Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
2008 | 23 | 4 | 837-849
Tytuł artykułu

The influence of solid magnetic field [SMF] on pseudo-Fenton's reaction of efficiency im meat industry sewages treatment

Warianty tytułu
PL
Wplyw stalego pola magnetycznego na efektywnosc reakcji pseudo-Fentona w procesie oczyszczania sciekow z przemyslu miesnego
Języki publikacji
EN
Abstrakty
EN
The possibility of solid magnetic field (SMF) used as a catalysator of radical process in pseudo- -Fenton’s (Fe³⁺/H₂O₂) reaction was invesigated in this experiment. Physical factor influence was qualified indirectly on the technological effect basis of received of reduce of COD value in sewages coming from the meat industry. The research was divided into three stages on laboratory scale. The influence of Fe³⁺/H₂O₂ was defined in first stage, whereas the influence of SMF was qualified in the second stage. The effect of simultaneous use of the advanced oxydation process (AOPs) and SMF in carbon substances degradation was researched in the third part of the experiment. The physical factor was generated by the magnetic heaps, located in magnetic liquids activator (MLA). SMF intensity applied in the experiment, comprised in levels of 0.4–0.6 T.It was affirmed that the SMF use as a helping element of AOPs allowed to get higher technological effect in the range of all tested doses of pseudo-Fenton’s reagent.
PL
W eksperymencie przebadano możliwość wykorzystania stałego pola magnetycznego (SPM) jako katalizatora procesu rodnikowania w reakcji pseudo-Fentona (Fe³⁺/H₂O₂). Wpływ czynnika fizycznego określono na podstawie uzyskanego efektu redukcji wartości ChZT w ściekach pochodzących z zakładu przemysłowego z branży mięsnej. Badania w skali laboratoryjnej podzielono na trzy etapy. W pierwszym etapie określono wpływ reagentów chemicznych Fe³⁺/H₂O₂, w drugim – SPM. W trzeciej części eksperymentu analizowano efekt jednoczesnego wykorzystania procesu pogłębionego utleniania (AOP) oraz SPM w procesie degradacji substancji węglowych. Czynnik fizyczny generowany był przez stosy magnetyczne magnetycznego aktywatora płynów (MAP). Natężenie SPM mieściło się w granicach 0,4-0,6 T. Stwierdzono, że zastosowanie SPM jako elementu wspomagającego AOP pozwoliło uzyskać wyższy efekt technologiczny w zakresie wszystkich testowych dawek odczynnika pseudo-Fentona.
Słowa kluczowe
Wydawca
-
Rocznik
Tom
23
Numer
4
Strony
837-849
Opis fizyczny
p.837-849,fig.,ref.
Twórcy
autor
  • University of Warmia and Mazury in Olsztyn, Romana Prawochenskiego 1-32, 10-957 Olsztyn, Poland
autor
autor
Bibliografia
  • ACERO J.L., BENITEZ F.J., REAL F.J., LEAL A.I. 2001. Degradation of p-hydroxyphenylacetic acid photo assisted Fenton reaction. Wat. Sci. Tech., 44(5): 31–38.
  • ARIENZO M., CHIARENZELLI J., SCRUDATO R., PAGANO J., FALANGA L., CONNOR B. 2001. Iron-mediated reactions of polychlorinated biphenyls in electrochemical peroxidation process (ECP). Chemosphere, 44(6): 1339–1346.
  • BAKER J.S., JUDD S.J. 1996. Magnetic amelioration of scale formation. Wat. Res., 30(2): 247–260.
  • BALCIOGLU I.A., ARSLAN J. 2001. Partial oxidation of reactive dyestuffs and synthetic textile dye-bath by the O₃ and O₃/H₂O₂ processes. Wat. Sci. Tech., 43(2): 221–228.
  • BRILLAS E., CALPE J.C., CASADO J. 2000. Mineralization of 2,4-D by advanced electrochemical oxidation processes. Wat. Res., 34(8): 2253–2262.
  • CHOU S., HUANG Y.H., LEE S.N., HUANG G.H., HUANG C. 1999. Treatment of high strength hexamine-containing wastewater by electro-Fenton method. Wat. Res., 33(3): 751–759.
  • CHUDZIK B. 1997. Oczyszczanie ścieków z małych rzeźni i mleczarni. Ekoinżynieria, 2: 14–21.
  • CONTRERAS S., RODRIQUEZ M., CHAMARRO E., ESPLUGAS S., CASADO J. 2001. Oxidation of nitrobenzene by O₃/UV: the influence of H₂O₂ and Fe (III). Experiences in a pilot plant. Wat. Sci. Tech., 44(5): 39–46.
