Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 204

Liczba wyników na stronie
first rewind previous Strona / 11 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  measurement uncertainty
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 11 next fast forward last
EN
Fuel consumption measurement itself is a demanding process and it is difficult to determine the exact consumption of a vehicle. Fuel consumption can be determined in various ways. One way to determine consumption is through driving tests. We know several types of driving tests. Nowadays, most vehicles and all new vehicles can provide a wealth of data to the driver directly during vehicle operation. One of them is the data on the consumption of the vehicle also through the on-board computer located in the vehicle. The information provided to the driver may not reflect reality. In most cases, they are inaccurate and do not correspond to reality. Therefore, the subject of the research will be to verify the accuracy of the provided data on vehicle consumption by the on-board computer. The aim of the research will be to determine the extent to which consumption data are true. Vehicle consumption, as well as measurements are performed on one vehicle in every day traffic. This will ensure that it is possible to compare the measured data with each other.
EN
The article presents methodology for testing the electric strength of vacuum chambers designed for modern medium voltage switchgear developed by the authors, using two innovative test stands designed and constructed by the research team above. Verification of the correctness of operation of the test stands, as well as the validity of the developed methodology was carried out by performing a series of tests. It was determined that below certain pressure values in the tested chamber (from about 5:0 x 100 Pa for station 1 and for about 4:0 x 10-1 Pa for station 2), the electric strength maintains a constant value, which guarantees stable operation of the vacuum chamber. The values of the total measurement uncertainty for the electric strength tests were also estimated.
PL
W pracy analizie poddano wyniki badań przyczepności cementowych zapraw klejących do płytek ceramicznych wykonanych na zlecenie organów nadzoru budowlanego w latach 2016-2020. Znaczna ilość zbadanych cementowych zapraw klejących nie spełniła kryterium odbiorczego i zgodnie z regulacjami prawnymi ich producent zobowiązany był do niezwłocznego wycofania wyrobu z rynku. Przy ocenie zgodności wyników z kryteriami stosowana jest reguła prostej akceptacji, co oznacza, że wyrób został uznany za zgodny lub niezgodny w odniesieniu do wyniku, jeśli wynik ten, bez uwzględnienia zmienności wynikającej z niepewności pomiarowej, spełnił bądź nie spełnił wymagań progowych. Omówiono możliwe sytuacje, w których producent dokonał prawidłowej oceny i weryfikacji stałości właściwości użytkowych [AVCP] cementowej zaprawy klejącej, zaś ocena laboratorium była negatywna z powodu nie uwzględnienia zmienności wynikającej z niepewności pomiarowej lub specyfiki wieloetapowej metody badawczej. Analizę wyników badań przeprowadzono według podziału na cementowe zaprawy klejące klasy C1 i C2 oraz według podziału na laboratoria notyfikowane, w których wykonane zostały badania. Analizując proporcje pomiędzy wyrobami spełniającymi i niespełniającymi wymagań w dwóch laboratoriach wykonujących badania na zlecenie organów nadzoru budowlanego, stwierdzono duże różnice pomiędzy nimi.
EN
The paper analyzes the results of adhesion tests of cementitious adhesives to ceramic tiles, commissioned by construction supervision authorities in 2016-2020. A significant number of the tested cementitious adhesives did not meet the acceptance criteria. Following legal regulations, their manufacturer was obliged to withdraw the product from the market immediately. When assessing the compliance of the results with the requirements, the simple acceptance rule is applied. It means that the product is considered compliant only if the result met the threshold requirements. The results variability estimated from the measurement uncertainty is not taken under consideration. Possible situations in which the manufacturer correctly assessed and verified the constancy of performance [AVCP] of the cementitious adhesive, but the laboratory assessment was negative due to not including the variability resulting from measurement uncertainty, or the specificity of the multi-stage research methodology were discussed. The analysis of the test results was carried out according to the division into C1 and C2 class cementitious adhesives, and also according to the division into notified laboratories, where the tests were performed. When analyzing the number of products that meet or not the requirements, significant differences were found between laboratories carrying out tests commissioned by construction supervision authorities.
