Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl

PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Czasopismo
2010 | 5 | 4 | 452-455
Tytuł artykułu

Narrow band imaging technology and argon plasma coagulation in treatment of preneoplastic lesions in a 45-year-old male

Treść / Zawartość
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Early detection and treatment of preneoplastic lesions represents an obvious option to reduce morbidity and mortality from lung malignancies. Until now, radiological detection, sputum cytology, and autofluorescence have shown limited effectiveness as screening methods. Novel technologies such as Narrow Band Imaging (NBI) are showing promising results, but new studies are still needed to evaluate their use as screening methods. Together with early detection, adequate methods of lesion treatment, such as argon plasma coagulation, are needed. This case report concerns a 45-year-old man who was referred for bronchoscopy after his annual checkup. Using NBI technology, a preneoplastic lesion was identified, and treated using argon plasma coagulation. Our experience has shown us that both NBI screening and argon plasma coagulation are very promising, easily implemented, methods.
Wydawca

Czasopismo
Rocznik
Tom
5
Numer
4
Strony
452-455
Opis fizyczny
Daty
wydano
2010-08-01
online
2010-05-30
Twórcy
autor
  • Polyclinic for lung diseases, Healthcare Center Tuzla, Tuzla, 75 000, Bosnia and Herzegovina
  • Polyclinic for lung diseases, Healthcare Center Tuzla, Tuzla, 75 000, Bosnia and Herzegovina
autor
  • Medical faculty, University Mostar, Mostar, 88 000, Bosnia and Herzegovina
  • Department of pathology, Medical faculty, University Sarajevo, Sarajevo, 71 000, Bosnia and Herzegovina
autor
  • Department of pathology, Medical faculty, University Sarajevo, Sarajevo, 71 000, Bosnia and Herzegovina
Bibliografia
  • [1] Cotran R.S., Kumar V., Collins T., Robbins Pathologic Basis of Diseases, sixth edition, W. B. Saunders, London, 1999
  • [2] Franco E.L., Rohan T.E., Cancer Precursors: Epidemiology, Detection, and Prevention, Springer, New York 2001
  • [3] Breuer R.H.J., Snijders P.J. F., Sutedja T.G., v d Linden H., Risse E.K.J., Meijer C.J.L., et al., Suprabasal p53 immunostaining in premalignant endobronchial lesions in combination with histology is associated with bronchial cancer. Lung cancer 2003, 40, 165–172 http://dx.doi.org/10.1016/S0169-5002(03)00029-1
  • [4] Häußinger K., H Becker H., F Stanzel F., A Kreuzer A, B Schmidt B., J Strausz J, S Cavaliere, F Herth, M Kohlhäufl, K-M Müller, R-M Huber, U Pichlmeier and Ch T Bolliger et al., Autofluorescence bronchoscopy with white light bronchoscopy compared with white light bronchoscopy alone for the detection of precancerous lesions: a European randomized controlled multicentre trial, Thorax Journal Jun, 2005, 60, 496–503 http://dx.doi.org/10.1136/thx.2005.041475[Crossref]
  • [5] Fisseler-Eckhoff A., Rothstein D., Muller K.M., Neovascularization in hyperplastic, metaplastic and potentially preneoplastic lesions of the bronchial mucosa, Virchows Arch 1996, 429, 95–100 http://dx.doi.org/10.1007/BF00192431[Crossref]
  • [6] Vincent B.D., Fraig M, Silvestri G.A., Narrow band imaging compared to white light bronchoscopy for evaluation of normal, pre-malignant and malignant airways disease, Chest, 2007, 131, 1794–1799 http://dx.doi.org/10.1378/chest.06-2794[WoS][Crossref]
  • [7] Crosta C., Spaggiari L., Stefano A.D., Fiori G., Ravizza D., Pastorino Endoscopic argon plasma coagulation for palliative treatment of malignant airway obstructions: early results in 47 cases, Lung Cancer, 2001, 33, 75–80 http://dx.doi.org/10.1016/S0169-5002(00)00245-2[Crossref]
  • [8] Schuurman B., Postmus P.E., van Mourik J.C., Risse E.K., Sutedja T.G., Combined use of autofluorescence bronchoscopy and argon plasma coagulation enables less extensive resection of radiographically occult lung cancer, Respiration, 2004, 71, 410–411 http://dx.doi.org/10.1159/000079648[Crossref]
Typ dokumentu
Bibliografia
Identyfikatory
Identyfikator YADDA
bwmeta1.element.-psjd-doi-10_2478_s11536-010-0009-6
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.