Warianty tytułu
Języki publikacji
Abstrakty
Disinfection of anaerobically treated municipal wastewater was done using ozone, UV, H2O2, peracetic acid, and advanced oxidation processes (O3/H2O2, O3/UV, H2O2/UV, H2O2/sunlight). Ozone, UV irradiation, and H2O2 eliminated 99% of pathogens (total coliform, fecal coliform, and E. coli) at ozonation time of 20 min at the rate of 1000 mg/hr; UV irradiation time of 11 min and H2O2 dose of 336 mg/L. The use of combined systems (H2O2/sunlight) is especially promising due to the synergistic effect and cost efffectiveness. Regrowth of pathogens increased with increase in time and temperature (from 15 to 35ºC). The presence of nutrients and fluorescent light enhanced the rate of reactivation of pathogens.
Wydawca
Czasopismo
Rocznik
Tom
Numer
Opis fizyczny
p.1153-1161,fig.,ref.
Twórcy
autor
- Environmental Sciences Department, Government College University, Faisalabad, Pakistan
autor
- Institute of Geology, University of the Punjab, Lahore, Pakistan
autor
- Sustainable Development Study Center, Government College University, Lahore, Pakistan
autor
- Institute of Geology, University of the Punjab, Lahore, Pakistan
autor
- Institute of Geology, University of the Punjab, Lahore, Pakistan
Bibliografia
- 1. CHERNICHARO C. A. L. Post-treatment options for the anaerobic treatment of domestic wastewater. Rev Environ Sci. Biotechnol. 5, 73, 2006.
- 2. BLATCHLEY E. R., DUMOUTIER N., HALABY T. N, LEVI Y., LAINE J. M. Bacteria responses to ultraviolet irradiation. Water Sci. Technol. 43, 179, 2001.
- 3. YASAR A., NASIR A., HUMMAIRA L., AAMIR A. A. K. Regrowth in UASB effluent disinfected by UV, O3, H2O2 and advanced oxidation processes. Ozone Sci. Engin. 29, 485, 2007.
- 4. WANG X., HU X., HU C., WEI D. Sequential use of ultraviolet light and chlorine for reclaimed water disinfection. J. Environ. Sci. (China). 23, (10), 1605, 2011.
- 5. LOEB B. L., THOMPSON C. M., DRAO J., TAKAHARA H., SYLVIE B. Worldwide Ozone capacity for treatment of drinking water and wastewater: A review. Ozone Sci. Engin. 34, (1), 64, 2012.
- 6. ZHOU H., SMITH D. W. Advanced technologies in water and wastewater treatment. J Environ Eng Sci. 1, 247, 2002.
- 7. YASAR A., AHMAD N., CHAUDHRY M. N., REHMAN M. S. U., KHAN A. A. A. Ozone for Color and COD Removal of Raw and Anaerobically Biotreated Combined Industrial Wastewater. Pol. J. Environ. Stud. 16, (2), 289, 2007.
- 8. COMNINELLIS C., KAPALKA A., MALATO S., PARSONS S. A., POULIOS I., MANTZAVINOS D. Advanced oxidation processes for water treatment: advances and trends for R&D. J. Chem. Technol. Biot. 83, 769, 2008.
- 9. DE LA CRUZ N., GIMENEZ J., ESPLUGAS S., GRANDJEAN D., DE ALENCASTRO L. F., PULGARIN C. Degradation of 32 emergent contaminants by UV and neutral photo-fenton in domestic wastewater effluent previously treated by activated sludge. Water Res. 46, (6), 1947, 2012.
- 10. DIAZ M. E., LAWS E., FRANK J. Control of pathogenic microorganisms and turbidity in poultry-processing chiller water using UV-enhanced ozonation. Ozone Sci. Engin. 23, (1), 53, 2001.
- 11. LANGLAIS B., RECKHOW D. A., BRINK D. R. Ozone in Water Treatment, Applications and Engineering. Chelsea, MI, Lewis Publishers, Inc. 1991.
- 12. GARDONI D., VAILATI A., CANZIANI R. Decay of Ozone in Water: A Review. Ozone Sci. Engin. 34, (4), 233, 2012.
- 13. LINDENAUER K. G., DARBY J. L. Ultraviolet disinfection of wastewater: effect of dose on subsequent photoreac- tivation. Water Res. 28, 805, 1994.
- 14. BRAUNSTEIN J. L., LOGE F. J., TCHOBANOGLOUS G., DARBY J. L. Ultraviolet disinfection of filtered activated sludge effluent for reuse applications. Water Environ. Res. 68, 152, 1996.
