Warianty tytułu
Języki publikacji
Abstrakty
Two types of analytical microsystems for the detection of species of interest in biomedical diagnosis and in environmental monitoring are specifically described in this paper. We describe a novel device that will measure whole blood concentration of D-dimer, a recognized biomarker of increased blood clotting activity and that will then offer opportunity to use the test in the point of care setting. The device combines innovation in antibody bio-engineering for high specificity immunoassay-based diagnostics and nano/micro engineered impedimetric analysis electrodes incorporating a biocompatible polymer substrate with development of a disposable microfluidic manifold, enabling diagnostics at the point-of-first-contact. The feasibility of a generic microsystem integrating a microfluidic system of concentration and a module of electrochemical detection is demonstrated for the four metals of the European directive (OCE 2000/GO/EC) for the quality of water resource: cadmium, mercury, lead and nickeI.
Czasopismo
Rocznik
Tom
Strony
3-16
Opis fizyczny
Bibliogr. 40 poz., rys., wykr.
Twórcy
autor
autor
- University of Lyon, Laboratory of Analytical Sciences, Claude Bernard University Lyon 1, Building CPE, 43 Boulevard 11 Novembre 1918, 69622 Villeurbanne Cedex, France, nicole.jaffrezic@univ-lyon1.fr
Bibliografia
- 1. Heit J. A., Melton L. J. 3rd, Lohse C. M. et al.: Incidence of venous thromboembolism in hospitalized patients vs community residents. Mayo Clin. Proc. 2001, 76 (11), 1102-1110.
- 2. White R. H.: The epidemiology of venous thromboembolism. Circulation 2003, 107, (23 Suppl. 1), I4-8.
- 3. Fowkes F. J., Price J. F., Fowkes F. G.: Incidence of diagnosed deep vein thrombosis in the general population: systematic review. Eur. J. Vasc. Endovasc. Surg. 2003, (1) 25, 1-5.
- 4. Anderson F. A. Jr., Wheeler H. B., Goldberg R. J. et al.: A population based perspective of the hospital incidence and case-fatality rates of deep vein thrombosis and pulmonary embolism. The Worcester DVT Study. Arch. Intern. Med. 1991, 151 (5), 933-938.
- 5. Segal J. B., Eng J., Jenckes M. W. et al.: Diagnosis and Treatment of Deep Venous Thrombosis and Pulmonary Embolism. Evidence Report/Technology Assessment No. 68. Rockville, Md: Agency for Healthcare Research and Quality. March 2003. AHRQ publication 03-E016.
- 6. Finnish Medical Society Duodecim. Deep venous thrombosis. Helsinki, Finland: Duodecim Medical Publications Ltd; 2002. Available at: http://www.ebm-guidelines.com.
- 7. American College of Emergency Physicians-Medical Specialty Society. Clinical policy: critical issues in the evaluation and management of adult patients presenting with suspected lower-extremity deep venous thrombosis. Ann. Emerg. Med. 2003, 42, 124-135.
- 8. Wells P. S., Anderson D. R., Bormanis J. et al.: Value of assessment of pretest probability of deep-vein thrombosis in clinical management. Lancet 1997, 350, 1795-1798.
- 9. Wells P. S., Hirsh J., Anderson D. R. et al.: A simple clinical model for the diagnosis of deep vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process. J. Intern. Med. 1998, 243, 15-23.
- 10. Kelly J., Rudd A., Lewis R. R., Hunt B. J.: Plasma D-dimers in the diagnosis of venous thromboembolism. Arch. Intern. Med. 2002, 162, 747-756.
- 11. Hansson P. O., Eriksson H., Eriksson E. et al.: Can laboratory testing improve screening strategies for deep vein thrombosis at an emergency unit? J. Intern. Med. 1994, 235, 143-151.
- 12. Kearon C., Ginsberg J. S., Douketis J. et al.: Management of suspected deep vein thrombosis in out patients by using clinical assessment and D-dimer testing. Ann. Intern. Med. 2001, 135, 108-111.
