Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 995

Liczba wyników na stronie
first rewind previous Strona / 50 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Oprogramowanie
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 50 next fast forward last
EN
The article discusses the software proposed by the authors for selecting the optimal option for installing a photo-video fixation system of traffic violations. The software uses the Microsoft Visual FoxPro 9.0 programming language, which is simple, easy to use and provides an overview of the technical solution in the application of the ITS system.
EN
Pavements require regular maintenance due to the wear and tear caused by traffic loads and environmental conditions, which lead to various surface defects. This study explores the use of Light Detection and Ranging (LiDAR) technology and ArcGIS software to identify pavement defects in selected regions of Malaysia. The Jambatan Sultan Abdul Halim Muadzam Shah Expressway (JSAHMSE) and the Guthrie Corridor Expressway (GCE) were chosen as test sites for evaluating this approach. Initially, point cloud data were collected from both expressways using LiDAR, and related images were processed through ArcGIS software to identify defects on the road surfaces. The analysis revealed defects such as shoving, bleeding, longitudinal cracking, potholes, and patching on the GCE, while raveling, longitudinal cracking, bleeding, and edge cracking were observed on the JSAHMSE. Simultaneously, manual visual inspections were conducted, and defects were documented. A comparison of the results from both methods showed that LiDAR and ArcGIS effectively identified the types and sizes (length and surface area) of the defects. However, ArcGIS struggled to accurately measure the depth of certain defects, making it difficult to assess their severity in detail.
EN
The transformation of contemporary enterprises is a complex and multifaceted process that should be integrated into their development strategy. One of the manifestations of this transformation is the tendency of enterprises to implement and actively use specific software and IT systems, such as extranets, simple spreadsheets and text editors, relational da- tabase systems, project management software, remote desktop software, CRM systems, and Business Intelligence systems. The article’s primary objective is to identify the software and IT systems used in innovative enterprises and to assess the overall complexity of this phenomenon from the perspective of Poland’s regions. The basis for the analysis is the division of Poland into regions (created by voivodeships) with various levels of innovation potential. The study used a diagnostic survey. The research technique consists of CAWI interviews conducted with a random sample of 200 respondents – business owners or managers responsible for computerization/digitization processes, innovation processes, or project management employed in companies operating in Poland’s most innovative sectors. The study covered the entire area of Poland (16 voivodeships). The CAWI questionnaire was based on respondents’ opinions, using a 5-point scale. The study revealed that the specified regions in Poland do not differ statistically in terms of the use of specific software and IT systems. Additionally, the complexity of utilizing software and IT systems in innovation processes is moderately high. The most commonly used IT solutions include email accounts, intranets, simple spreadsheets, simple text editors, and antivirus software.
PL
Transformacja współczesnych przedsiębiorstw jest działaniem złożonym i wieloaspektowym, które powinno być wpisane w strategię ich rozwoju. Jednym z przejawów wspomnianej transformacji jest skłonność przedsiębiorstw do implementacji i aktywnego stosowania określonego oprogramowania i systemów IT, np. sieci extranet, prostych ar kuszy kalkulacyjnych i edytorów tekstu, systemów relacyjnych baz danych, oprogramowania do zarządzania projektami, oprogramowania do zdalnego pulpitu czy też systemów klasy CRM i Business Intelligence. Głównym celem artykułu jest wskazanie, które oprogramowanie i systemy informatyczne są wykorzystywane w innowacyjnych przedsiębiorstwach, oraz oszacowanie ogólnej złożoności tego zjawiska w perspektywie regionów Polski. Podstawą analiz jest podział Polski na regiony (tworzone przez województwa) o różnym poziomie potencjału innowacyjnego. W badaniu zastosowano metodę sondażu diagnostycznego. Technika badawcza to wywiady CAWI przeprowadzone na losowej próbie 200 respondentów – właścicieli przedsiębiorstw lub menedżerów odpowiedzialnych za procesy informatyzacji/cyfryzacji, procesy innowacyjne lub zarządzanie projektami, za trudnionych w przedsiębiorstwach prowadzących działalność w Polsce w najbardziej innowacyjnych sektorach. Badaniem objęto całą Polskę (16 województw). W kwestionariuszu ankiety CAWI bazowano na opiniach respondentów z wykorzystaniem 5-stopniowej skali. Badanie wykazało, że wyszczególnione regiony w Polsce nie różnią się między sobą statystycznie pod kątem stosowania określonego oprogramowania i systemów IT. Ponadto złożoność wykorzystania w procesach innowacyjnych określonego oprogramowania i systemów IT jest na umiarkowanie wysokim poziomie. Najczęściej stosowanymi rozwiązaniami IT są: konta mailowe, sieć intranet, proste arkusze kalkulacyjne, proste edytory tekstu, jak również oprogramowanie antywirusowe.
