H. Ahlers, F. Fiorillo, M. Hall , L. Henderson and L. Rocchino, Proc.6th Int.Workshop on 1&2-dimensional measurement and testing, Bad Gastein Sept. 2000, ed. H. Pfützner, Vienna Magn.Groups Reps, ISBN 3-902105-00-3, Vienna 2002, 194-203
  • [7] Drake, A.E and C.Ager: Synthesis report on an intercomparison of a.c. magnetic measurements on electrical sheet steels using a single sheet tester. EU-report, Brussels 1989; Histogram see: Sievert, J., M. Binder and L. Rahf, SMM9 Conference Madrid 1989, Anales de Fisica ser. B, 86(1990) 76 or Sievert,J.,IEEE Trans.MAG 26(Sept. 1990) 2553-2558
  • [8] J. Sievert, H. Ahlers, P. Brosin, M. Cundeva and J. Luedke:Studies in Applied Electromagnetics and Mechanics, IOS Press, Amsterdam, Niederlande, Vol. 18(2000)3-6
  • [9] J. Sievert: The Measurement of Magnetic Properties of Electrical Sheet Steel - Survey on Methods and Situation of Standards. SMM 14 Conference, Balatonfuereds, Hungary, September 1999, Paper No. I/7-2.43, J.Magn.Magn. Mater 215- 216 (2000) 647-651
  • [10] Guidelines for the Expression of the Uncertainty of Measurement in Calibrations. WECC Doc. 19-1990