EN
This paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations were conducted in the PLECS program using a control algorithm written in C programming language.
EN
The article presents the methodology for testing dynamic states of a large-power salient-pole synchronous motor with a periodically variable load using the method of small oscillation stability. The analytical relationship taking into account the periodically variable load, which enables to obtain results without the need for numerical integration, is presented. The possibility of decreasing the motor field current in terms of using the motor in the automatic reactive power compensation system was considered. The effect of voltage dips on the motor's operation was investigated. Selected research results have been presented and discussed. The method errors have been discussed.
PL
W artykule przedstawiono metodykę badań stanów dynamicznych silnika synchronicznego jawnobiegunowego dużej mocy z okresowo zmiennym obciążeniem metodą małych wychyleń wirnika. Przedstawiono zależność analityczną uwzględniającą okresowo zmienny charakter obciążenia umożliwiającą uzyskanie wyników bez konieczności całkowania numerycznego. Rozpatrzono możliwość obniżenia prądu wzbudzenia silnika pod kątem wykorzystania w systemie automatycznej kompensacji mocy biernej. Zbadano wpływ zapadów napięcia na pracę silnika. Zamieszczono i omówiono przykładowe wyniki badań. Omówiono błędy metody.
EN
The paper deals with an AC circuit containing the nonlinear load and a LC passive filter. Nonlinear load voltage at the power terminals proportional to the signum function of current is considered. The current-voltage characteristic of such load is unambiguous (without hysteresis). A quality analysis of the circuit voltages and currents was carried out. Distribution of active and reactive power for fundamental and higher harmonics in the circuit were also performed.
PL
W pracy analizowany jest obwód prądu przemiennego z przykładowym obciążeniem nieliniowym i filtrem biernym LC. Przyjęto obciążenie nieliniowe, którego napięcie na zaciskach zasilania jest proporcjonalne do funkcji signum prądu. Charakterystyka napięciowo - prądowa obciążenia jest jednoznaczna (bez histerezy). Przeprowadzono analizę jakościową przebiegów napięć i prądów obwodu. Wykonano analizy rozkładu mocy czynnej i biernej dla harmonicznej podstawowej i wyższych harmonicznych w obwodzie.
PL
W pracy przedstawiono wyniki badania strat mocy w układzie kompensatora mocy biernej zbudowanego z baterii kondensatorów i dławików ochronnych. Zaprezentowane wyniki poddano analizie pod kątem możliwości zabudowania kompensatora w przeciwwybuchowej obudowie ognioszczelnej do zastosowania w sieci niskiego napięcia wyrobisk kopalni z zagrożeniem wybuchu metanu i pyłu węglowego.
EN
The results of power losses in the reactive power compensator built of capacitor banks and protective chokes have been presented in the paper. The showed results were analyzed for the possibility of installing the compensator in a flameproof explosion-proof enclosure for use in the low-voltage network of mine headings with the risk of methane and coal dust explosion.
PL
W artykule omówiono możliwości zastosowania regulatorów mocy biernej w układach jej kompensacji. Zwrócono uwagę na wymagania prawne dotyczące przekładników prądowych.
EN
The article discusses the possibilities of using reactive power controllers in compensation systems. Attention was paid to legal requirements for current transformers.
EN
The cooperation of wind farms with the power system requires that they meet the requirements related to reactive power management. In practice, it concerns both generation and production of this power in accordance with the requirements of network operators and EU Regulation 2016/631. The regulatory capacity of wind turbine generators is not sufficient to meet these requirements, in particular for farms connected to the power system via a 110 kV cable line with a length of several dozen kilometers. It is required to use various additional devices – fixed or variable shunt reactor, capacitor batteries, static VAR compensators (SVC). In the article, a compensation quality indicator was defined, by means of which it is possible to assess and select the optimal set of devices supporting the farm’s generation and reactive power consumption capabilities. Due to the application of multicriteria optimization, this indicator unifies both the technical effectiveness of individual systems and the economies of their use.
EN
The construction and installation of high-power wind farms triggers a number of problems related to the compensation of HV cable lines exporting power from a wind farm, and to the choice of compensation devices. The article describes problems that occur when wind farms are connected to the power system with a 110 kV line, characterizes the devices determining the reactive power balance. Two reactive power compensation systems FSR and STATCOM were also analyzed for minimizing the costs of compensation systems.
PL
Kopalniane maszyny wyciągowe z napędami tyrystorowymi są bardzo specyficznymi, niespokojnymi, generującymi wyższe harmoniczne prądu odbiorami energii elektrycznej. Stosunkowo duża moc tych odbiorów rzutuje znacząco na jakość energii elektrycznej w układach zasilającorozdzielczych kopalń. Jednym z podstawowych problemów jest kompensacja mocy biernej w środowisku wyższych harmonicznych. W artykule przedstawiono podstawowe rozwiązania techniczne w tym zakresie.