PL
W artykule przedstawiono system COLCON oparty o monitoring temperatury we wczesnej fazie dojrzewania mieszanki betonowej z zastosowaniem wielopoziomowego podejmowania decyzji na 3 zasadniczych poziomach (i w wielu etapach): planowaniu opartym na współczynnikach sezonowości, eliminacji efektów zakłóceń z wykorzystaniem elastyczności biernej (odporności) poprzez zastosowanie odpowiednich modyfikacji mieszanki betonowej oraz elastyczności czynnej (adaptacyjności) – uwzględniając możliwości sterowania nagrzewem elementu w oparciu o monitoring, prognozę pogody i symulację procesu narastania wytrzymałości betonu w przypadku zaistnienia scenariusza pesymistycznego. Opracowany system został wykorzystany podczas badań laboratoryjnych i na budowie, a zebrane dane posłużyły do generowania reguł decyzyjnych w oparciu o uczenie się z przykładów z wykorzystaniem specjalistycznego oprogramowania RapidMiner z zastosowaniem algorytmów Decision Tree oraz Random Forest.
EN
The article presents the COLCON system, which is based on temperature monitoring during the early stage of concrete mix curing, using multi-level decision-making on three fundamental levels (and in multiple stages): planning based on seasonality coefficients, eliminating disturbance effects through the use of passive flexibility (resilience) by applying appropriate modifications to the concrete mix, and active flexibility (adaptability) – taking into account the possibility of controlling the heating of the element based on monitoring, weather forecasting, and simulation of the concrete strength development process in the event of a pessimistic scenario. The developed system was used in laboratory tests and on a construction site, and the collected data served to generate decision rules based on learning from examples using specialized RapidMiner software, employing Decision Tree and Random Forest algorithms.
PL
Celem artykułu jest porównanie budynku przykładowego z dwoma typami dachów, pierwszy z klasycznym dachem z konstrukcją drewnianą, membraną i pokryciem, drugi – zielony ze niezbędnymi warstwami (modelem pobranym ze strony producenta). W niniejszym artykule zostaną zaprezentowane wyniki z modelu, wykonanego w programie Autodesk Revit oraz przeanalizowanego przez program Autodesk Insight, jednego budynku o wariantowym rodzaju dachu. Zielony dach został wybrany do analizy ze względu na właściwości oferowane przez tę technologię, nie tylko dobrze znane właściwości termiczne, ale także dodatkowe aspekty, takie jak obniżenie zużycia energii oraz pozytywny wpływ na środowisko.
EN
The purpose of this paper is to compare an example building with two roof types, the first with a classic roof with timber structure, membrane and covering, the second with a green roof with the necessary layers (model downloaded from the manufacturer’s website). This paper will present results from a model, made in Autodesk Revit and analysed by Autodesk Insight, of one building with a variant roof type. The green roof was chosen for the analysis because of the properties offered by this technology, not only the well-known thermal properties, but also additional aspects such as reduced energy consumption and positive environmental impact.
6
Content available remote Visual Components Robotics Oprogramowanie OLP nowej generacji
PL
Robot Offline Programming (OLP) to metoda programowania robotów przemysłowych w wirtualnym środowisku symulacyjnym – programie komputerowym, bazującym na danych CAD 3D. Po napisaniu i zweryfikowaniu programu w symulacji można go wgrać i odtworzyć za pomocą aktualnie używanego robota (manipulatora).
EN
The article discusses briefly the influence of trends and changes in contemporary concrete construction on technological and organizational aspects of work planning. In this context, a technique for analyzing the efficiency of system formwork utilization was also proposed; it uses available engineering software for scheduling construction works. The method was illustrated with an example from a real construction site.
