2008 | Vol. 53, No. 6 | 861-875
Tytuł artykułu

Use of the Bayesian concept for the calculation of characteristic limits in radioanalytical methods

Autorzy
Wybrane pełne teksty z tego czasopisma
Warianty tytułu
PL
Zastosowanie koncepcji Bayesowskiej do obliczania charakterystycznych granic w metodach radioanalitycznych
Języki publikacji
EN
Abstrakty
EN
Presented are procedures based on modern Bayesian statistics which are used to calculate characteristic limits, i.e. the decision threshold, detection limit and confidence limit in radioanalytical methods. Indicated are also the key elements of this statistics which can be used for measurement of ionizing radiation. The attached example of instrumental neutron activation analysis provides an illustration of the issues discussed.
PL
Przedstawiono procedury postępowania, oparte na nowoczesnej statystyce bayesowskiej, stosowane do obliczania granic charakterystycznych tzn. progu decyzji, granicy detekcji i granic ufności w metodach radioanalitycznych.Podano także podstawowe elementy tej statystyki w aspekcie jej wykorzystania w pomiarach promieniowania jonizującego. Załączony przykład z instrumentalnej neutronowej analizy aktywacyjnej ilustruje omówione zagadnienie.
Wydawca

Czasopismo
Rocznik
Strony
861-875
Opis fizyczny
Bibliogr. 23 poz.
Twórcy
Bibliografia
  • 1.Jaynes E.T., Probability Theory: The Logic of Science, Cambridge, Cambridge University Press 2003.
  • 2.Lira 1., Wöger W., Comparison Between the Conventional and Bayesian Approaches to Evaluate Data, Metrologia, 43, S249(2006).
  • 3.ISO 1993 Guide to the Expression of Uncertainty in Measurement, revised and reprinted 1995, Geneva, International Organization for Standardization
  • 4.ISO 11929-7, Determination of the Detection Limit and Decision Threshol dfor Ionizing Radiation Measurements. Part 7: Fundamentals and Genera Applications, Geneva: ISO (2005).
  • 5.Michel R., Quality Assurance of Nuclear Analytical Techniques Based on Bayesian Characteristic Limits, J. Radioanal. Nucl. Chem., 245,137 (2000).
  • 6.Weise K., Hübel K., Rose E., Schlager M., Schrammel D., Täschner M., Michel R., Bayesian Decision Threshold, Detection Limit and Confidence Limits in Ionising-Radiation Measurement,Radiat. Prot. Dosim., 121, 52 (2006).
  • 7.Altschuler B., Pasternack B., Statistical Measures of the Lower Limit of Detection of a Radioactivity Counter, Health Phys., 9,293 (1963).
  • 8.Nicholson W. L., Fixed Time Estimation of Counting Rates with Background Corrections, Handford Laboratories ( 1963).
  • 9.Currie L. A., Limits for Qualitative Detection and Quantitative Determination, Anal. Chem., 40, 586(1968).
  • 10.Sterlinski S., The Lower Limit of Detection for Short-Lived Radioisotopes, Nucl. Instr. Meth., 42, 219(1966).
  • 11.Sterlinski S., The Lower Limit of Detection for Very Short-Lived Radioisotopes Used in Activation Analysis, Nucl. Instr. Meth., 68, 341 (1969).
  • 12.Miller G., Inkret W.C. Marrtz H F., Bayesian Detection Analysis for Radiation Exposure, I and II, Rad. Prot. Dosim., 48, 115 (1995).
  • 13.Little R J. A., The Statistical Analysis of Low-Level Radioactivity in the Presence of Background Counting, Health Phys., 43,693 (1982).
  • 14.Weise K., Wöger W., A Bayesian Theory of Measurement Uncertainty, Meas. Sci. Technol., 3, 1 (1992).
  • 15.Weise K., Bayesian-Statistical Decision Threshold, Detection Limit and Confidence Interval in Nuclear Radiation Measurement, Kerntechnik, 63,214 ( 1998).
  • 16.Commission Recommendation of 18 Dec. 2003 Regarding the Standard Information on Airborne and Liquid Radioactive Discharges into the Environment From Nuclear Power Reactors and Reprocessing Plants in Normal Operating Conditions, OJ L.2/37, 6.1.2004.
  • 17.Bich W., Cox M.G., Harris P. M., Evolution of the Guide to the Expression of Uncertainty in Measurement, Metrologia, 3, S161 (2006).
  • 18.Chambless D. A., Dubose S.S., Sensintaf Far E.L., Detection Limit Concepts: Foundations, Myths and Utilization, Health Phys., 63,338 (1992).
  • 19.Sommer K.D., Siebert B.R.L., Systematic Approach to the Modelling of Measurement for Uncertainty Evaluation, Metrologia, 43 S200, (2006).
  • 20.ISO GUM Supplement 1 Propagation of Distributions Using a Monte Carlo Method.
  • 21.Sivia D.S., Data Analysis-A Bayesian Tutorial, Oxford, Clarendon Press, 1996.
  • 22.Sterlinski S., Bober Z., Nazarov V.M., Results of the Determination of Selected Trace Elements in Oriental Tobacco Leaves Obtained by Instrumental Neutron Activation Analysis, Proc. Inter. Conf., Activation Analysis in Environmental Protection, Dubna, Russia, 1992, p. 369.
  • 23.Rogers V.C., Detection Limits for Gamma-Ray Spectra Analysis, Anal. Chem., 42, 807 ( 1970).