Measurement of concentrations levels of volatile organic compounds (VOC) such as benzene, toluene, butyl acetate, ethylbenzene, m-xylene, styrene and m-dichlorobenzene was carried out in three newly erected and remodelled dwellings in Tricity area. To col-lect the series of air samples the active and passive methods were used. In both cases acti-vated charcoal was applied as a sorption medium. The samples were liberated by solvent extraction, and analyzed by capillary column gas chromatography, employing a flame ionisation detector. The study also attempted to examine the time dependence of coricen-trations of selected VOC in each investigated dwelling. This was accomplished by at least triplicate measurements of the IAQ. The experimental results showed that values for analyzed VOC were exceeded (even a few orders of magnitude) for the measurements made before inhabiting of the occupants, in every investigated dwelling. The concentra-tions of the investigated VOC decreased significantly with time, which should be ex-pected, although in some cases the levels of selected VOC remained still high. Our experience indicates that application of two different indoor air sampling techniques to determine analytes of interest, though more laborious and time consuming, can lead to significant conclusions concerning indoor air quality.
Jakość powietrza wewnętrznego badano w trzech nowowybudowanych i wyremontowanych pomieszczeniach mieszkalnych położonych na terenie Trójmiasta. Oceny jakości powietrza dokonano na podstawie pomiarów poziomów stężeń wybranych lotnych związków organicznych, takich jak: benzen, toluen, octan butylu, etylobenzen, m-ksylen, styren i w-dichlorobenzen. Próbki powietrza pobierano wykorzystując dwie różne techniki izolacji i wzbogacania analitów z medium gazowego - technikę pasywną i technikę dynamiczną. Jako medium sorpcyjne, w obydwu przypadkach, stosowano węgiel aktywny. Analizy wykonywano za pomocą kapilarnej chromatografii gazowej. Celem przeprowadzonych badań było również określenie wpływu czasu eksploatacji mieszkań na poziom stężeń monitorowanych lotnych związków organicznych. Doko-nano tego na podstawie trzykrotnych pomiarów jakości powietrza wewnętrznego. Na podstawie otrzymanych wyników stwierdzono, że wyznaczone, w pomieszczeniach przed zasiedleniem, wartości stężeń badanych związków przekraczały (znacznie) wartości stężeń dopuszczalnych. Wyniki badań wykazują, że stosowanie dwóch technik pobierania próbek z powietrza wewnętrznego w celu oznaczenia analitów może stanowić podstawę do wysuwania pogłębionych wniosków co do jakości powietrza.
Czasopismo
Rocznik
Tom
Strony
11-26
Opis fizyczny
Bibliogr. 15 poz.
Twórcy
autor
- Technical University of Gdańsk, Chemical Faculty, Department of Analytical Chemistry, 80-952 Gdańsk, 11/12 Narutowicza Str., Poland
autor
- Technical University of Gdańsk, Chemical Faculty, Department of Analytical Chemistry, 80-952 Gdańsk, 11/12 Narutowicza Str., Poland
autor
- Science & Mathematics Department, Kettering University, 1700 West Third Avenue Flint, Michigan, USA
autor
- Technical University of Gdańsk, Chemical Faculty, Department of Analytical Chemistry, 80-952 Gdańsk, 11/12 Narutowicza Str., Poland, chemanal@pg.gda.pl
Bibliografia
- 1. Namieśnik J., Górecki T., Kozdroń-Zabiegała B. and Łukasiak J., Building and Environ., 27, 339 (1992).
- 2. Namieśnik J., Zygmunt B. and Kozdroń-Zabiegała B., Pol. J. Environ. Stud., 3, 5 (1994).
- 3. Cohen Y., ASTM STP, 1267, 7 (1997).
- 4. Otson R. and Fellin Ph., Volatile organics in the indoor environment: sources and occurrence, in: Gaseous Pollutants: Characterization and Cycling, [Nriagu J.O., Ed.], John Wiley & Sons, Inc., 1992, pp. 335-342.
- 5. Lagoudi A., Loizidou M. and Asimakopoulos D., Indoor Built Environ., 5, 348 (1996).
- 6. Lagoudi A., Loizidou M. and Asimakopoulos D., Indoor Built Environ., 5, 341 (1996).
- 7. European Concerted Action INDOOR AIR QUALITY & ITS IMPACT ON MEN, Environment and Quality of Life Report No. 6, Strategy for sampling chemical substances in indoor air, EUR 12617 EN, Luxembourg 1989.
- 8. Sheifert B., Sampling and analysis of ambient and indoor air, Chapter 9; in: Environmental Carcinogens Methods of Analysis and Exposure Measurement [L. Fishbein and I.K. O'Neill, Eds.], vol. 10, International Agency for Research on Cancer, Lyon 1988.
- 9. Kozdroń-Zabiegała B., Przyjazny A. and Namieśnik J., Indoor Built Environ., 5, 212 (1996).
- 10. European Concerted Action INDOOR AIR QUALITY & ITS IMPACT ON MEN, Environment and Quality of Life Report No. 10, Effects of indoor air pollution on human health, EU 14086 EN, Luxembourg 1991.
- 11. Kozdroń-Zabiegała B., Przyjazny A. and Namieśnik J., Indoor Built Environ., 4, 189 (1995).
- 12. Namieśnik J., Górecki T., Kozdroń-Zabiegała B. and Torres L., Intern. J. Environ. Anal. Chem., 37, 139 (1989).
- 13. Kozdroń-Zabiegała B., Namieśnik J. and Zygmunt B., Chem. Anal. (Warsaw), 41, 209 (1996).
- 14. Kozdroń-Zabiegała B., Przyk E., Zygmunt B. and Namieśnik J., Chem. Anal. (Warsaw), in print.
- 15. Regulation of the Minister of Health and Social Security of Poland from March 12, 1996 on maximum allowable concentrations of pollutants emitted by building materials and furnishings in inhabited closed areas. Monitor Polski Nr 19, poz 231.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0017-0002