PL
W artykule przedstawiono problematykę wpływu trendów i zmian zachodzących we współczesnym budownictwie betonowym na technologiczne i organizacyjne aspekty planowania robót. W tym kontekście zaproponowano także technikę analizy efektywności wykorzystania deskowań systemowych, wykorzystującą dostępne oprogramowanie inżynierskie do harmonogramowania robót budowlanych. Metoda została zilustrowana przykładem z realnej budowy.
EN
The paper presents a case study concerning the foundation of a multi‑storey residential building situated in Krakow, developed under challenging geotechnical and urban conditions. The building comprises eleven above‑ground and two underground storeys, and necessitating a deep excavation in close proximity to existing structures. In order to achieve uniform settlement and minimise the risk of cracking in the rigid reinforced concrete walls, the interaction between pile groups and diaphragm walls was analyzed in GEO5, ABC‑Płyta, and ABC‑Tarcza software suites. The numerical results were subsequently compared with field measurements, revealing a high level of concordance and thereby validating the adopted design methodology.
PL
Artykuł omawia przypadek wielokondygnacyjnego budynku mieszkalnego w Krakowie, posadowionego w trudnych warunkach gruntowo‑wodnych i gęstej zabudowie miejskiej. Budynek składa się z jedenstu kondygnacji nadziemnych oraz dwóch podziemnych, a jego realizacja wymagała głębokiego wykopu w sąsiedztwie istniejącej zabudowy. W celu zapewnienia równomiernego osiadania oraz minimalizacji ryzyka zarysowania sztywnych żelbetowych ścian budynku przeanalizowano współpracę grup pali i ścian szczelinowych przy użyciu programów GEO5, ABC‑Płyta i ABC‑Tarcza. Wyniki odniesiono do rzeczywistych pomiarów, a przeprowadzona analiza wykazała bardzo dobrą zgodność.
PL
W artykule zaprezentowano wyniki oryginalnego badania dotyczącego wpływu wybranych parametrów geometrycznych i materiałowych. Przeanalizowana pod kątem temperaturowym została strefa przyziemia budynku obejmującego połączenie ściany zewnętrznej z fundamentem i podłogą na gruncie. Analizie poddano zależność temperatury występującej w miejscu krytycznym węzła wewnątrz przegrody zewnętrznej. Przeanalizowano następujące zmienne: X1– współczynnik przewodzenia ciepła warstwy izolacyjnej ułożonej na płycie fundamentowej [W/(m·K)], X2 – grubość warstwy styropianu w strefie cokołowej [m], X3 – grubość izolacji cieplnej pod płytą fundamentową [m], X4 – grubość termoizolacji zastosowanej w ścianie zewnętrznej [m], X5 – grubość izolacji wewnętrznej części cokołowej fundamentu [m]. Obliczenia wykonano dla warunków klimatycznych charakterystycznych dla miasta Białystok, przy użyciu oprogramowania THERM. Na podstawie wyników symulacji opracowano deterministyczne modele matematyczne, które umożliwiły ocenę charakteru i siły oddziaływania poszczególnych czynników na temperaturę w miejscu występowania mostka termicznego. Jak wykazały obliczenia, największy jednostkowy wpływ spośród analizowanych czynników wykazuje zmienna X5, odpowiadająca za grubość izolacji wewnętrznej części cokołowej fundamentu [m]. Wartość współczynnika przy tej zmiennej wynosi 2,5673, co oznacza, że przejście z poziomu -1 na +1 skutkuje wzrostem średniej temperatury o ok. 5,13°C. Uzyskane wyniki mogą stanowić cenne źródło informacji dla naukowców, projektantów, inżynierów oraz decydentów, wspierając podejmowanie trafnych decyzji na etapie projektowania budynków z ogrzewaną przestrzenią użytkową.
EN
The article presents the results of an original study on the impact of selected geometric and material parameters. The thermal performance of the ground-level zone of a building was analysed, focusing on the connection between the external wall, foundation, and ground floor. The study examined the temperature at the critical point within the external partition. The following variables were analysed: X1 – thermal conductivity of the insulation layer placed on the foundation slab [W/(m·K)], X2 – thickness of the polystyrene layer in the plinth area [m], X3 – thickness of thermal insulation under the foundation slab [m], X4 – thickness of thermal insulation used in the external wall [m], X5 – thickness of internal insulation of the foundation wall [m]. Calculations were performed for the climatic conditions characteristic of the city of Białystok using the THERM software. Based on the simulation results, deterministic mathematical models were developed, enabling the assessment of the nature and strength of the influence of individual factors on the temperature at the thermal bridge location. The calculations showed that the variable X5, corresponding to the thickness of the internal insulation of the foundation wall [m], had the greatest individual impact among the analysed factors. The coefficient for this variable was 2,5673, meaning that a change from level -1 to +1 results in an increase in average temperature of approximately 5,13°C. The results obtained can serve as a valuable source of information for researchers, designers, engineers, and decision-makers, supporting effective decision-making at the building design stage for structures with heated usable spaces.