- 13. Kearon C., Ginsberg J. S., Douketis J. et al.: Diagnosis of a first DVT in outpatients: interim analysis of a management study based on clinical evaluation and D-dimer results. Thromb. Haemost. 1997, 78, 588.
- 14. Wells P. S., Anderson D. R., Ginsberg J.: Assessment of deep vein thrombosis or pulmonary embolism by the combined use of clinical model and noninvasive diagnostic tests. Semin. Thromb. Hemost. 2000, 26, 643-656.
- 15. Michiels J. J., Freyburger G., Van Der Graaf F. et al.: Strategies for the safe and effective exclusion and diagnosis of deep vein thrombosis by the sequential use of clinical score, D-dimer testing and compression ultrasonography. Semin. Thromb. Hemost. 2000, 26, 657-667.
- 16. Gerard M., Chaubey A., Malhotra B. D.: Application of conducting polymers to biosensors. Biosens. Bioelectron. 2002, 17, 345-359.
- 17. Chou S. Y., Krauss P. R., Renstrom P. J.: Imprint of sub-25 nm vias and trenches in polymers. Appl. Phys. Lett. 1995, 67, 3114-3116; Chou S. Y., Krauss P. R., Renstrom P. J.: Imprint lithography with 25-nanometer resolution. Science 1996, 272, 85-87.
- 18. Tseng A. A.: Recent developments in micromilling using focused ion beam technology. J. Micromech. Microeng. 2004, 14, R15-R34.
- 19. Lang W.: Silicon microstructuring technology. Mater. Sci. Eng. R: Reports 1996, 17, 1-55.
- 20. Gerwen P. V., Laureyn W., Laureys W., Huyberechts G., De Beeck M. O., Baert K., Suls J., Sansen W., Jacobs P., Hermans L., Mertens R.: Nanoscaled Interdigitated Electrode Arrays for Biochemical Sensors. Sens. Act. B: Chem. 1998, 49, 73-80.
- 21. Kleps I., Angelescu A., Miu M.: Measurement systems based on metal / dielectric nanostructures for electrochemical analyses. Mater. Sci. Eng. C. 2002, 19, 219-223; Moretto L. M., Pepe N., Ugo P.: Voltammetry of redox analytes at trace concentrations with nanoelectrode ensembles. Talanta 2004, 62, 1055-1060.
- 22. Cosnier S.: Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. Biosens. Bioelectron. 1999, 14, 443-456.
- 23. Saxena V., Malhotra B. D.: Porspect of conducting polymers in molecular electronics. Curr. Appl. Phys. 2003, 3, 293-305.
- 24. Geetha S., Raoa C. R. K., Vijayana M., Trivedi D. C.: Biosensing and drug delivery by polypyrrole. Anal. Chim. Acta, 2006, 568, 119-125; Ramanavičius A., Ramanavičienė A., Malinauskas A.: Electrochemical Sensors Based on Conducting polymer - Polypyrrole (Review). Electrochim. Acta 2006, 51, 6025-6037.
- 25. Zhang D., Wang Y.: Synthesis and applications of one-dimensional nano-structured polyaniline. An overview. Mater. Sci. Eng. B. 2006, 134, 9-19.
- 26. Love J. C., Estroff L. A., Kriebel J. K., Nuzzo R. G., Whitesides G. M.: Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology. Chem. Rev. 2005, 105, 1103-1169; Martelet C., Jaffrezic-Renault N., Hou Y., Errachid A., Bessueille F.: Self Assembled Monolayers for biosensing, Biosensors: Electrochemical and Mechanical Biosensors (Methods Express), Paul Millner (Ed.) Scion Publishing UK, ISBN, 1904842127.
