Characteristics of selected fireproof properties of pa rticleboard made from particles impregnated with salt agent

Warianty tytułu
PL
Charakterystyka wybranych właściwości ogniochronnych płyty wiórowej z wiórów impregnowanych preparatem solnym
Języki publikacji
EN
Abstrakty
EN
Characteristics of selected fireproof properties of particleboard made from particles impregnated with salt agent. This paper presents results of selected fireproof properties of three-layer particleboard made from pine particles impregnated with open for general use bio- and salt fireproof agent for wood protection, based on quaternary ammonium compounds and boric acid. It leads to conclusion that impregnation of particleboards increases the fire resistance in relation to unprotected materials.
PL
Charakterystyka wybranych właściwości ogniochronnych płyty wiórowej z wiórów impregnowanych preparatem solnym. W pracy przedstawiono wyniki badań wybranych właściwości ogniochronnych płyt wiórowych trójwarstwowych wytworzonych z sosnowych wiórów drzewnych impregnowanych ogólnodostępnym bio- i ogniochronnym środkiem solnym do zabezpieczania drewna, na bazie czwartorzędowych związków amoniowych i kwasu borowego. W podsumowaniu stwierdzono, że przeprowadzona impregnacja zwiększa ognioodporność płyt wiórowych względem tworzyw niezabezpieczonych.
Słowa kluczowe
Wydawca
-
Rocznik
Tom
73
Opis fizyczny
p.142-146,fig.,ref.
Twórcy
  • Faculty of Wood Technology, Warsaw University of Life Sciences-SGGW, 159 Nowoursynowska St., 02-776 Warsaw, Poland
autor
  • Faculty of Wood Technology, Warsaw University of Life Sciences-SGGW, 159 Nowoursynowska St., 02-776 Warsaw, Poland
  • Department of Combustion and Fire Theory, Main School of Fire Service, 52/54 Slowackiego St., 01-629 Warsaw, Poland
autor
  • Faculty of Wood Technology, Warsaw University of Life Sciences-SGGW, 159 Nowoursynowska St., 02-776 Warsaw, Poland
autor
  • Faculty of Wood Technology, Warsaw University of Life Sciences-SGGW, 159 Nowoursynowska St., 02-776 Warsaw, Poland
  • Faculty of Wood Technology, Warsaw University of Life Sciences-SGGW, 159 Nowoursynowska St., 02-776 Warsaw, Poland
Bibliografia
  • 1. BABRAUSKAS V. 2005: Charring rate of wood as a tool for fire investigations. Fire Safety Journal 40 (2005) 528–554
  • 2. DRYSDALE D. 2001: Introduction to Fire Dynamics, J.Willey & Sons Inc.
  • 3. GREXA O., POUTCH F., MANIKOVA D., MARTVONOVA H., BARTEKOVA A. 2003: Intumescence in fire retardancy of lignocellulosic panels. Polymer Degradation and Stability 82 (2003) 373–377
  • 4. KOZŁOWSKI R., MIELENIAK B., HELWIG M., PRZEPIERA A. 1999: Flame resistant lignocellulosic-mineral composite particleboards. Polymer Degradation and Stability 64 (1999) 523-528
  • 5. OSIPIUK J. 2001: Trwałość zabezpieczenia drewna solnymi środkami ogniochronnymi. Wydawnictwo SGGW
  • 6. PN-EN ISO 11925-2: 2004 „Badanie reakcji na ogień. Zapalność materiałów poddanych bezpośredniemu działaniu płomienia. Część 2: Badanie przy działaniu pojedynczego płomienia” (“Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single-flame source test”)
  • 7. PN-EN ISO 4589-2: 1998 „Oznaczenie zapalności tworzyw sztucznych metodą wskaźnika tlenowego” (“Plastics - Determination of burning behaviour by oxygen index”)
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-ff750bc6-1348-4eff-b200-1f1bd498e80b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.