- 15. GONCLAVES A. A., GAGNON G. A. Ozone Application in Recirculating Aquaculture System: An Overview. 33, (5), 345, 2011.
- 16. KSIBI M. Chemical oxidation with hydrogen peroxide for domestic wastewater treatment. Chem. Eng. J. 119, 161, 2006.
- 17. OLAŃCZUK-NEYMAN K., STOSIK-FLESZAR H., MIKOŁAJSKI S. Evaluation of Indicator Bacteria Removal in Wastewater Treatment Processes. Pol. J. Environ. Stud. 10, (6), 457, 2001.
- 18. WHITBY G. E., PALMATEER G. The effect of UV transmission, suspended solids and photoreactivation on microorganisms in wastewater treated with UV-light. Water Sci. Technol. 27, 379, 1993.
- 19. BRAHMI M., BELHADI N. H., HAMDI H., HASSEN A. Modeling of secondary treated wastewater disinfection by UV irradiation: Effects of suspended solids content. J. Environ. Sci. (China). 22, (8), 1218, 2010.
- 20. DAVIES-COLLEY R. J., DONNISON A. M., SPEED D. J., ROSS C. M., NAGELS J. W. Inactivation of faecal indicator microorganisms in waste stabilization ponds: interactions of environmental factors with sunlight. Water Res. 33, 1220, 1999.
- 21. KITIS M. Disinfection of wastewater with peracetic acid: a review. Environ. Int. 30, (1), 47, 2004.
- 22. BLANCHARD A. P., BIRD M. R., WRIGHT S. J. L. Peroxygen disinfection of Pseudomonas aeruginosa biofilms on stainless steel discs. Biofouling. 13, (3), 233, 1998.
- 23. JASIM S. Y., NDIONQUE S., ALSHIKH, O., JAMAL A. T. Impact of Ozone and Hydrogen Peroxide vs. UV and Hydrogen Peroxide on Chlorine Residual. Ozone Sci. Engin. 34, (1), 16, 2012.
- 24. SHARRER M. J., SUMMERFELT S. T. Ozonation followed by ultraviolet irradiation provides effective bacteria inactivation in a freshwater recirculating system. Aquacult. Eng. 37, (2), 180, 2007.
- 25. APHA, AWWA and WPCF. Standard Methods for the Examination of Water and Wastewater Washington, DC: American Public Health Association, 1998.
- 26. GEHR R., WAGNER M., VEERASUBRAMANIAN P., PAYMENT P. Disinfection efficiency of peracetic acid, UV and ozone after enhanced primary treatment of municipal wastewater. Water Res. 37, 4573, 2003.
- 27. XU P., JANEX, M. L., SAVOYE P., COCKX A., LAZARO- VA V. Wastewater disinfection by ozone: main parameters for process design. Water Res. 36, (4), 1043, 2002.
- 28. PARASKEVA P., GRAHAM N. J. D. Treatment of a secondary municipal effluent by ozone, UV and microfiltration: microbial reduction and effect on effluent quality. Desalination. 186, 47, 2005.
- 29. PARKER J. A., DARBY J. L. Particle associated coliform in secondary effluents: shielding from ultraviolet disinfection. Water Environ. Res. 67, (7), 1065, 1995.
- 30. SHARIF F., WANG J., WESTERHOFF P. Transformation in Bulk and Trace Organics during Ozonation of Wastewater. Ozone Sci. Engin. 34, (1), 26, 2012.
- 31. MELIDIS P., ATHANASOULIA E., PARISIS A., KOPPMANN M. Microbiological effluent control by UV-disin- fection of a small-scale SBR system. Desalination. 248, (13), 915, 2009.
- 32. WAGNER M., BRUMELIS D., GEHR R. Disinfection of wastewater by hydrogen peroxide or peracetic acid: development of procedures for measurement of residual disinfectant and application to a physicochemically treated municipal effluent. Water Environ. Res. 74, (1), 33, 2002.
- 33. ROSSI S., ANTONELLI M., MEZZANOTTE V., NURIZ- ZO C. Peracetic Acid Disinfection: A Feasible Alternative to Wastewater Chlorination. Water Environ. Res. 79, (4), 341, 2007.
- 34. YOON C. G., JUNG K. W., JANG J. H., KIM H. C. Microorganism repair after UV disinfection of secondary- level effluent for agricultural irrigation. Paddy Water Environ. 5, (1), 62, 2007.
- 35. SCIACCA F., RENGIFO-HERRERA J. A., WÉTHÉ J., PULGARIN C. Dramatic enhancement of solar disinfection (SODIS) of wild Salmonella sp. in PET bottles by H2O2 addition on natural water of Burkina Faso containing dissolved iron. Chemosphere. 78, (9), 1186, 2010.