EN
Several use cases from the areas of manufacturing and process industry, require highly accurate sensor data. As sensors always have some degree of uncertainty, methods are needed to increase their reliability. The common approach is to regularly calibrate the devices to enable traceability according to national standards and Syst\`eme international (SI) units - which follows costly processes. However, sensor networks can also be represented as Cyber Physical Systems (CPS) and a single sensor can have a digital representation (Digital Twin) to use its data further on. To propagate uncertainty in a reliable way in the network, we present a system architecture to communicate measurement uncertainties in sensor networks utilizing the concept of Asset Administration Shells alongside methods from the domain of Organic Computing. The presented approach contains methods for uncertainty propagation as well as concepts from the Machine Learning domain that combine the need for an accurate uncertainty estimation. The mathematical description of the metrological uncertainty of fused or propagated values can be seen as a first step towards the development of a harmonized approach for uncertainty in distributed CPS in the context of Industrie 4.0. In this paper, we present basic use cases, conceptual ideas and an agenda of how to proceed further on.
5
Content available remote Szacowanie niepewności pomiarów współrzędnościowych na odległość
PL
W artykule przedstawiono propozycję ułatwiającą upowszechnienie szacowania niepewności pomiarów współrzędnościowych, a także ofertę świadczenia odpowiedniej usługi na odległość.
EN
The paper presents a proposal to facilitate the dissemination of estimating the uncertainty of coordinate measurements as well as an offer of a relevant distance service.
6
Content available remote Niepewność pomiaru w dokładnych pomiarach płaskości
PL
W artykule przedstawiono wynik badania niepewności pomiaru odchyłki płaskości za pomocą interferometru TOPOS. Do badań użyto płaskiego szkła interferencyjnego i płytki wzorcowej.
EN
The results of the measurement of the measurement uncertainty of flatness using the TOPOS interferometer are presented. Optical flat and gauge block were used for the tests.
PL
W artykule przedstawiono tematykę dotyczącą szacowania niepewności pomiaru mocy chwilowej w układzie do bezinwazyjnej diagnostyki łożysk tocznych, składającego się z przetworników: napięcia oraz prąd-napięcie. Zaprezentowano sposób oceny niepewności pomiarowej oraz przedstawiono przykładowe wyniki wykonanych analiz. Na tej podstawie sformułowano wnioski dotyczące dokładności pomiaru w układzie przeznaczonym do bezinwazyjnej diagnostyki łożysk tocznych w silnikach indukcyjnych.
EN
The article presents the problem concerning the estimation of uncertainty of measurement of the instantaneous power in a non-invasive rolling bearings diagnostic system, consisting of voltage and current-voltage transducers. The method of assessing measurement uncertainty as well as exemplary results of performed analyses are presented. On this basis, conclusions were drawn regarding the accuracy of the measurement system designed for non-invasive diagnosis of rolling bearings in induction motors.
EN
The objective of the paper is to analyse traceability issues in real-life gas flow measurements in complex distribution systems. The initial aim is to provide complete and traceable measurement results and calibration certificates of gas-flow meters, which correspond to specific installation conditions. Extensive work has been done to enable a more credible decision on how to deal in particular situations with the measurement uncertainty which is always subject of a flow meter’s calibration as a quantitative parameter value obtained in laboratory, and with the qualitative statement about the error of an outdoor meter. The laboratory simulation of a complex, real-life distributed system has been designed to achieve the initial aim. As an extension of standardized procedures that refer to the laboratory conditions, the proposed methods introduce additional “installation-specific” error sources. These sources could be either corrected (if identified) or considered as an additional “installation-specific” uncertainty contribution otherwise. The analysis and the results of the experimental work will contribute to more precise and accurate measurement results, thus assuring proper measurements with a known/estimated uncertainty for a specific gas flow installation. Also, the analysis will improve the existing normative documents by here presented findings, as well as fair trade in one of the most important and growing energy consumption areas regarding the legal metrology aspects. These facts will enable comparing the entire quantity of gas at the input of a complex distributed system with the cumulative sum of all individual gas meters in a specific installation.
