Czasopismo
2010
|
Vol. 18, no. 1 (78)
|
59--62
Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Warianty tytułu
System do pomiaru natężenia i dawki promieniowania UV do zastosowań w procesach sieciowania nadruków funkcjonalizujących tekstylia
Języki publikacji
Abstrakty
Processes of the latticing of polymer overprints functionalizing textiles in the presence of photoinitiators require using high-energy UV radiation sources. However, the values of radiation intensities and UV doses used should be controlled so that they are no greater than those required by the proper course of the latticing process, on account of the high degrading impact of UV radiation on the fibre structure. In this article a mathematical model of intensity and UV dose radiation measurement constructed on the basis of the analysis of the phenomenon and catalogue information given by the producers of the radiation source, the UV filter and the sensor. The model of UV intensity measurement was analyzed with regard to inaccuracy on the basis of the uncertainty theory; the relative uncertainty of the measurement obtained was of an order of 3%.
Procesy sieciowania polimerowych nadruków funkcjonalizujących tekstylia z wykorzystaniem fotoinicjatorów wymagają zastosowania wysokoenergetycznych źródeł z promieniowaniem UV. Jednakże wartości stosowanych natężeń promieniowania i dawek promieniowania UV powinny być kontrolowane tak, aby nie były większe niż wymaga tego poprawny przebieg procesu sieciowania ze względu na duże degradacyjne oddziaływanie promieniowania UV na strukturę włókna. W artykule przedstawiono model matematyczny pomiaru natężenia i dawki promieniowania UV skonstruowany na podstawie analizy zjawiska i informacji katalogowych podanych przez producentów: źródła promieniowania, filtra UV i sensora. Model pomiaru natężenia promieniowania UV poddano analizie niedokładności w oparciu o teorię niepewności uzyskując niepewność względną pomiaru rzędu 3%.
Czasopismo
Rocznik
Strony
59--62
Opis fizyczny
Bibliogr. 15 poz., fig., tab.
Twórcy
autor
- Department for the Automation of Textile Processes, Technical University of Lodz, ul. Zeromskiego 116, 90-924 Lodz, Poland , stemp@p.lodz.pl
autor
- Department for the Automation of Textile Processes, Technical University of Lodz, ul. Zeromskiego 116, 90-924 Lodz, Poland , emagda@p.lodz.pl
autor
- Department for the Automation of Textile Processes, Technical University of Lodz, ul. Zeromskiego 116, 90-924 Lodz, Poland , kgniotek@p.lodz.pl
Bibliografia
- 1. Caputo D., de Cesare G., Nascetti A., Tucci M.: ‘Innovative Window Layer for Amorphous Silicon/Amorphous Silicon Carbide UV Sensor’, Journal of NonCrystalline Solids, 2006, Vol. 352, pp. 1818-1821.
- 2. Huang J., Ding H., Dodson W.S., Li Y.: ‘Application of TiO2 Sol for UV Radiation Measurements’, Analytica Chimica Acta, 1995, Vol. 311, pp. 115-122.
- 3. Liu S., Li P., Lan W.H., Lin W.: ‘Improvements of AlGaN/GaN p-i-n UV Sensors with Graded AlGaN Layer for the UV-B (280-320nm) Detection’, Materials Science and Engineering B, 2005, Vol. 122, pp. 196-200.
- 4. Lee J., Moon K., Ham M., Myoung J.: ‘Dielectrophoretic Assembly of GaN Nanowires for UV Sensor Applications’, Solid State Communications, 2008, Vol. 148, pp. 194-198.
- 5. Larason T.C., Cromer C.L.: ‘Sources of Error in UV Radiation Measurements’, J. Res. Natl. Inst. Stand. Technol., 2001, Vol. 106, pp. 649-656.
- 6. Homeck G.: ‘Quantification of the Biological Effectiveness of Environmental UV Radiation’, J. Photochem. Photobiol. B: Biol., 1995, Vol. 31, pp. 43-49.
- 7. Rettberg P., Horneck G.: ‘Biologically Weighted Measurement of UV Radiation in Space and on Earth with the Biofilm Technique’, Adv. Space Res., 2000, Vol. 26, No 12, pp. 2005-2014.
- 8. Park S., An B., Ha C.: ‘High-quality, Oriented and Mesostructured Organosilica Monolith as a Potential UV Sensor’, Microporous and Mesoporous Materials, 2008, Vol. 111, pp. 367-378.
- 9. Sommer R., Cabaj A., Sandu T., Lhotsky M.: ‘Measurement of UV Radiation Using Suspensions of Microorganisms’, J. Photochem. Photobiol. B: Biol., 1999, Vol. 53.
- 10. Ock K., Jo N., Kim J., Kim S., Koh K.: ‘Thin Film Optical Waveguide Type UV Sensor Using a Photochromic Molecular Device, Spirooxazine’, Synthetic Metals, 2001, Vol. 117, pp. 131-133.
- 11. Guide to the Expression of Uncertainty in Measurement, ISO 1995.
- 12. Dieck R.H.: ‘Measurement Uncertainty Methods and Applications’, Instrumentation Systems and Automation Society (ISA), United States 1997.
- 13. Technical note of a high pressure lamp of the HOK 20/100 type of Philips manufacture.
- 14. Technical note of a UV filter of NDQ- 250-0.5 type of CVI Melles Griot BV manufacture.
- 15. Technical note of a sensor of SG01S-HT type of sglux manufacture.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-88ab266c-6960-4ba5-8ba4-868c158ac919