- 36. GARCÍA-FERNÁNDEZ I., POLO-LÓPEZ M. I., OLLER I., FERNÁNDEZ-IBÁÑEZ P. Bacteria and fungi inactivation using Fe3+/sunlight, H2O2/sunlight and near neutral photo-Fenton: A comparative study. Applied Catalysis B: Environmental. 121, 20, 2012.
- 37. POLO-LÓPEZ M. I., GARCÍA-FERNÁNDEZ I., VELE- GRAKI T., KATSONI A., OLLER I., MANTZAVINOS D., FERNÁNDEZ-IBÁÑEZ P. Mild solar photo-Fenton: An effective tool for the removal of Fusarium from simulated municipal effluents. Applied Catalysis B: Environmental. 111, 545, 2012.
- 38. DUGNET J. P., ANSELME C., MAZONNIE P., MALLIVIALLE J. Application of combined ozone-hydrogen peroxide for the removal of aromatic compounds from groundwater. Ozone Sci. Engin. 12, (3), 281, 1990.
- 39. CRITTENDEN J., HU S., HAND D., GREEN S. A kinetic model for H2O2/UV process in a completely mixed batch reactor. Water Res. 33, 2315, 1999.
- 40. AHN K. H., PARK K. Y., MAENG S. K., SONG K. G., KIM K. P., LEE S. H., KWEON J. H. Color removal and disinfection with UV/H2O2 system for wastewater reclamation and reuse. Water Sci. Technol: Water Supply. 5, (1), 51, 2005.
- 41. GOMEZA E. O., IBANEZ P. F., MARTIN M.M. B., LÓPEZC M. I. P., GARClAA B. E., PÉREZA J. A. S. Water disinfection using photo-Fenton: Effect of temperature on Enterococcus faecalis survival. Water Res. In Press Accepted manuscript, 2012.
- 42. CHONG M. N., SHARMA A. K., BURN S., SAINT C. P. Feasibility study on the application of advanced oxidation technologies for decentralised wastewater treatment. Journal of Cleaner Production. 35, 230, 2012.
- 43. MACHADO Ê. L., KIST L. T., SCHMIDT R., HOELTZ J. M., DALBERTO D., ALCAYAGA E. L. A. Secondary hospital wastewater detoxification and disinfection by advanced oxidation processes. Environ Technol. 28, 1135, 2007.
- 44. ESCOBAR I., RANDALL A. Case Study: Ozonation and Distribution System Bio-stability. J. Am. Water Works As. 93, (10), 77, 2001.
- 45. ALONSO E., SANTOS A., RIESCO P. Micro-organism Re- Growth in Wastewater Disinfected by UV Radiation and Ozone: A Microbiological Study. Environ. Technol. 25, 433, 2004.
- 46. TOSA K., HIRATA T. Photo-reactivation of entero-hemor- rhagic E. coli following UV disinfection. Water Res. 33, 361, 1999.
- 47. SOMMER R., LHOTSKY T., HAIDER T., CABAJ A. UV inactivation, liquid-holding recovery and photoreactivation of Escherichia coli O157 and other pathogenic Escherichia coli strains in water. J. Food Protect. 63, 1015, 2000.
- 48. GILBAO Y., FRIEDLER E. UV disinfection of RBC treated light grey water effluent: Kinetics, survival and regrowth of selected microorganisms. Water Res. 42, 1043, 2008.
- 49. QUEK P. H., HU J. Indicators for photoreactivation and dark repair studies following ultraviolet disinfection. J. Ind. Microbiol. Biotechnol. 35, 533, 2008.
- 50. GUO M., HUANG J., HU H., LIU W., YANG J. UV inactivation and characteristics after photoreactivation of Escherichia Coli with Plasmid: Health Safety Concern about UV disinfection. Water Res. 46, (13), 4031, 2012.
- 51. SÜß J., VOLZ S., OBST U., SCHWART T. Application of a molecular biology concept for the detection of DNA damage and repair during UV disinfection. Water Res. 43, (15), 3705, 2009.
- 52. SCHWARTZ T., HOFFMANN S., OBST U. Formation of natural biofilms during chlorine dioxide and UV disinfection in a public drinking water distribution system. J. Appl. Microbiol. 95, (3), 591, 2003.
- 53. LEHTOLA M. J., MIETTINEN I. T., VARTIANEN T., RANTAKOKKO P., HIRVONEN A., MARTIKAINEN P. Impact of UV disinfection on microbially available phosphorous, organic carbon and microbial growth in drinking water. Water Res. 37, 1064, 2003.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-421f6b5a-88ee-4e82-8d8a-9daffdec4903