9
Content available remote Outsourcing in estimating the uncertainty of coordinate measurements
EN
The current situation in the estimation of uncertainty of coordinate measurements and the proposal to perform the uncertainty estimation service by an external institution are presented. This possibility arose thanks to the development of a method that uses the current calibration results as input information about the accuracy of the measuring machine, and as the information about the dimensions of the object – the coordinates of a small number of so-called characteristic points.
PL
Przedstawiono aktualną sytuację w zakresie szacowania niepewności pomiarów współrzędnościowych oraz propozycję wykonania usługi szacowania niepewności przez instytucję zewnętrzną. Ta możliwość pojawiła się dzięki opracowaniu metody, która jako informacji wejściowej o dokładności maszyny pomiarowej używa aktualnych wyników wzorcowania, a jako informacji o wymiarach przedmiotu – współrzędnych niewielkiej liczby tzw. punktów charakterystycznych.
PL
W artykule podjęto próbę analizy rodzajów i skutków wad (FMEA – Failure Mode and Effects Analysis) podczas badań fizycznych cementu powszechnego użytku wykonywanych zgodnie z wytycznymi serii norm PN-EN 196. Umożliwiła ona wytypowanie obszarów o wysokim stopniu ryzyka, na etapie których wystąpienie błędu dało podstawy do podważenia wyniku oznaczenia. Ponadto pozwoliła zaszeregować błędy w zależności od ich znaczenia, co może ułatwić zaplanowanie odpowiednich działań zapobiegawczych i określić ich przewidywaną skuteczność. Kompleksowo przeprowadzona analiza może stanowić metodę sterowania jakością i zarządzania ryzykiem, a także podstawę systematycznej identyfikacji wielu zagrożeń przy uwzględnieniu poziomu ryzyka. Może przyczynić się to do poprawy jakości wykonywanych badań, zmniejszenia liczby reklamacji, a także pozwolić na lepsze dostosowanie się do wymagań klienta. Na jej podstawie możliwe będzie także wprowadzenie pewnych standardów pracy zespołu laborantów, które pozwolą zapewnić możliwie najwyższą ochronę przed przypadkowymi pomyłkami.
EN
The article attempts to analyse the types and effects of failures (FMEA – Failure Mode and Effects Analysis) during physical tests of common cement performed in accordance with the PN-EN 196 series of standards. FMEA enabled the identification of areas of high degree of risk, at the stage where the occurrence of an error gave the base to the undermining the test result. In addition, it allowed to classify errors depending on their importance, which may be helpful to plan appropriate preventive actions and determine their expected effectiveness. Comprehensive analysis can be a method of quality control and management of risk, as well as a basis for systematic identification of many threats taking into account the level of risk. This will help to improve the quality of the performed tests, to reduce the number of complaints, and also allows for better adaptation to the customer's expectations. On the basis of FMEA, it might also be possible to introduce some better standards for the work of a laboratory team that will ensure the highest possible protection against accidental mistakes.
PL
Właściwie wdrożone doskonalenie pozwala osiągnąć założone cele, zwiększyć skuteczność systemu zarządzania oraz potwierdzić spójne działania laboratorium.
EN
A comparative analysis of the measurement uncertainty estimation result is carried out. The results are obtained by GUM method described in the Guide to the expression of uncertainty in measurement, as well as by Monte-Carlo method recommended in Supplement 1 to the Guide. Examples of calculations of uncertainty of relative error for electromagnetic flow meters calibration by two methods are given. The features of application, advantages and disadvantages of these methods are described.
PL
W pracy omówiono analizę porównawczą wyniku oszacowania niepewności pomiaru. Wyniki uzyskano metodą GUM, opisaną w przewodniku do wyrażania niepewności pomiaru, a także metodą Monte-Carlo zalecaną w Suplemencie 1 do tego przewodnika. Podano przykłady obliczeń niepewności błędu względnego dla kalibracji przepływomierzy elektromagnetycznych za pomocą dwóch metod. W artykule opisano cechy zastosowaia, w tym: zalety oraz wady tych metod.