PL
W artykule przedstawiono aktualne wymagania i standardy dotyczące modelowania systemów elektroenergetycznych w kontekście integracji odnawialnych źródeł energii (OZE) z siecią. Omówiono europejskie regulacje, w szczególności kodeks sieci NC RfG, które nakładają obowiązek dostarczania i walidacji modeli symulacyjnych nowych jednostek wytwórczych. Autorzy analizują zarówno modele dostarczane przez producentów, jak i modele ogólne zgodne z normą IEC 61400-27-1, wskazując na ich zastosowanie w środowisku DIgSILENT PowerFactory. Podkreślono znaczenie iteracyjnego procesu modelowania, obejmującego testowanie, porównanie z danymi pomiarowymi i korektę parametrów, jako kluczowego elementu zapewnienia niezawodności i bezpieczeństwa pracy systemu elektroenergetycznego.
EN
The article presents the current requirements and standards for modelling power systems in the context of integrating renewable energy sources (RES) into the grid. The European regulations, and in particular the Network Code on Requirements for Grid Connection of Generators (NC RfG), are discussed which set out the obligation to provide and validate simulation models of new power generating modules. The authors analyse both models provided by manufacturers and general models compliant with IEC 61400-27-1, indicating their use in the DIgSILENT PowerFactory environment. The article emphasizes the importance of iterative modelling process, including testing, comparison with the measured data and parameter correction, as a key element to ensure reliable and safe operation of the electric power system.
PL
W artykule omówiono referaty przygotowane na sesję CIGRE 2024 w ramach Komitetu Studiów C2 Sterowanie i praca systemów elektroenergetycznych. Referaty i dyskusje prowadzone podczas Sesji skupiały się na tworzeniu odporności operacyjnej na zdarzenia ekstremalne i nieprzewidywalne, a także dotyczyły zmian w działaniu oraz sterowaniu systemem elektroenergetycznym w kontekście transformacji energetycznej.
EN
Papers discussed below have been prepared for the CIGRE 2024 session as part of the Study Committee C2 System Operation and Control. Presented papers and discussions took place during the session focused on issues concerning creating operational resilience to extreme/unpredictable events as well as changes on power system operation and control considering the energy transition.
EN
Special lighting effects, popularly known as “the miracles of light”, take place at the solstices or equinoxes in three medieval churches located in the Spanish city of Burgos and its surroundings. These hierophanies can be observed in religious buildings whose design and construction were carried out by medieval architects associated with what is known as “taller de los Colonia”. The underlying assumption of the research is that the same effects were also generated in the Conception Chapel of Burgos Cathedral and were visible until the Chapel of Santa Tecla was built in the 18th century. This paper virtually reproduces these lighting effects using solar simulation software tools and analyses the methods used to generate them.
