The problem of water renewal in swimming pools is mainly related to the concentration of some contaminants (with the quality of swimming pool water) and to the need for water to supplement losses in the closed swimming pool circuit (volume of swimming pool water). This problem is presented on the basis of physicochemical analysis of pool water samples (taken every two hours during one day and taken daily during one week) and the amount of supplementary water demand (water metre reading) depending on attendance and in relation to rational water management for a sports-type pool. The results were compared with the guidelines of the Swimming Pool Water Quality Decree and the recommendations of DIN 19643. Pool water quality parameters, such as: absorbance, redox potential, combined chlorine, nitrates, and chlorides, could be considered as indicative for the daily assessment of water, and depending on their value, supplement the circuit with water from the water supply network. The amount of supplementary water used (an average of 40.6 L/bather day) exceeded the DIN 19643 recommendations by 26%. To rationalise water management, a water quality analysis should be carried out with the consumption of supplementary water reduced to 30 L/bather day (that is, on average 11.5 m3/day instead of 15.6 m3/day).
PL
Problem odnowy wody w obiektach basenowych związany jest przede wszystkim z zatężaniem niektórych zanieczyszczeń (z jakością wody basenowej) oraz z zapotrzebowaniem na wodę uzupełniającą straty w zamkniętym obiegu basenowym (objętością wody basenowej). Problem ten przedstawiono na podstawie analizy fizykochemicznej próbek wody basenowej (pobranych co dwie godziny w ciągu jednego dnia oraz pobranych codziennie w ciągu jednego tygodnia) i wielkości zapotrzebowania na wodę uzupełniającą (rejestr wskazań z wodomierza) w zależności od frekwencji oraz w odniesieniu do racjonalnej gospodarki wodnej dla basenu typu sportowego. Wyniki porównano z wytycznymi rozporządzenia w sprawie jakości wody w pływalniach oraz zaleceniami normy DIN 19643. Parametry jakości wody basenowej, takie jak: absorbancja, potencjał redox, chlor związany, azotany i chlorki, można było uznać za wskaźnikowe do codziennej oceny jej jakości i w zależności od ich wartości uzupełniać obieg wodą z sieci wodociągowej. Stosowana ilość wody uzupełniającej (średnio 40,6 L/os.·d) przekraczała zalecenia normy DIN 19643 o 26%. W celu racjonalizacji gospodarowania wodą należałoby przeprowadzać analizę jakości wody przy zmniejszonym do 30 dm3/os.·d zużyciu wody uzupełniającej (czyli średnio 11,5 m3/d zamiast 15,6 m3/d).
Stosowane układy oczyszczania wody basenowej mają na celu przygotowanie bezpiecznej wody zapewniającej komfortowe warunki dla pływaków. Ważnym elementem w pływalniach krytych jest również wentylacja, dzięki której odbierane są zyski wilgoci oraz dostarczane jest powietrze świeże zapewniające właściwą jakość powietrza. W artykule przedstawiono wyniki badań parametrów wody i powietrza w basenach zlokalizowanych w dwóch krajach - Polsce i Stanach Zjednoczonych. Przeanalizowano różnice konstrukcyjne basenów, rozwiązania układu wentylacji i procesu uzdatniania wody oraz sposobu użytkowania basenu pod kontem ich wpływu na jakość wody i powietrza wewnętrznego. Stosowane w Polsce i USA systemy uzdatniania wody basenowej są bardzo podobne. Główna różnica występuje w utrzymywanych parametrach jakości wody basenowej szczególnie stężenia chloru wolnego. W polskich basenach utrzymywano stężenie chloru wolnego na poziomie ok. 0,5 mgCI2/L, podczas gdy w basenach amerykańskich było ono wyższe 4-5 razy i wynosiło 1,9 -2,8 mg CI2/L Wynika to przede wszystkim ze stosowanych norm i przepisów w każdym z krajów. Różnica w stężeniach chloru wolnego w wodzie znalazła odzwierciedlenie w jakości powietrza, gdyż na basenach amerykańskich stwierdzono w nim aż 15-krotnie wyższe stężenia chloroaminy niż w basenach polskich, pomimo zapewnienia prawidłowej wentylacji utrzymującej wilgotność na wymaganym poziomie do 60%. Średnie stężenie chloroaminy odnotowane w powietrzu hali basenowej w USA wynosi aż 459 ±268 u.gCl2/L co jest wartością niższą niż zalecane przez WHO 500 u.gCI2/L, jednakże w pewnych okresach stężenie to było znacząco przekroczone.
