Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2006 | Vol. 55, no 2 | 95-108
Tytuł artykułu

Calibration of very close range digital cameras

Warianty tytułu
PL
KaIibracja kamer cyfrowych bardzo bliskiego zasięgu
Języki publikacji
EN
Abstrakty
EN
The paper discusses the problems of the calibration process of very close range semi-metric digital cameras. Using such cameras for precise measurement of small objects, the photographs have to be taken at a very large scale, ranging from 1 :20 to 1 :50. To ensure the submillimetre accuracy of the photogrammetric measurement, the specific calibration tests and procedures for determination of the interior orientation parameters, including the coefficients for image systematic errors, must be applied. The results of two calibration approaches, based on 3D and 2D calibration tests, have been presented in the paper. The experiment is a part of the research project concerning the numerical modelling of small 3D fragments of the broken archaeological items for reconstruction of the context of the archaeological monument.
PL
Artykuł dotyczy procesu kalibracji semi-metrycznych kamer cyfrowych. Stosując takie kamery do pomiaru małych obiektów, zdjęcia muszą być wykonane w bardzo dużej skali, w zakresie od około 1:20 do 1:50. W celu zapewnienia dokładności pomiaru fotogrametrycznego na poziomie poniżej pół milimetra, należy stosować specjalne procedury i testy kalibracyjne dla określenia parametrów orientacji wewnętrznej, łącznie ze współczynnikami opisującymi błędy systematyczne zdjęć. W niniejszym artykule, przedstawiono porównanie dwóch metod, bazujących na obrazach dwuwymiarowych i trójwymiarowych testów kalibracyjnych. Wykonany eksperyment jest częścią projektu badawczego, finansowanego przez KBN, który dotyczy numerycznego modelowania fragmentów rzeźb w celu rekonstrukcji oryginalnego kontekstu zabytku.
Wydawca

Rocznik
Strony
95-108
Opis fizyczny
Bibliogr. 20 poz., rys., tab., wykr.
Twórcy
autor
  • Institute of Photogrammetry and Cartography Warsaw University of Technology I Plac Politechniki, 00-661 Warsaw, Poland, abujak7@wp.pl
Bibliografia
  • Bujakiewicz A., (1984): Usefulness of Long Focus non Metric Cameras in Precise Measurements, International Archives of ISPRS, Vol. XXV, B5, pp. 136-140.
  • Bujakiewicz A, Kowalczyk M., Podlasiak P., Zawieska D., (2004): Modelling and Visualization of Three Dimensional Objects Using Close Range Imagery, The International Archives for Photogrammetry,Remote Sensing and Spatial Information Sciences, Vol. XXXV, B5, pp. 442-446.
  • Bujakiewicz A., Kowalczyk M., Podlasiak P., Zawieska D., Rzepka S., (2004-2006): The research project Tl2 E 033 26, on "Numerical modelling of the fragments of the archaeological pieces for the reconstruction of the original context of the relic", supported by the Polish State Committee for Scientific Research, Reports for 2004 and 2005, Institute of Photogrammetry and Cartography, Warsaw University of Technology.
  • Cardenal J., Mata E., Castro P., Delgado J., Hernandes N.A, Peres J.L., Ramos M., Torres M., (2004): Evaluation of a Digital Non Metric Camera (Canon D30) for the Photogrammetric Recording of Historical Buildings, Archives of Photogrammetry and Remote Sensing, Vol. XXXV, B5, pp. 445-460.
  • Devernay F., Faugeras O., (2001): Straight lines have to be straight. Automatic calibration and removal of distortion from scenes of structured environments, Machine Vision and Applications 13, pp. 14-24.
  • Faig W., (1975): Calibration of Close Range Photogrammetric Systems - Mathematical Formulation, Archives of XIII ISPRS Congress, Helsinki, pp. 1479-1486.
  • Gomez Lahoz J., Cuadrado Mendez O. Martinez Rubio J., (2004): Lens Distortion Simulation, an Application for Understanding Geometric Distortion, Archives of Photogrammetry and Remote Sensing, Vol. XXXV, B5, Supplement.
  • Grammatikopoulos L., Karras G., Petsa E., (2004): Camera calibration combining images with two vanishing points, Archives of Photogrammetry and Remote Sensing, Vol. XXXV, B5, pp. 99-104.
  • Habrouk H.E., Li X.P., Faig W., (1996): Determination of Geometric Characteristics of a Digital Camera by Self-Calibration, International Archives of Photogrammetry and Remote Sensing, Vol. XXXI, Part BI, Vienna, pp. 60-64.
  • Habib AP., Ghanma R.J., Kim E.M., (2004): 3D Modelling of Historical Sites using Low Cost Digital Cameras, Archives of Photogramnmetry and Remote Sensing, Vol. XXXV, B5, pp. 570-575.
  • Kager H., Rottensteiner F., Kerschner M., Stadler T., (2002): ORPHEUS 3.2.1 User Manual, Institute of Photogrammetry and Remote Sensing, Vienna University of Technology.
  • Karara H.M., (1972): Simple Cameras for Close Range Applications, Photograrnmetric Engineering, Vol. 38, No 5.
  • Kowalczyk M., (2003): Investigation on Possibilities of Automation in Photogrammetric Measurement with use of Digital Camera (in Polish), PhD theses, Institute of Photogrametry and Cartography, Warsaw University of Technology (133 pp).
  • McIntosh K., (1996):. A Calibration Procedure for CCD Array Cameras, International Archives of Photogrammetry and Remote Sensing, Vol. XXXI, Part Bl, Vienna, pp. 138-143.
  • Parmehr E.G., Azizi A., (2004): A comparative evaluation of the potential of close range photogrammetric technique for the 3D measurement of the body of a Nissan petrol car, Archives of Photogrammetry and Remote Sensing, Vol. XXXV, B5, pp. 110-113.
  • Podlasiak P., (2004): Determination of Camera Distortion on the Basis of Images of the Natural Objects (in Polish), Archiwum Fotogrametrii, Kartografii i Teledetekcji, Vol. 14, pp. 459-466.
  • Sawicki P., (2001): Solution of Terratriangulation with Self-calibration of Digital Camera Kodak DC4800 (in Polish), Archiwum Fotogrametrii, Kartografii i Teledetekcji, Vol. II, pp. 3/25-3/32.
  • Tokarczyk R., (1982): lnvestigation on the Use of Non-metric Cameras in Precise Measurements for Engineering (in Polish), PhD theses, Faculty of Mining Surveying and Environmental Engineering, AGH - University of Science and Technology in Cracow (87 pp).
  • Tokarczyk R., Boroń A., (2000): lnvestigation on the Use of Non-metric Cameras for Photogrammetric Applications (in Polish), Archiwum Fotogrametrii, Kartografii i Teledetekcji, Vol. 10, pp. 63/1-63/10.
  • Xie W., Zhang Z., Zhang J., (2004): Multi based camera calibration without control point, Archives of Photograrnmetry and Remote Sensing, Vol. XXXV, B5, pp. 36-41.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ2-0022-0006
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.