PL
Specjalne efekty świetlne, popularnie zwane „cudami światła”, pojawiają się podczas przesileń lub równonocy w trzech średniowiecznych kościołach zlokalizowanych w hiszpańskim mieście Burgos i jego okolicach. Te hierofanie można zaobserwować w budynkach sakralnych, których projekt i konstrukcja zostały wykonane przez średniowiecznych architektów związanych z tak zwanym „taller de los Colonia”. Założeniem leżącym u podstaw badań jest to, że te same efekty zostały wygenerowane również w kaplicy Poczęcia NMP w katedrze w Burgos i były widoczne do czasu zbudowania kaplicy św. Tekli w XVIII w. W niniejszym artykule wirtualnie odtworzono te efekty świetlne przy użyciu oprogramowania do symulacji oświetlenia słonecznego i zanalizowano metody ich generowania. Ukryta historia katedry w Burgos (Hiszpania): wirtualna rekonstrukcja efektów świetlnych wygenerowanych w XV-wiecznej kaplicy Poczęcia NMP lub św. Anny
PL
Synteza octanu metylu metodą katalitycznej destylacji reaktywnej została zasymulowana przy użyciu oprogramowania Aspen Plus. Optymalne parametry to: liczba półek 43, podawanie kwasu octowego na 12. półkę, podawanie metanolu na 41. półkę, refluks 1,4, stosunek alkidów 1,1. Zastosowanie, w tych samych warunkach, jednowieżowego systemu destylacji reaktywnej umożliwiło znaczne zmniejszenie zużycia energii i inwestycji w sprzęt w porównaniu z systemem dwuwieżowym. Roczne średnie koszty produkcji były o 38,88% mniejsze niż w przypadku procesu dwuwieżowego
EN
Catalytic reactive distn. of AcOMe was simulated by using Aspen Plus software. The optimum theor. plate number was 43, the optimum AcOH feeding position was the 12thplate, the optimum MeOH feeding position was the 41st plate, the optimum reflux ratio was 1.4, and the optimum alkyd ratio was 1.1. Under basically the same conditions, use of the single-tower reactive distn. system can greatly reduce energy consumption and equipment investment when compared with the 2-tower system. The annual av. costs prodn. were by 38.88% lower than that of the 2-tower process.
PL
W artykule przedstawiono sposób implementacji protokołu IPv6 w sieci teleinformatycznej zbudowanej z wykorzystaniem sprzętowych urządzeń sieciowych, a także z wykorzystaniem oprogramowania umożliwiającego programowe uruchomienie mechanizmów wspierających działanie sieci z protokołem IPv6. Na bazie zbudowanej sieci, zobrazowano sposób konfiguracji szeregu usług sieciowych oraz użytkowych, które pozwoliły na realizację routingu dynamicznego IPv6, automatyczną konfigurację urządzeń końcowych pracujących w sieci IPv6, organizację systemu nazw domenowych IPv6, a także współpracę sieci IPv6 z siecią IPv4. Omówiono również wyniki testów pokazujących funkcjonowanie poszczególnych mechanizmów sieciowych.
EN
The paper shows how to implement IPv6 in a computer network built using hardware network devices, as well as using open source software to enable mechanisms to support the operation of networks with IPv6. On the basis of the built network, it was illustrated how to configure a number of network and user services that allowed the implementation of IPv6 routing, autoconfiguration of end devices operating in an IPv6 network, organization of the IPv6 domain name system, as well as the cooperation of an IPv6 network with an IPv4 network. The results of tests showing the functioning of the various network mechanisms are also discussed.
EN
Database selection in a measurement and control system is based on criteria that ensure system stability, reliability, data security, scalability, and lower infrastructure costs. Efficiency is also crucial, guaranteeing GUI responsiveness and enabling complex data analysis. A data management solution utilizing smartDSM middleware was outlined in the article. This Java-based software facilitates CRUD operations and easy database engine addition. Reflectivity-based modularity streamlines implementation. The solution's effectiveness is confirmed by test results.
PL
Wybór bazy danych w systemie pomiarowo-sterującym opiera się na kryteriach zapewniających stabilność, niezawodność, bezpieczeństwo danych, skalowalność i niższe koszty infrastruktury. Istotna jest również efektywność gwarantująca responsywność GUI i umożliwiająca złożoną analizę danych. W artykule przedstawiono rozwiązanie do zarządzania danymi z zastosowaniem middleware smartDSM. Jest to oprogramowanie w Javie, ułatwiające operacje CRUD i łatwego dodawania silników bazodanowych. Modularność oparta na mechanizmie refleksji usprawnia implementację. Skuteczność rozwiązania potwierdzają wyniki testów.
EN
Alarm systems are one of the parts of protection and security systems. In combination with other elements, it provides security for selected assets and contributes to their protection against various risks. The article deals with the description of the development and, at the same time, current trends in evaluating the effectiveness of alarm systems to point out the connection between methods and software tools.
PL
Systemy alarmowe są jednym z elementów systemów ochrony i bezpieczeństwa. W połączeniu z innymi elementami zapewnia bezpieczeństwo wybranym aktywom i przyczynia się do ich ochrony przed różnymi ryzykami. Artykuł dotyczy opisu rozwoju i jednocześnie aktualnych trendów w ocenie skuteczności systemów alarmowych w celu wskazania powiązań metod i narzędzi programowych.
