Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2007 | No. 18 | 249-259
Tytuł artykułu

Suitability of the Chromdes DS-L horizontal TLC chamber for temperature-controlled planar chromatography

Wybrane pełne teksty z tego czasopisma
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Isothermal thin-layer chromatography in a non-thermostatted horizontal chamber has been investigated at sub-ambient and elevated temperatures. The rate of temperature equilibration was determined for the commercially available Chromdes DS-L horizontal TLC chamber placed in a circulating-air incubator. The time required for temperature equilibration was also studied for commonly used glass and aluminium backed plates transferred from room temperature to a chamber at temperatures ranging from 5 to 40°C. The effect of temperature on the retention and separation the steroids cholesterol, ergosterol, and stigmasterol was also investigated. Practical aspects of system robustness, temperature distribution within the chromatographic chamber, the stability of plate temperature, and applications of the method are also discussed.
Słowa kluczowe
Wydawca

Rocznik
Tom
Strony
249-259
Opis fizyczny
Bibliogr. 26 poz., rys., tab.
Twórcy
autor
  • Laboratory of Toxicology, Department of Environmental Biology, Koszalin University of Technology, Śniadeckich 2, 75-453 Koszalin, Poland
Bibliografia
  • [1] F. Geiss, Fundamentals of Thin-Layer Chromatography (Planar Chromatography), Hüthig, Heidelberg, 1987
  • [2] J. Sherma and B. Fried, Handbook of Thin-Layer Chromatography. 3rd edn., Dekker, New York, 2003
  • [3] P.E. Wall, Thin-Layer Chromatography. A Modern Practical Approach, RSC, Cambridge, 2004
  • [4] T. Kowalska and J. Sherma, Preparative Layer Chromatography, Chromatographic Science Series, Vol. 95, CRC Press, Boca Raton, 2006
  • [5] Camag Automatic Developing Chamber ADC 2; Webpage address: http://www.camag.ch/v/products/development/adc2.html
  • [6] V.G. Berezkin, E.G. Sumina, S.N. Shtykov, V.Z. Atayan, D.A. Zagniboroda, and G.A. Nekhoroshev, Chromatographia, 64, 105 (2006)
  • [7] P.K. Zarzycki and H. Lamparczyk, Chem. Anal., 46, 469 (2001)
  • [8] T.H. Dzido, J. Planar Chromatogr., 6, 78 (1993)
  • [9] P.K. Zarzycki, J. Chromatogr. A, 971, 193 (2002)
  • [10] T.H. Dzido, Pol. Pat. Appl. No. 313053. Feb. (1996)
  • [11] Chromdes Horizontal DS Chambers for Thin-Layer Chromatography; Webpage address: http://chromdes.com/index.htm
  • [12] F. Geiss and H. Schlitt, J. Chromatogr., 33, 208 (1968)
  • [13] V.G. Berezkin and S.L. Bolotow, J. High Resolut. Chromatogr. Chromatogr. Commun., 4, 398 (1981)
  • [14] V.G. Berezkin and S.L. Bolotow, J. High Resolut. Chromatogr. Chromatogr. Commun., 6, 203 (1983)
  • [15] L. Kolarovic, H. Cousin, and H. Traitler, J. High Resolut. Chromatogr., Chromatogr. Commun., 8, 838 (1985)
  • [16] L. Kolarovic and H. Traitler, J. High Resolut. Chromatogr., Chromatogr. Commun., 8, 342 (1985)
  • [17] D.W. Armstrong and X.F. Yang., J. Chromatogr., 456, 440 (1988)
  • [18] A.O. Kuhn, M. Lederer, and M. Sinibaldi, J. Chromatogr., 469, 253 (1989)
  • [19] B.M. Van Liedekerke, A.P. De Leenheer, and B.M. De Spiegeleer, J. Chromatogr. Sci., 29, 49 (1991)
  • [20] A. Rivas-Nass and S. Müllner, J. Planar Chromatogr., 7, 278 (1994)
  • [21] P.K. Zarzycki, J. Planar Chromatogr., 14, 63 (2001)
  • [22] X.R. Zhao, Q. Lin, and P.C. Brookes, Soil Biol. Biochem., 37, 311 (2005)
  • [23] C. Mille-Lindblom, E. Von Wachenfeld, and L.J. Tranvik, J. Microbiol. Methods, 59, 253 (2004)
  • [24] P.K. Zarzycki, M. Wierzbowska, and H. Lamparczyk, J. Chromatogr. A, 857, 255 (1999)
  • [25] P.K. Zarzycki and R. Smith, J. Chromatogr., A, 912, 45 (2001)
  • [26] P.K. Zarzycki, M. Wierzbowska, and H. Lamparczyk, J. Chromatogr. A, 857, 255 (1999)
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-article-BAT8-0006-0036
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.