EN
Laser Tracking systems are commonly used in all branches of industry, which requires accurate large-scale measurements for instance aviation, space and shipbuilding industries. Laser Trackers belong to the group of non-Cartesian Coordinate Measuring Systems. Determination of the measured point coordinates involves the measurements of distance using laser beam and two angles recorded by horizontal and vertical encoders. Additionally, the environmental conditions are monitored and used for compensation of measured distance. The coordinates of single measured point are estimated using the results obtained from a series of samples taken in a short time period. The average value obtained from a sample is given as a result; additionally, the dispersion parameters are calculated which can be used to evaluate the probing process. This paper presents the research procedure which allows assessing the influence of chosen dispersion parameter related to the sample averaging on accuracy of the measurements performed with laser tracking devices. The procedure involves standard elements measurements during which the points with similar level of RMS parameter are used for the calculation of the measurement result. Such approach allows simulating the increasing dispersion of points taken into account during sample probing. The results presented in the article can be helpful to the operators of laser tracking systems to assess the influence of the probing process on the measurement accuracy.
PL
W artykule przedstawiono zagadnienie dotyczące wykorzystania przyrządu wirtualnego do szacowania niepewności pomiaru mocy chwilowej. Analiza dotyczy układu do diagnostyki łożysk tocznych, składającego się z przetworników: napięcia oraz prąd-napięcie, który wykorzystano do badań diagnostycznych łożysk silników indukcyjnych metodą, opartą na pomiarze i analizie sygnałów napięcia i prądu pobieranych przez maszynę. Zaprezentowano opracowany do celów szacowania niepewności pomiaru mocy chwilowej przyrząd wirtualny, który do wyznaczania niepewności metodą Typu A wykorzystuje jakobiany macierzy, natomiast do obliczenia niepewności metodą Typu B używa danych, dotyczących dokładności karty akwizycji danych i przetworników. Dokonano także sprawdzenia poprawności działania przyrządu wirtualnego, przedstawiono przykładowe wyniki analiz i porównano je z rezultatami obliczeń wykonanymi przy wykorzystaniu arkusza kalkulacyjnego MS Excel.
EN
The paper presents the issue of the use of a virtual device to estimate the uncertainty of a system for rolling bearing diagnostics using a research method based on measuring and analysing the instantaneous power signal consumed by an induction motor. The virtual instrument developed for the purpose of estimating the uncertainty of instantaneous power measurement has been used to estimate the uncertainty of Type A instantaneous power measurement using Jakobian matrix, while to calculate the uncertainty of Type B uses the data on the accuracy of instruments used, given by their manufacturers. For comparison, calculations of uncertainty of instantaneous power measurement were also made using the MS Excel spreadsheet. In both cases, the obtained results were identical. In the case under consideration, the result of instantaneous power measurement, with a voltage of 236.54 V and a current value of 3.03 A, can be represented as: p = (716.72 ± 34.44) VA. The developed virtual instrument can be used to estimate the uncertainty of measurement of other physical quantities, e.g. temperature or pressure.
15
Content available remote Modułowe narzędzia pomiarowe
PL
W pracy opisano narzędzia Multimar firmy Mahr. Opisano zalety zastosowania modułowej budowy urządzeń w stosunku do uniwersalnych narzędzi pomiarowych. Pokazano możliwość wykorzystania przyrządów do nietypowych zadań pomiarowych. Wskazano na możliwość ograniczenia inwestowanych środków w przypadku wyboru przyrządów modułowych w porównaniu z uniwersalnym sprzętem pomiarowym. Dokonano porównania niepewności pomiaru uzyskiwanych w przypadku wykorzystania przyrządu modułowego Multimar 25 EWR w porównaniu z uniwersalnymi narzędziami pomiarowymi.
EN
In a paper Mahr’s Multimar measuring tools has been described. Advantages of using modular construction of devices in relation to universal measuring tools have been presented. The possibility of using instruments for a typical measurement tasks has been shown. The possibility of limiting invested funds in the case of choosing modular devices in comparison with universal measuring equipment was indicated. The comparison of measurement uncertainty obtained when using the Multimar 25 EWR modular instrument was compared to universal measuring tools.
