Warianty tytułu
Języki publikacji
Abstrakty
Men and women of different ages were submitted to the activity of negative or positive air-ions several hours a day for from several to more than a dozen days. Shifts in their systolic/diastolic pressures and pulse were determined in the course of these experiments. The tests have shown a statistically significant influence of the ionized particles, above all on blood pressure. Exposing humans with proper circulatory indicators six hours a day for more than a dozen days to negative air-ions in concentrations of 10,000 ions/cm³ results in a 5% drop in systolic pressure and around 2% drop in diastolic pressure, but has no influence on the pulse. This effect works until both pressures reach a stable level, which probably can be considered optimal for a given person. However, exposing people to positive air-ions in concentrations of 25,000 ions/cm³ results in destabilization of the circulatory indicators.
Słowa kluczowe
Wydawca
Czasopismo
Rocznik
Tom
Numer
Opis fizyczny
p.521-531,fig.,ref.
Twórcy
autor
- Faculty Department of Medical Informatics and Biostatistics, Medical University of Gdansk, Debinki 1, 80-211 Gdansk, Poland
autor
- Department of Physiotherapy, Jozef Rusiecki Olsztyn University College, Bydgoska 33, 10-243 Olsztyn, Poland
autor
- Department of Toxicology, Medical University of Gdansk, Hallera 107, 80-416 Gdansk, Poland
Bibliografia
- 1. GRABARCZYK Z.J. Air ionization in environment of life and of work. CIOP: Warszawa, 2000 [In Polish].
- 2. KAVET R.I., CHARRY J.M. Air-ions: Physical and Biological Aspects. Boca Raton, Florida: CRC Press, Inc., 1987.
- 3. DELEANU M., STAMATIU C. Influence of aeroionotherapy on some psychiatric symptoms. Int. J. Biometeorol. 29, (1), 91, 1985.
- 4. FLORY R., AMETEPE J., BOWERS B. A randomized, placebo-controlled trial of bright light and high-density negative air ions for treatment of Seasonal Affective Disorder. Psychiatry Research 177, (1-2), 101, 2010.
- 5. GIANNINI A.J., CASTELLANI S., DVOREDSKY A.E. Anxiety states: relationship to atmospheric cations and serotonin. J. Clin. Psychiatry, 44, (7), 262, 1983.
- 6. GIANNINI A.J., JONES B.T., LOISELLE R.H. Reversbility of seretonin irritation syndrome with atmospheric anions. J. Clin. Psychiatry 47, (3), 141, 1986.
- 7. HAWKINS L. The influence of air ions, temperature and humidity on subjective well beingand comfort. J. Environ. Psychol. 1, 279, 1981.
- 8. JURA Z., NIZIOŁ B., ZAKROCKI Z. Report No. 841 D of Institute of the Nuclear Physics. Ed. Institute of the Nuclear Physics: Kraków, 1973 [In Polish].
- 9. KORNIEWICZ H., GRABARCZYK Z., GRYZ K., KARPOWICZ J. Protection of human in work environment (CPBR No. 11.1). CIOP: Warszawa, 1991 [In Polish].
- 10. MALIK A., SINGH K., SINGH M. Effect of negative air ions on physiological and perceived psychological stress during computer operation. Int. J. of Environment and Health 4, (1), 67, 2010.
- 11. WISZNIEWSKI A., SZCZYGIEŁ M., HUDY S. Influence of Air-ions on Selected Microorganisms. Acta Microbiol. Pol. 52, (2), 201, 2003.
- 12. KLUSEK Z., WISZNIEWSKI A., JAKACKI J. Relationships between atmospheric positive electric charge densities and gas bubble concentrations in the Baltic Sea. Oceanologia 46, (4), 459, 2004.
- 13. SUCHANOWSKI A., WISZNIEWSKI A. Changes in ion concentration in the air during the breathing process of a human being. Pol. J. Environ. Stud. 8, (4), 259, 1999.
- 14. WISZNIEWSKI A. Natural environment of air-ions. Med. Pr. 48, (4), 427, 1997 [In Polish].
- 15. WISZNIEWSKI A. Changes of the air ionization caused by electric discharge in the atmosphere. Ann. Acad. Med. Gedan. 34, 341, 2004 [In Polish].
- 16. WISZNIEWSKI A. Air ionization in flats and offices. Hig. Pr. 3, 37, 1997 [In Polish].