EN
Mining hoists with thyristor drives are very specific, distributive and current harmonics generating electric loads. The relatively high power of these loads significantly affects the quality of electricity in the mine's supply and distribution systems. One of the most important problems is reactive power compensation in a harmonic environment. The article presents general technical solutions in this area.
PL
W pracy analizowany jest obwód prądu przemiennego z przykładowym obciążeniem nieliniowym i filtrem biernym LC. Przyjęto obciążenie nieliniowe, którego napięcie na zaciskach zasilania jest proporcjonalne do funkcji signum prądu. Charakterystyka napięciowo - prądowa takiego obciążenia jest jednoznaczna (bez histerezy). Przeprowadzono analizę jakościową przebiegów napięć i prądów obwodu. Wykonano analizy przepływu mocy czynnej i biernej dla harmonicznej podstawowej i wyższych harmonicznych w obwodzie.
EN
The paper deals with the AC circuit with an example of a non-linear load and an LC passive filter. The voltage on the nonlinear load terminals is proportional to the signum function of the current. The voltage - current characteristic of such load is unambiguous (without hysteresis). The quality analysis of the voltage and current waveforms of the circuit was carried out. The analysis of active and reactive power flow for fundamental and higher harmonics in the circuit were carried out.
PL
Przedstawiono wyniki symulacyjnych badań instalacji przemysłowej przy zastosowaniu różnych sposobów kompensacji mocy biernej oraz wpływ wybranego sposobu kompensacji mocy biernej na koszty energii elektrycznej.
EN
The article presents the results of simulation of industrial installation work with using various methods of reactive power compensation and the influence of selected method of reactive power compensation on electricity costs.
11
PL
W artykule rozważono aktualny problem kompensacji mocy biernej w sieciach elektrycznych z nieliniowymi szybkozmiennymi obciążeniami, takimi jak elektryczne piece łukowe, napędy walcownicze, itp. Właściwością pracy tego rodzaju obciążeń jest wprowadzanie do sieci zasilającej interharmonicznych prądu (wraz z wyższymi harmonicznymi) i stosunkowo niski współczynnik mocy. W związku z tym istnieje potrzeba oceny doboru mocy urządzeń kompensujących z uwzględnieniem losowego charakteru odkształcenia przebiegów prądu i napięcia, a w szczególności składowych interharmonicznych, których wpływ jak dotychczas nie został w pełni zbadany.
EN
The paper discusses the current problem of reactive power compensation in electric networks with non-linear fast-changing loads, such as electric arc furnaces, rolling machines, etc. Operation of this kind of loads causes that interharmonic currents (together with higher harmonics) are injected into the supply network and a relatively low power factor. Therefore, there is a need to evaluate the power selection of compensating devices, taking into account the random nature of distortion of current and voltage waveforms, in particular interharmonic components whose impact has not been fully investigated so far.
EN
This paper presents advantage of using a FACTS device for dynamic Reactive Power compensation. Simulation model was built in MATLAB Simulink software to prove mathematical constraints. Determination of the most favourable location and size of the compensation devices from the aspect of losses, power quality, costs are calculated as a fitness function developed by genetic algorithm. Optimisation was done by Particle swarm optimization (PSO). Finally, cut convergence time and significant potential of usage such type of PSO optimisation method for determination of future investments are shown. This algorithm is tested to determine optimal location of FACTS device in railway application, instead of the methods and algorithms in transmission or distribution power system used until now.
PL
W artykule zaprezentowano korzyści ze stosowanie FACTS do dynamicznej kompensacji mocy biernej. Symulacje miały na celu określenie najlepszego położenia i roz,miaru urządzeń kompensujących z punktu widzenia jakości energii i kosztów. Zastosowano algorytm genetyczny PSO do optymalizacji i analizy przyszłych inwestycji.
PL
W artykule przedstawiono problemy dotyczące kompensacji mocy biernej w sieciach przesyłowych ze szczególnym zwróceniem uwagi na problem ich lokalizacji i doboru podstawowych parametrów. Uwagę skupiono na nowoczesnych układach energoelektronicznych, zapewniających pełną automatyczną regulację kompensatora według kryteriów napięciowych lub mocowych.
EN
The article discusses issues of reactive power compensation in transmission grids, with particular focus on the selection of compensator locations and basic parameters. Attention was focused on modern power electronics systems that ensure full automatic compensator adjustment to voltage or power criteria.
PL
Jednym z elementów odbudowy systemu elektroenergetycznego w przypadku blackoutu jest wybór toru rozruchowego zapewniającego odpowiednie parametry układu m.in. napięcia na elementach. Podstawowym problemem jest tutaj wzrost napięcia na elementach toru związany z wystąpieniem w torze mocy biernych pojemnościowych linii. W artykule, na podstawie obliczeń dla toru między EW Dychów, a Elektrownią Dolna Odra, zostanie przedstawiona metoda kompensacji z użyciem transformatorów 220 kV połączonych równolegle.
