Czasopismo
Tytuł artykułu
Warianty tytułu
Języki publikacji
Abstrakty
Near infrared spectroscopy (NIRS) is increasingly used as a local tissue oxygenation equipment and it fulfills the functions of an efficient local microcirculation and a concussion growth monitor. Using it in surgery, physiotherapy or rescue indicates a high interdisciplinary diagnostic potential, which could lead us to improve the quality of patients’ lives. The aim of this study was to review literature related to the physiotherapy aspect of using near infrared spectroscopy and to the consideration given to the development of this method. A review of literature related to the topic. Research shows that NIRS is a good tool to assess the changing state of microcirculation in the monitored area. As mentioned above, NIRS can be used in a number of methods available in traditional medicine and physiotherapy. This work is only a set of selected methods, but the development of technology can help to minimize the dimensions of such devices, and to maximize the effects and use of this method, which will certainly make the healing process easier.
Słowa kluczowe
Wydawca
Rocznik
Tom
Numer
Opis fizyczny
p.141-150,fig.,ref.
Twórcy
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
autor
- Department of Physiology, Gdansk University of Physical Education and Sport in Gdansk, Gdansk, Poland
Bibliografia
- [1] Jöbsis FE. Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science. 1977;198:1264–7.
- [2] Atknis PW. Chemia fizyczna [Physical chemistry]. Warszawa: Wydawnictwo Naukowe PWN; 2001. Polish.
- [3] Maniewski R, Liebert A. Metoda laserowo-dopplerowska w badaniach mikrokrążenia krwi [The laser-Doppler method in testing blood microcirculation]. Warszawa: Exit; 2003. Polish.
- [4] Liebert A, Witkowski K, Mayzner-Zawadzka E. Application of multichannel laser-doppler flowmeter in anaesthetic measurements. Eng Med Biol Soc. 1995;b:484–5.
- [5] Kęcki Z. Podstawy spektroskopii molekularnej [Basics of molecular spectroscopy]. Warszawa: PWN; 1998. Polish.
- [6] Sundberg S, Castrén M. Drug- and temperature-induced changes in peripheral circulation measured by laser-doppler flowmetry and digital-pulse plethysmography. J Clin Lab Invest. 1986 Jun;46(4):359–65.
- [7] Skoczylas A, Śliwiński P. Pletyzmografia optoelektroniczna – nowa technika pomiaru zmian objętości klatki piersiowej [Optoelectronic plethysmography – a new technique of measuring changes in the chest volume]. Pneumonol Alergol Pol. 2007;75:81–7. Polish.
- [8] Shinozaki T, Deane R, Perkins FM. Infrared tympanic thermometer: Evaluation of a new clinical thermometer. Crit Care Med. 1988;16:148–50.
- [9] Gush R. Investigation and improved performance of optical fibre probes in laser doppler blood flow measurement. Med Biol Eng Comput. 1987;25:391–6.
- [10] Johansson K. Assessment of intestinal ischemia. In: Belcaro G, editor. Laser-doppler London: Med.-Orion; 1994, 189–200.
- [11] Witkowski K., Mayzner-Zawadzka E. Clinical assessment of microvascular perfusion in regional anaesthesia. In: ICB seminar Optoelectronics in Medical Diagnosis. 1997, 79–82.
- [12] DeLorey DS, Kowalchuk JM, Heenan AP, Dumanoir GR, Paterson DH. Prior exercise speeds pulmonary O2 uptake kinetics by increases in both local muscle O2 availability and O2 utilization. J Appl Physiol. 2007;103(3):771–8.
- [13] Speed CA. Therapeutic ultrasound in soft tissue lesions. Rheumatology. 2001;40:1331–36.
- [14] Wong AR, Schumann B, Townsend R, Phelps CA. A survey of therapeutic ultrasound use by physical therapists who are orthopedic certified specialists. Phys Ther. 2007;87(8):986–994.
- [15] Morishita K, Karasuno H, Yokoi Y, et al. Effects of therapeutic ultrasound on intramuscular blood circulation and oxygen dynamics. J Jpn Phys Ther Assoc. 2014:17(1):1–7.
- [16] Durkin JL, Harvey A, Hughson RL, Callaghan JP. The effects of lumbar massage on muscle fatigue, muscle oxygenation, low back discomfort, and driver performance during prolonged driving. Ergonomics. 2006 Jan 15;49(1):28–44.
- [17] Munk N, Symons B, Shang Y, Cheng R, Yu G. Noninvasively measuring the hemodynamic effects of massage on skeletal muscle: A novel hybrid near-infrared diffuse optical instrument. J Bodyw Mov Ther. 2012 Jan;16(1):22–28.
- [18] Lee S, Kim TH, Youn JI. Development of the theragnostic optical system for a high-intensity laser therapy (HILT). Lasers Med Sci. 2014 Sep;29(5):1585–91.
- [19] Litscher G. Bioengineering assessment of acupuncture – part 2: monitoring of microcirculation. Crit Rev Biomed Eng. 2006; 34(4):273–294
- [20] Hsiu H, Hsu WC, Chang SL, Hsu CL, Huang SM, Lin YYW. Microcirculatory effect of different skin contacting pressures around the blood pressure. Physiological Measurement. 2008;29(12):1421–1434.
- [21] Hsiu H, Hsu WC, Chen BH, Hsu CL. Differences in the microcirculatory effects of local skin surface contact pressure stimulation between acupoints and nonacupoints: possible relevance to acupressure. Physiological Measurement. 2010;31(6):829–841.
- [22] Litscher G, Ofner M, He W, Wang L, Gaischek I. Acupressure at the meridian acupoint Xiyangguan (GB33) influences near-infrared spectroscopic parameters (regional oxygen saturation) in deeper tissue of the knee in healthy volunteer. Evid Based Complement Alternat Med. 2013;370341.
- [23] Meng CR, Fan L, Fu WB, Li Y. Clinical research on abdominal acupuncture plus conventional acupuncture for knee osteoarthritis. J Trad Chin Med. 2009;29(4):249–252.
- [24] Litscher G. Integrative laser medicine and high-tech acupuncture at the Medical University of Graz, Austria, Europe. Evid Based Complement Alternat Med. 2012;21:103–109.
- [25] Shadgan B, Med S, Pakravan AH, Hoens A, Reid WD. Subcutaneous and intramuscular hemodynamics and oxygenation after cold-spray application as monitored by near-infrared spectroscopy. J Athl Train. 2015 Aug;50(8):800–5.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-5dc66fc2-9d04-468f-a268-a4f6418d6a85