EN
Competitive adsorption of the solute and the polar component of the mobile phase (the modifier) in reversed-phase liquid chromatography is discussed. Retention properties on surfaces differing in alkyl chain length (RP-18 compared with RP-8e) have been investigated. Typical solvent mixtures were used as mobile phases–methanol–water and acetonitrile–water. Three different types of compound were selected as solutes–two homologous cycloketones, cyclopentanone and cyclohexanone, and phenol. For all these solutes the adsorption mechanism was heterogeneous – the compounds had affinity for the polar uncovered surface and for the alkyl chains. Adsorption of organic solvents on the RP-8e (endcapped) adsorbent was measured and compared with that on RP-18e and RP-18 (non-endcapped) measured in previous studies. The adsorption equilibrium of solvents was strongly affected by the structure of the adsorbent surface and the polarity of the mobile phase. Variation of separation selectivity as a function of surface properties and mobile-phase composition was also investigated, and is discussed. The model of competitive adsorption proposed in our previous study has been used for analysis of the retention behaviour of the solutes and for prediction of non-linear chromatographic band profiles.
Słowa kluczowe
Wydawca

Rocznik
Tom
Strony
46-71
Opis fizyczny
Bibliogr. 35 poz., rys., tab.
Twórcy
autor
  • Department of Chemical and Process Engineering, Rzeszów University of Technology, 6 Powstańców Warszawy Ave., 35-959 Rzeszów, Poland
Bibliografia
  • [1] D.E. Martire and R.E. Boehm, J. Phys. Chem., 87, 1045 (1983)
  • [2] K.A. Dill, J. Phys. Chem., 91, 1980 (1987)
  • [3] P.T. Ying, J.G. Dorsey, and K.A. Dill, Anal. Chem., 61, 2540 (1989)
  • [4] M. Jaroniec and D.E. Martire, J. Chromatogr., A, 351, 1 (1986)
  • [5] J.H. Park, Y.K. Lee, Y.C. Weon, L.C. Tan, J. Li, L. Li, J.F. Evans, and P.W. Carr, J. Chromatogr. A, 767, 1 (1997)
  • [6] P.W. Carr, J. Li, A.J. Dallas, D.I. Eikens, and L.C. Tan, J. Chromatogr. A, 656, 113 (1993)
  • [7] H. Poppe, J. Chromatogr. A, 656, 19 (1993)
  • [8] A. Vailaya and C. Horvath, J. Chromatogr. A, 829, 1 (1998)
  • [9] L.R. Snyder, in: Cs. Horvath (Ed.) High Performance Liquid Chromatography – Advances and Perspectives, Vol. 1, Academic Press, New York, 1980, p. 207
  • [10] L.R. Snyder and M.A. Stadalius, in: Cs. Horvath (Ed.) High Performance Liquid Chromatography – Advances and Perspectives, Vol. 4, Academic Press, New York, 1986, p. 193
  • [11] A. Wang and P.W. Carr, J. Chromatogr. A, 965, 3 (2002)
  • [12] P.J. Schoenmakers, Optimization of Chromatographic Selectivity – A Guide to Method Development, Journal of Chromatography Library, Vol. 35, Elsevier, Amsterdam, 1986
  • [13] K. Kaczmarski, W. Prus, and T. Kowalska, J. Chromatogr. A, 869, 57 (2000)
  • [14] P. Nikitas, A. Pappa-Louisi, and P. Agrafiotou, J. Chromatogr. A, 946, 9 (2002)
  • [15] A. Felinger and G. Guiochon, J. Chromatogr. A, 796, 59 (1998)
  • [16] F. Gritti and G. Guiochon, J. Chromatogr. A, 1010, 153 (2003)
  • [17] F. Gritti, A. Fellinger, and G. Guiochon, J. Chromatogr. A, 1017, 45 (2003)
  • [18] P. Jandera, D. Komers, and G. Guiochon, J. Chromatogr. A, 796, 115 (1998)
  • [19] D. Antos, W. Piątkowski, and K. Kaczmarski, J. Chromatogr. A, 874, 1 (2000)
  • [20] I. Poplewska and D. Antos, Chem. Eng. Sci., 60, 1411 (2005)
  • [21] I. Poplewska, W. Piątkowski, and D. Antos, J. Chromatogr. A, 1103, 284 (2006)
  • [22] G. Guiochon, S. Golshan-Shirazi, and A.M. Katti, Fundamentals of Preparative and Nonlinear Chromatography, Academic Press, Boston, 1994
  • [23] G. Guiochon and B. Lin, Modelling for Preparative Chromatography, Academic Press, Amsterdam, 2003
  • [24] M.J. Ościk, Adsorption, Ellis Horwood, Chichester, 1982
  • [25] G. Schay in: E. Matijevic (Ed.) Surface and Colloid Science, Vol. 2, Wiley, London, 1969
  • [26] G. Schay in: D.H. Everett (Ed.) Surface Area Determination, Proc. Int. Symp., Butterworths, London, 1969
  • [27] S.J. Klatte and T.L. Beck, J. Phys. Chem., 100, 5931 (1996)
  • [28] D.M. Bliesner and K.B. Sentell, Anal. Chem., 65, 1819 (1993)
  • [29] W. Piątkowski, I. Petrushka, and D. Antos, J. Chromatogr. A, 1092, 65 (2005)
  • [30] J. Lindholm, P. Forssen, and T. Fornstedt, Anal. Chem., 76, 4856 (2004)
  • [31] J. Lindholm, P. Forssen, and T. Fornstedt, Anal. Chem., 76, 5472 (2004)
  • [32] H.K. Hansen, P. Rasmussen, and A. Fredebslund, Ind. Eng. Chem. Res., 30, 2352 (1991)
  • [33] J.H. Park, M.D. Jang, J.J. Chae, H.C. Kim, and J.K. Suh, J. Chromatogr. A, 656, 69 (1993)
  • [34] A.M. Stalcup, D.E. Martire, and S.A. Wise, J. Chromatogr., 42, 1 (1988)
  • [35] N.S. Wilson, M.D. Nelson, J.W. Dolan, L.R. Snyder, R.G. Wolcott, and P.W. Carr, J. Chromatogr. A, 961, 171 (2002)
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT8-0006-0040
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.