EN
One of the elements of the power system reconstruction in the case of a blackout is the selection of a start-up track that ensures appropriate parameters of the system, including voltage on elements. The main problem here is the increase in the voltage on the track elements associated with the occurrence of passive capacitive lines in the track. In the article, based on calculations for the track between EW Dychów and Dolna Odra Power Plant, the compensation method will be presented using 220 kV transformers connected in parallel.
EN
Reactive power compensation is one of the leading ways to improve the power transmission efficiency. Currently, there is a problem of increasing the calculations accuracy for compensating devices selection and their application feasibility. The development of smart grids creates an information base that enables refined solution of such problems. We examine one of the ways to increase the accuracy in this work – it is the consideration of temperature dependence of the network resistance elements. In this case, we specify as the optimal values of power compensation devices, as payback periods. Moreover, the clarification for payback period could exceed 100%. We can apply a similar approach to other measures to reduce energy losses, and it opens up an additional field of research. We can use the results obtained in this study both as for power industrial systems, as for urban and rural distribution networks.
PL
W niniejszej pracy rozpatrzono jeden ze sposobów zwiększenia precyzji kompensacji mocy – post temperaturowe zależności oporów elementów sieci. Określone optymalne wartości mocy urządzeń kompensacyjnych na podstawie okresu zwrotu. Podobne podejście można zastosować również do innych metod w celu zmniejszenia strat energii. Wyniki uzyskane w tej pracy, mogą być stosowane w systemach zasilania zakładów przemysłowych, a także w miejskich i wiejskich sieciach rozdzielczych.
17
EN
The paper presents the concept, implementation and operational effects of the multi-servers automatic reactive power compensation system in 6 kV industry electrical power grid. As controlled reactive power compensators were used synchronous motors, capacitors’ banks and passive filters of higher harmonics available in the power grid of the plant. System of communication and collaboration of control servers with databases was disclosed. Use of events technology of Firebird database was discussed. Clients’ application for industry grid state and compensation system monitoring were presented. Results of operation and planned modernization of the system was presented.
PL
W artykule przedstawiono koncepcję, realizację praktyczną oraz efekty działania wieloserwerowego systemu automatycznej kompensacji mocy biernej w przemysłowej sieci elektroenergetycznej 6 kV. Jako kompensatory mocy biernej wykorzystane zostały silniki synchroniczne, baterie kondensatorów i pasywne filtry wyższych harmonicznych pracujące w zakładzie. Przedstawiono system informatyczny i współpracę z bazą danych. Omówiono wykorzystanie technologii zdarzeń bazy danych Firebird w prezentowany rozwiązaniu. Przedstawiono oprogramowanie klienckie wykorzystywane do monitorowania pracy systemu i stanu sieci elektroenergetycznej. Przedstawiono przykładowe efekty działania oraz propozycje dalszych prac związanych z modernizacją systemu.
18
Content available remote Model matematyczny synchronicznego układu pompowego o podatnej transmisji ruchu
PL
W pracy, wychodząc z interdyscyplinarnych podejść, opracowano model matematyczny układu pompowego dużej mocy, składającego się z silnika synchronicznego o biegunach jawnych, który przez podatną transmisję ruchu napędza pompę pionową. Transmisje ruchu rozpatruje się, jako ekwiwalentne sprzęgło elastyczne o mechanicznych parametrach skupionych. Ogólne różniczkowe równania elektromechaniczno-hydraulicznego stanu przedstawione są w postaci Cauchy'ego. Wyniki symulacji komputerowej przedstawione są w postaci rysunków.
EN
In the article, a mathematical model of a high power pump system was developed. The pump system consists of a synchronous motor with non-salien t poles, a clutch that provides a susceptible movem ent transmission and a vertical pump. The model was developed based on an interdisciplinary approach. Move - ment transmissions are considered as an equivalent flexible coupling with mechanical clustered parameters. General differential equations of electro-mechanical-hydraulic state are presented in the Cauchy form. The results of the computer simulation are presented in the figures.
PL
W drugiej części artykułu przedstawiono analizę wyników badań układów elektroenergetycznych z zastosowanym filtrem aktywnym.
EN
The second part of the article presents the results of measurements in the system supplying the industrial plant with active filter turned on and off.
PL
W artykule zaprezentowano korzyści wynikające z zastosowania układów ultraszybkiej kompensacji mocy biernej. Układ ultraszybkiej kompensacji to system poprawy jakości energii w czasie rzeczywistym, który zapewnia: poprawę współczynnika mocy, oszczędność energii, kontrolę i kondycjonowanie napięcia poprzez: redukcję migotania, redukcję przepięć i skoków prądu, filtrację harmonicznych oraz dużo więcej zastosowań dla różnych obciążeń dynamicznych. Urządzenie realizujące ultraszybką kompensację to Equalizer.
EN
The article presents the benefits resulting from the use of ultra-fast passive reactive power compensation systems. The ultra-fast compensation system is a real-time power quality improvement system that provides: power factor improvement, energy saving, control and conditioning of the voltage by: reduction of flicker, reduction of overvoltage and jumps of current, harmonic filtration and many more applications for different dynamic loads. The device that performs ultra-fast compensation is the Equalizer.