PL
Systemy umożliwiające lokalizację obiektu zdobywają coraz większą popularność. Kilka lat temu jedynym ogólnodostępnym systemem lokalizacyjnym był amerykański Navstar GPS, który niestety nie pracował w pomieszczeniach zamkniętych takich jak magazyny, czy hale produkcyjne. Postęp technologiczny i miniaturyzacja sprawiły, że systemy lokalizacyjne wkroczyły w nowy obszar. W artykule zaprezentowano wyniki testów precyzji i dokładności lokalizacji obiektów z użyciem systemu lokalizacji wewnątrzbudynkowej Dimension4 firmy Ubisense.
EN
Systems enabling the location of objects are gaining more and more popularity. A few years back, only the American localization system Navstar GPS has been available for commercial use. Unfortunately, this system does not perform well in enclosed spaces such as buildings, warehouses or production halls. Technological progress and miniaturization possibilities have made the localization systems enter the previously unavailable area. In this paper tests for determining the precision and accuracy of the Ubisense Dimension4 indoor location system are presented.
17
Content available remote Systematic measurement errors of local B-coils due to holes
EN
B-coils (search coils) for measurement of local value of flux density B are made by drilling holes in the sample under test. The holes are non-magnetic discontinuities and distort the B distribution. The FEM analysis and experimental results presented in this paper show that in the first approximation the measurement errors are proportional to the ratio of hole diameter to coil width. For example, for a 10 mm wide B-coil made with 1 mm holes the error can be around 10%. Hence, in order to achieve errors less than 1% the hole diameter should be less than 1% of the coil width.
PL
Cewki do pomiaru lokalnej wartości indukcji magnetycznej B są wykonane przez wiercenie otworów w testowanej próbce. Otwory te reprezentują niemagnetyczne nieciągłości i powodują zniekształcenie dystrybucji B. Wyniki analizy FEM i pomiarów zaprezentowane w artykuly wykazują że w pierwszym przybliżeniu błędy pomiarowe są proporcjonalne do stosunku średnicy otworów do szerokości cewki. Np. dla cewki o szerokości 10 mm i otworach 1 mm błąd może być ok. 10%. Dlatego też, aby uzyskać błąd mniejszy niż 1% to średnica otworu powinna być mniejsza niż 1% szerokości cewki pomiarowej B.
PL
W artykule przedstawiono metodę wzorcowania stanowisk z kontrolnymi zbiornikami dzwonowymi, opartą na zastosowaniu dysz Venturiego o przepływie krytycznym, jako wzorców pośredniczących. Zaproponowana metoda pozwala na wzorcowanie dawek pomiarowych o objętości od ok. 5 dm3, z niepewnością mniejszą niż 0,2 %.
PL
Przedstawiono najważniejsze czynniki wpływające na uzyskiwanie wiarygodnych wyników pomiarów struktury geometrycznej powierzchni. Omówiono zasady doboru metody pomiarowej, dostosowanej do charakteru mierzonej powierzchni i cech poszczególnych przyrządów pomiarowych – ich zalet, wad i ograniczeń. Podano zasady dobrej praktyki metrologicznej podczas przygotowywania przyrządu do pomiarów oraz sposób prawidłowego prowadzenia analizy otrzymanych wyników pomiaru w celu obliczenia parametrów struktury geometrycznej powierzchni.
EN
The most important factors influencing obtaining reliable results of surface structure measurements are presented. The article presents the rules for the selection of an appropriate measurement method adapted to the nature of the measured surface and the advantages, disadvantages and limitations of measuring instruments. Principles of good metrological practice during the preparation of the device for carrying out measurements and performing the analysis in order to calculate the parameters of the of the surface structure were discussed.
20
Content available remote Szacowanie niepewności pomiaru parametrów profilu metodą Monte Carlo
PL
Przedstawiono zalety zastosowania metody Monte Carlo do szacowania niepewności pomiaru parametrów amplitudowych profilu pierwotnego, otrzymanego na podstawie pomiarów struktury geometrycznej powierzchni.
EN
The advantages of the Monte Carlo method for estimating the uncertainty of measurement of the amplitude parameters of the primary profile determined during the measurements of the surface texture are presented.
first rewind previous Strona / 11 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.