Hot water distribution system processes analysis proved that HW flow speed in tubes at normal operational regime at dwelling buildings (liquid flow speed 0.1 up to 0.5 m/s) has a minimal effect to the overall heat flow rate through pipe wall. Thermal resistance Rsi at heat transfer by flowing (convection) from the liquid to the pipe internal side is possible to neglect at heat flow rate calculation at hot water distribution systems in residential buildings for purposes, where pipes dimensions are from DN 15 mm to DM 32 mm.
Słowa kluczowe
Rocznik
Tom
Strony
136--142
Opis fizyczny
Bibliogr. 2 poz., tab., wykr.
Twórcy
autor
- Technicka univerzita v Kosiciach, Slovakia, peter.kapalo@tuke.sk
Bibliografia
- 1.Recknagel H., Sprenger E., Schramek E.R., Taschenbuch fur Heizung und Klimatechnik, Munchen, R. Oldenbourg Verlag GmbH, 1995.
- 2.Pavelek M. a kolektiv , Termomechanika, VUT Brno, CERM Brno, 2003.