- 27. Hou Y., Helali S., Zhang A., Jaffrezic-Renault N., Martelet C., Minic J., Gorojankina T., Persuy M-A., Pajot-Augy E., Salesse R., Bessueille F., Samitier J., Errachid A., Akinov V., Reggiani L., Pennetta C., Alfinito E.: Immobilization of rhodopsin on a self-assembled multilayer and its specific detection by electrochemical impedance spectroscopy. Biosens. Bioelectron. 2006, 21, 1393-1402.
- 28. Xia Y., Whitesides G. M.: Soft Lithography. Angew. Chem. Int. Ed. 1998, 37, 550-575.
- 29. Renault J. P., Bernard A., Bietsch A., Michel B., Bosshard H. R., Delamarche E., Kreiter M., Hecht B., Wild U. P.: Fabricating arrays of single proteins on glass using microcontact printing. J. Phys. Chem. B., 107, 703-711, 2003.
- 30. Piner R. D., Zhu J., Xu F., Hong S., Mirkin C. A.: "Dip-Pen" Nanolithography. Science 1999, 283, 661-663.
- 31. Pejcica B., De Marco R.: Impedance spectroscopy: Over 35 years of electrochemical sensor optimization. Electrochim. Acta 2006, 51, 6217-6229; Minic J., Grosclaude J., Aioun J., Persuy M-A., Gorojankina T., Salesse R., Pajot-Augy E., Helali S., Hou Y., Jaffrezic-Renault N., Bessueille F., Errachid A., Gomila G., Ruiz O., Samitier J.: Immobilization of native membrane-bound rhodopsin on biosensor surface. Biochim. Biophys. Acta 2005, 1724, 324-332.
- 32. Ouerghi O., Touhami A., Jaffrezic-Renault N., Martelet C., Ben Ouada H., Cosnier S.: Electrodeposited biotinylated polypyrrole as immobilization method for impedimetric immunosensors. IEEE Sensors Journal 2004, 4, (5), 559-567.
- 33. Tlili C., Korri-Youssoufi H., Ponsonnet C., Martelet C., Jaffrezic-Renault N. J.: Electrochemical impedance probing of DNA hybridisation on oligonucleotide-functionalised polypyrrole. Talanta 2005, 68, 131-137.
- 34. Ameur S., Martelet C., Jaffrezic-Renault N., Chovelon J. M.: Sensitive immunodetection through impedance measurements onto gold functionalized electrodes. Appl. Bioch.Biotechn. 2000, 89, (2-3), 161-170.
- 35. Sarrut N.: Dispositif microfluidique dans lequel l'interface liquide/fluide est stabilisée. Brevet CEA 2002, EN 02 15254.
- 36. Sarrut N.: Dispositif pour la connexion de capillaires a un composant de microfluidique. Brevet CEA 2002, FRA 0102803.
- 37. El Tall O., Jaffrezic-Renault N., Sigaud M., Vittori O.: Anodic stripping voltammetry of heavy metals at nanocrystalline boron-doped diamond electrode. Electroanalysis 2007, 19, 1152-1159.
- 38. Mizuochi N., Ogura M., Watanabe H., Isoya J., Okushi H., Yamasaki S.: EPR study of hydrogenrelated defects in boron-doped p-type CVD homoepitaxial diamond films. Diamond Relat. Mater. 2004, 11, 2096-2099.
- 39. Schneider D., Meyer C. F., Mai H., Schoneich B., Ziegele H., Scheibe H. J., Lifshitz Y.: Non-destructive characterization of mechanical and structural properties of amorphous diamond-like carbon films 1. Diamond Relat. Mater. 1998, 7, 973-980.
- 40. Khadro B., Sikora A., Loir A.-S., Errachid A., Garrelie F., Donnet C., Jaffrezic-Renault N.: Electrochemical performances of B doped and undoped diamond-like carbon (DLC) films deposited by femtosecond pulsed laser ablation for heavy metal detection using square wave anodic stripping voltammetric (SWASV) technique. Sensors and Actuators B (in press) doi:10.1016/j.snb.2010.11.034.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BPZ1-0073-0009