Tytuł artykułu

CFD modelling of air flow and transport of contaminants in a passive house

Wybrane pełne teksty z tego czasopisma
Warianty tytułu
PL
Modelowanie metodą CFD (komputerowej dynamiki płynów) przepływu powietrza i transportu zanieczyszczeń w domu pasywnym
Języki publikacji
EN
Abstrakty
EN
Rising costs of energy have caused the building envelope in the living sector to become tighter to improve energy efficiency. This raises questions about the quality of the indoor air as in traditional housing fresh air is supplied not only by ventilation system by also by infiltration through cracks in the building envelope. If a building is not properly ventilated, contaminants could accumulate within it and their levels could become hazardous to human comfort and health.
PL
Wzrastające koszty energii spowodowały, że przegrody zewnętrzne w budynkach stały się coraz bardziej szczelne, aby polepszyć efektywność energetyczną. Rozpoczęło to szereg dyskusji na temat jakości powietrza w pomieszczeniach, ponieważ w tradycyjnym budownictwie świeże powietrze jest dostarczane poprzez infiltrację przez nieszczelności w budynku. Jeśli budynek nie jest odpowiednio wentylowany, zanieczyszczenia gromadzą się w nim, co może tworzy niekomfortowe warunki, które mogą niebezpieczne dla zdrowia.
Wydawca

Rocznik
Strony
443--453
Opis fizyczny
Bibliogr. 15 poz., tab., il., wykr.
Twórcy
  • Institute of Thermal Engineering and Air Protection, Faculty of Environmental Engineering, Cracow University of Technology
  • Institute of Thermal Engineering and Air Protection, Faculty of Environmental Engineering, Cracow University of Technology
Bibliografia
  • [1] Persily A.K., A modelling Study of Ventilation, IAQ and Energy Impacts of residential Mechanical Ventitalion, NIST, 1998.
  • [2] Pełech A., Wentylacja i klimatyzacja, Wydanie III, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 2010, 16-18.
  • [3] Jones A.P., Indoor air quality and health, School of environmental Sciences, University of East Anglia, 18 May 1998, 12-13, 323.
  • [4] Flaga-Maryanczyk A., Schnotale J., Radon J., Was K., Experimental measurements and CFD simulation of a ground sourceheat exchanger operating at a cold climate for a passive house ventilation system, Energy and Buildings 68, 2014, 562-570.
  • [5] Walton G.N., CONTAM User Guide and Program Documentation, Naval Surface Warfare Center, October 2005.
  • [6] Walton G.N., AIRNET – A Computer Program for Building Airflow Network Modeling, U.S. DEPARTMENT OF COMMERCE National Institute of Standards and Technology Gaithersburg, MD 20899, April 1989.
  • [7] Järnström H., Saarela K., Kalliokoski P., Pasanen A.-L., Reference values for indoor air pollutant concentrations in new residential buildings in Finland, Environment national, 2006.
  • [8] Christian J.E., Moisture Control in buildings, American Society for Testing and Materials, 1994, 176-178.
  • [9] Radoń J., Sprawozdanie z wykonania badań w domu pasywnym w ramach projektu „dom pasywny dla każdego – badania i rozwój przedsiębiorstwa Multicomfort”, ETAP I, 2011, 3-7.
  • [10] Justo Alonso M., Malvik B., Mathisen H.M., Haugen E.N., Energy Efficiency and Indoor Climate: Modelling Of Ventilation Systems Using ContamW (Ii), Icr 2011, August 21–26, Prague, Czech Republic.
  • [11] Szczepanik N., ContamW as a Tool for Modelling Indoor Air Quality for Assorted Ventilation Systems in a Passive House, Masters Theses, Kraków 2013.
  • [12] PN-83 B-03430 Az3 2000, Wentylacja w budynkach mieszkalnych i zamieszkania zbiorowego i użyteczności publicznej.
  • [13] www.epa.gov/iaq/co.html ‒ 26.03.2013.
  • [14] http://extension.oregonstate.edu/catalog/pdf/ec/ec1437.pdf ‒ 20.06.2013.
  • [15] http://www.euro.who.int/__data/assets/pdf_file/0017/43325/E92645.pdf, 89-92 ‒ 20.06.2013.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.baztech-828ccd73-44aa-4fce-9c5d-892836c7cba7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.