- 17. WISZNIEWSKI A. Normalization and optimization of air ionization levels in the atmosphere of populated areas. Med. Pr. 61, (2), 441, 2010 [In Polish].
- 18. WISZNIEWSKI A., BARAN M. Changes in the state of air ionization caused by medical equipment. Med. Pr. 52, (4), 271, 2001 [In Polish].
- 19. WISZNIEWSKI A., JANCZEWSKI D. Air-ions and their influence on human and animal organisms. Med. Pr. 3, 289, 1993 [In Polish].
- 20. SCHREIBER G.O.S., PEYROUS R. Some air ion measurements made in the Pyrenees (France) at altitudes of 200 m and 2970 m. Int. J. Biometeorol. 23, (2), 123, 1979.
- 21. WISZNIEWSKI A. Environment of air-ions in ship cabins and possibility of its optimization. Med. Pr. 61, (3), 299, 2010 [In Polish].
- 22. WISZNIEWSKI A., KRETOWICZ T. A study on influence of different signs of air-ions on sister-chromatid exchange frequency and chromosome aberrations in human peripheral blood lymphocytes. J. Appl. Genet. 40, (2), 129, 1999.
- 23. WISZNIEWSKI A., SUCHANOWSKI A. The Influence of Air-ions on People Submitted to Physical Effort and in Rest. Pol. J. Environ. Stud. 17, (5), 801, 2008.
- 24. SIROTA T.V., SAFRONOVA V.G., AMELINA A.G., MALTSEVA V.N., AVKHACHEVA N.V., SOFIN A.D., YANIN V.A., MUBARAKSHINA E.K., ROMANOVA L.K., NOVOSELOV V.I. The effect of negative air ions on the respiratory organs and blood. Biophysics 53, (5), 457, 2008.
- 25. SOVIJARI A.R., ROSSET S., HYVARINEN J., FRANSSILA A., GRAEFFE G., LEHTIMAKI M. Effect of air ionization on heart rate and perceived exertion during a bicycle exercise test, a double-blind cross-over study. Europ. J. App. Physoliogy & Occup. Physiology 41, (4), 285, 1979.
- 26. WATANABE I., NORO H., OHTSUKA Y., MANO Y., AGISHI Y. Physical effects of negative air ions in a wet sauna. Int. J. Biometeorol. 40, 107, 1997.
- 27. GRASSI G., CIFKOVA R., LAURENT S., NARKIEWICZ K., REDON J., FARSANG C., VIIGIMAA M., ERDINE S., BRAMBILLA G., BOMBELLI M., DELL'ORO R., NOTARI M., MANCIA G. Blood pressure control and cardiovascular risk profile in hypertensive patients from central and eastern European countries: results of the BP-CARE study. Eur. Heart J. 32, (24), 218, 2011.
- 28. HEDNER T., KJELDSEN S., NARKIEWICZ K., OPARIL S. Blood pressure and migration. Blood Press, 19, (2), 65, 2010.
- 29. PRYSTUPA T., WOŁYŃSKA A., ŚLEŃSKI J. The effects of finish sauna on hemodynamics of the circulatory system in men and women. J. of Human Kinetics 22, (1), 100, 2009.
- 30. KELLOGG III E.W., YOST M.G., BARTHAKUR N., KRUEGER A.P. Superoxide involvment in the bactericidal effects of negative air ions on Staphylococcus albus. Nature 281, (4), 400, 1979.
- 31. MARTINAC I. On the biological effects of small air ions and the use of ionizers in occupied indoor environments. Kungl. Techniska Högskolan – A4 – serien nr 141, Falu Bookproduktion: Falun, 1993.
- 32. KELLOGG III E.W., YOST M.G., REED E.Y., KRUEGER A.P. Long-term biological effects of air ions and D.C. electric fields on NAMRU mice: second year report. Int. J. Biometeorol. 29, (3), 269, 1985.
- 33. KRUEGER A.P., REED E.J., BROOK K.B., DAY M.B.. Air ion action on bacteria. Int. J. Biometeorol. 19, 65, 1975.
- 34. KRUEGER A.P., STRUBBE A.E., YOST M.G., REED E.J. Electric fields, small air ions and biological effects. Int. J. Biometeorol. 22, (3), 202, 1978.
- 35. KRUEGER A.P. The biological effects of air ions. Int. J. Biometeorol. 29, (3), 205, 1985.
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.agro-29bfa099-85f7-4aa9-a829-1239a477aeb0