18
Content available Electrodermal activity in polygraph testing
EN
Electrodermal Activity (EDA) is considered one of the most informative physiological responses to emotional stress, providing extensive data. This research is dedicated to investigating the measurement of EDA within the context of polygraph testing, utilizing the specialized LXSoftware. It includes a comprehensive analysis of EDA signal, with a particular emphasis on its correlation with various types of polygraph questions. Additionally, the study examines the characteristics of the EDA signal and factors that may potentially influence the measurements.
PL
Aktywność elektrodermalna (EDA) jest uważana za jedną z najbardziej informatywnych odpowiedzi fizjologicznych na stres emocjonalny, dostarczając obszernych danych. Niniejsze badanie poświęcone jest zbadaniu pomiaru EDA w kontekście testów poligraficznych, wykorzystując specjalistyczne oprogramowanie LXSoftware. Obejmuje ono kompleksową analizę oceny sygnału EDA, ze szczególnym uwzględnieniem jego korelacji z różnymi rodzajami pytań poligraficznych. Ponadto, badanie analizuje charakterystykę sygnału EDA oraz czynniki, które potencjalnie mogą wpływać na pomiary.
EN
The article presents research on the influence of initial conditions on the self-guidance of a guided bomb towards a stationary ground target. The aim of the study was to investigate the correlation between the initial tilt angle of the guided bomb and the precision of impact, as well as the time required to reach the surface target. To fulfil this purpose, the flight control system of the guided bomb needed to be designed accordingly. The need to develop these systems arises from emerging information that Ukraine and Israel are converting unguided bombs into precision-guided ones. This justification is based on objective reasons. The article analyses the application of classical controllers. PI, PD and PID. Their task was to accurately guide a stationary ground target under various initial conditions. A preliminary method has been proposed for selecting optimal gain coefficients for the PID controller, which constitutes the main component of the autopilot of the guided bomb flight control system. A proprietary interpolation method was suggested, starting with the use of an optimization function in MATLAB software. The numerical findings are presented in a graphical manner.
PL
W artykule przedstawiono wyniki badań określających wpływ warunków początkowych samonaprowadzania bomby kierowanej na nieruchomy cel naziemny. Skupiono się na analizie zależności początkowego kąta pochylenia bomby kierowanej na dokładność trafienia oraz czas potrzebny na dotarcie do celu naziemnego. W tym celu należało odpowiednio zaprojektować system sterowania lotem bomby kierowanej. Zasadność tych badań wynika między innymi z konieczności rozwoju tych systemów ze względu na pojawiające się informacje, że zarówno Ukraina, jak i Izrael przekształcają niekierowane bomby w ich precyzyjne odpowiedniki. W artykule poddano analizie zastosowanie regulatorów klasycznych: PI, PD oraz PID. Ich zadaniem było precyzyjne naprowadzanie na naziemny cel nieruchomy dla różnych warunków początkowych. Dodatkowo zaproponowana została wstępna metoda doboru optymalnych współczynników wzmocnień dla regulatora PID, stanowiącego główny element autopilota systemu sterowania lotem bomby kierowanej. Wyniki badań numerycznych zostały przedstawione w postaci graficznej.
PL
W artykule przedstawiono oryginalne wyniki badań empirycznych ukierunkowanych na zastosowanie modelowania informacji o budynku (ang. Building Information Modeling, BIM) w sektorze architektury oraz inżynierii i budownictwa (ang. Architecture, Engineering and Construction, AEC), a przede wszystkim na wykrywanie kolizji w modelu BIM. Badania te są częścią projektu finansowanego przez Unię Europejską. W pracy przedstawiono metodę badań, fazę eksperymentalną oraz wyniki. Testy przeprowadzono w pięciu programach do wykrywania kolizji. Porównanie wyników pod względem jakości informacji zwrotnej i ocena jej przydatności wnoszą nową wiedzę, która przyczynia się do zrównoważonego rozwoju budownictwa dzięki stosowaniu BIM.
EN
The article presents the original results of empirical research focused on application of Building Information Modeling (BIM) in the Architecture, Engineering and Construction (AEC) practices, specifically on detection of clashes in a BIM model. This research is part of the project founded by the European Union. The study presents methodology, experimental phase and findings. The tests were conducted in five clash detection programs. A comparison of the results in terms of the quality of the feedback, and an assessment of its usefulness contributes with new knowledge that enhances sustainability aspects of BIM.
first rewind previous Strona / 50 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.