Czasopismo
Tytuł artykułu
Warianty tytułu
Zastosowanie cytometru przeplywowego do diagnostyki molekularnej Bacillus anthracis
Języki publikacji
Abstrakty
Flow cytometry is a method of identification biological agents that has various applications. It has been applied for identifying many types of antigens in various materials, including environmental samples. Recently it has been noticed that this method could be used for molecular detection of biological agents. The purpose of this work was to apply flow cytometry with nested-PCR for the molecular identification of B. anthracis. Paramagnetic streptavidin-coated beads were used to capture the resulting fluorophore-labeled sequences. The results show that flow cytometry can be successfully used to detect specific fluorescein- dUTP and a biotin marked sequences.
Cytometria przepływowa jest metodą identyfikacji czynników biologicznych o wielu zastosowaniach. Używano ją do wykrywania różnego rodzaju antygenów w różnych typach próbek także środowiskowych. Ostatnio metody cytometryczne zaczęto stosować w diagnostyce molekularnej czynników biologicznych. Celem tej pracy było zastosowanie metody cytometrii przepływowej i zagnieżdżonej reakcji łańcuchowej polimerazy DNA (nested -PCR) w diagnostyce molekularnej Bacillus anthracis. Użyto paramagnetyczne mikrokulki opłaszczone streptawidyną na których immobilizowany był wyznakowany fluorochromami produkt PCR. Wyniki wykazały, że metoda cytometrii przypływowej może służyć do wykrywania specyficznych sekwencji wyznakowanych fluoresceinąi biotyną.
Wydawca
Czasopismo
Rocznik
Tom
Numer
Opis fizyczny
p.1417-1423,fig.,ref.
Twórcy
autor
- Military Institute of Hygiene and Epidemiology, Lubelska 2 St., 24-100 Pulawy, Poland
autor
autor
autor
Bibliografia
- 1. Álvarez-Barrientos, A., Arroyo J., Cantón R., Nombela C., Sánchez-Peréz M.: Applications of Flow Cytometry to Clinical Microbiology; Clin. Microbiol. Rev. 2000; 13, 167.
- 2. Beyer W., Glockner P., Otto J., Bohm, R.; A nested PCR method for the detection of Bacillus anthracis in environmental samples collected from former tannery sites; Microbiol. Res. 1995; 150, 179.
- 3. Departament of Energy; Chemical-Biological Non-Proliferation Program (CBNP); Annual Report; USA, 2000.
- 4. Matras J., Mizak L; Diagnostyka Bacillus anthracis; Mikrobiologia i Medycyna. 1999; 3, 14.
- 5. Mock, M., Fouet A.; Anthrax; Ann. Rev. Microbiol. 2001; 55, 647.
- 6. Porter J., Pickup R., Edwards C.; Flow cytometric detection of specific genes in genetically modified bacteria using in situ polymerase chain reaction; FEMS Microbiol. Lett. 1995; 134, 51.
- 7. Schraft H., Griffiths M. W.; Specific oligonucleotide primers for the detection of lecithinase-positive Bacillus ssp. by PCR; Appl. Environ. Microbiol. 1995; 61, 98.
- 8. Stopa J. P.; The application of flow cytometry for the detection and identification of microbiological agent; PhD Thesis; Military Institute of Hygiene and Epidemiology, Warsaw – 1999.
- 9. Wedemeyer N., Potter T.; Flow cytometry: an ‘old’ tool for novel application medical genetics; Clin. Genet. 2001; 60, 1.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-article-a7338638-7a70-4ff0-8c0c-14b0870ebe88