EN
Surfaces of titanium samples were modified by methods which are commonly used with implants. The specimen-surfaces have been investigated by scanning electron microscopy (SEM), surface profiling and electrochemical impedance spectroscopy (EIS). The results of EIS correlate - for simple equivalent circuits - to results of surface-profile measurement. To interpret complex circuits in a meaningful manner, further systematic investigations will be necessary at pre-defined structures and layers.
Wydawca

Rocznik
Strony
215-218
Opis fizyczny
Bibliogr. 12 poz., rys.
Twórcy
autor
  • University of Rostock, German
autor
  • University of Rostock, German
  • University of Rostock
Bibliografia
  • [1] Stach. R.: Die Grenzfläche zwischen bioinerten lmplantntwerkstoffen und dem Knochen, Diss. RWTH Aachen 1996, Shaker Verlag
  • [2] Wirsching, J.: Kovalente Immobilisierung des Zelladhäsionsmediators Fibronectin an oberflächenfunktionalisiertes PVC-Copolymer für den Einsatz als medizinischen Implantatwerkstoff. Diss. RWTH Aachen 1997, Shaker Vcrlag
  • [3] Höcker, H.: Implantatwerkstoffe-Versuche zur Erzielung von Biokompatibilität. In : Vorträge/Nordrhein-Westfälische Akademie der Wisscnschaften: Natur-, Ingenieur- und Wirtschaftswissenschaften; N 430, Westdeutscher Verlag 1997
  • [4] Sauberlich, S.: ln-vitro-Untersuchungen zur Weichgewebnerträg lichkeit unterschiedlich modifizierter Titanoberflächen, Diss RWTH Aachen 1996, Shaker Vcrlag
  • [5] Orsini, G.; Assenza, B.; Scarano, A.; Piatelli, M , Piatelli, A : Surface analysis of machined versus sandblasted and acid-etched titanium implants, Int. J. Orał Maxillofac. Implants 2000 ( ov)
  • [6] Beck, U.; Schüll. H.J.: Influence of space charge on the corrosive behaviour of titanium oxide deduced from EIS. Corrosion Reviews, vol. 18 (2000)
  • [7] Pan, J.; Liao, H.; Leygraf, C.; Thierry, O.; Li, J.: Variation of oxide films on titanium induced by osteoblast-like cell culture and the influence ofd an H2O2 pretreatment, J. of Biomedical Materials Research, May 1998, Vol. 40, No. 2
  • [8] McDonald, R.: Impedance spectroscopy - emphasizing solid materials and systems, John Wiley & Sans, New York 1987
  • [9] de Levie, R.: Electrochemical Response of porous and rough Electrodes, In: Advances in electrochemistry and electrochemical engineering cd. by P. Delahay Vol.6, Intersciencc, New York, I 967
  • [10] Liu, S. H.: Fractal model for the ac response of a rough Interface In: Phys. Rev. Lett., Vol. 55 (1985), 5, S.529-532
  • [11] Bates, J. B.; Chu, Y. T.: Surface topography and electrical response of meral-electrolyte interfaces, In : Solid Statcs lonics J 988, 28-30, s. 1388-1395
  • [12] Rammelt, U.; Reinhard, G.: Einfluß von scheinbarer und inhärenter Frequenzdispersion auf das Impedanzspektrum einer Festelektrode In: Wiss. Zeitschr. der TU Dresden, 41 (1992), Hefl 5 S. 57-61
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BOS5-0001-0030
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.