  • ENGWALL M.A., PIGNATELLO J.J., GRASSO D. 1999. Degradation and detoxification of the wood preservatives creosote and pentachlorophenol in water by the photo-Fenton reaction. Wat. Res., 33(5): 1151–1158.
  • HUANG P.C., CHENGDI D., TANG Z. 1993. Advanced chemical oxidation: its present role and potential future in hazardous waste treatment. Waste Management, 13: 361–369.
  • HUANG Y.H., CHOU S., PERNG M.G., HUANG G.H., CHENG S.S. 1999. Case study on the bioeffluent of petrochemical wastewater by electro-Fenton method. Wat. Sci. Tech., 39(10–11): 145–149.
  • INCE N.H., TEZCANLI G. 1999. Treatability of textile dye-bath effluents by advanced oxidation: preparation for reuse. Wat. Sci. Technol., 40(1): 183–190.
  • JAJTE J., GRZEGORCZYK J., ZMYŚLONY M., RAJKOWSKA E. 2002. Effect of 7 mT static magnetic field and iron ions on rat lymphocytes: apoptosis, necrosis and free radical processes. Bioelectrochemistry, 57: 107–111.
  • KRZEMIENIEWSKI M., DĘBOWSKI M., DOBRZYŃSKA A., ZIELIŃSKI M. 2004. Chemical oxygen demand reduction of various wastewater types using magnetic field - assisted Fenton reaction. Wat. Env. Res., 76(4): 301–305.
  • KRZEMIENIEWSKI M., DĘBOWSKI M., JANCZUKOWICZ W., PESTA J. 2003. Effect of sludge conditioning by chemical methods with magnetic field application. Pol. J. Environ. Stud., 12 (5): 595–605.
  • KRZEMIENIEWSKI M., DOBRZYŃSKA A., JANCZUKOWICZ W., PESTA J., ZIELIŃSKI M. 2002. Wpływ stałego pola magnetycznego na proces generowania rodników hydroksylowych. Chemik, 1: 12–15.
  • KRZEMIENIEWSKI M., ZIELIŃSKI M., BEDNARSKI W., PŁODZIEŃ T. 2000. Badanie skuteczności podczyszczania ścieków mleczarskich metodą pogłębionego utleniania. Prz. Mlecz., 11: 266–369.
  • LU M.CH., ROAM G.D., CHEN J.N., HUANG C.P. 1994. Photocatalytic oxidation of dichlorvos in the presence of hydrogen peroxide and ferrous ion. Wat. Sci. Technol., 30(9): 29–38.
  • MARTI C.A., ALFANO O.M., CASSANO A.E. 2001. Water decolorization using UV radiation and hydrogen peroxide: a kinectic study. Wat. Sci. Tech., 44( 5): 53–60.
  • MCGINNIS B.D., ADAMS V.D., MIDDLEBROOKS E.J. 2000. Degradation of ethylene glycol in photo-Fenton system. Wat. Res., 34(8): 2346–2354.
  • MCLAUCHLAN K.A., STEINER U.E. 1991. The spin correlated radical pair as a reaction intermediate. Mol. Phys., 73: 241–263.
  • MURPHY A.P., BOEGLI E.J., PRICE M.K., MOODY C.D. 1989. A Fenton-like reaction to neutralize formaldehyde waste solutions. Environ. Sci. Technol., 23: 166–169.
  • PIGNATELLO J.J., SUN Y. 1995. Complete oxidation of metolachlor and methyl parathion in water by the photoassisted Fenton reaction. Wat. Res., 29(8): 1837–1844.
  • SIGGE G.O., BRITZ T.J., FOURIE P.C., BARNARDT C.A., STRYDOM R. 2001. Use of ozone and hydrogen peroxide in the post. – tretment of UASB treated alcaline fruit cannery effluent. Wat. Sci. Tech., 44(5): 69–74.
  • SUN Y., PIGNATELLO J.J. 1993. Photochemical reactions involved in the total mineralization of 2,4 – D by Fe³⁺/H₂O₂/UV. Environ. Sci. Technol., 27: 304–313.
  • XU Y. 2001. Comparative studies of the Fe³⁺/²⁺ – UV, H₂O₂ – UV, TiO₂-UV/vis systems for the decolorization of a textile dye X-3B in water. Chemosphere, 43(8): 1103–1107.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-article-1833a3f0-c763-4920-9f14-f151bd0eb9b6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.