EN
Swimming pool water purification systems are designed to prepare safe water that ensures comfortable conditions for swimmers. Ventilation is also an important element in indoor swimming pools, thanks to which moisture gains are removed and fresh air is supplied to ensure proper air quality. The article presents the results of research on water and air parameters in swimming pools located in two countries-Poland and the United States. The design differences of the swimming pools, the ventilation system, and the water treatment process, as well as the method of use of the swimming pool, were analyzed in terms of their impact on the quality of water and the indoor air. The swimming pool water treatment systems used in Poland and the United States are very similar. The main difference occurs in the maintained swimming pool water quality parameters, especially the concentration of free chlorine. In Polish swimming pools, free chlorine was maintained at a level of approximately 0.5 mg CI22/L, while in American swimming pools it was 4-5times higher and reached 1,9-2,8 mgCI2/L. This is mainly due to the standards and regulations used in each country. The difference in free chlorine concentrations in water was reflected in air quality; as in American swimming pools, chloramine concentrations were found to be 15 times higher than in Polish swimming pools, despite adequate ventilation maintaining humidity at the required level of up to 60%. Chloramine concentrations recorded in air in the US are as high as 459 ±268 pg CL2/L, which is less than the 500ngC2/L recommended by the WHO. However, an average value at such a high level indicates that in certain periods the concentration was significantly exceeded.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono analizę numeryczną istniejącego basenu. Analiza obejmowała trzy warianty obciążeniowe związane z jego modernizacją. Pierwszy przypadek obciążeń dotyczył rzeczywistej pracy basenu przed modernizacją. Natomiast dwa kolejne przypadki obciążeń obejmowały możliwe oddziaływania na basen po modernizacji. W wyniku przeprowadzonych analiz stwierdzono, że modernizacja basenu związana ze zmianą jego obciążenia, nie spowoduje przekroczenia jego stanów granicznych.
EN
The article presents the numerical analysis of the existing swimming pool. The analysis included three load variants related to the pool modernization. The first load case was related to the actual operation of the pool before its modernization. Next, two subsequent load cases included possible impacts on the swimming pool after its modernization. As a result of the conducted analyzes, it was found that the modernization of the swimming pool will not result in exceeding its limit states.
Miejsca publiczne, takie jak strefy wellness czy baseny, zwykle przyciągają klientów wysoką jakością zastosowanych rozwiązań i najwyższym poziomem designu. Znajdujące się w nich nowoczesne łazienki powinny być wizytówką tych obiektów, miarą panującego w nich komfortu i luksusu. Dbałość o jakość powinna znajdować odzwierciedlenie nie tylko w drogich kafelkach czy efektownej ceramice łazienkowej, ale również w najmniejszych detalach, takich jak systemy odprowadzania wody.
Utrzymanie parametrów jakościowych wody basenowej wymaga stosowania odpowiednich procesów jednostkowych przy jednoczesnym przestrzeganiu norm prawnych. W artykule zawarto charakterystykę jakości wody w różnych nieckach basenowych oraz analizę badań wyników laboratoryjnych w oparciu o normy prawne. Zarejestrowane pomiary miały na celu porównanie efektywności systemów technologicznych uzdatniania wody wykorzystywanych w omawianym obiekcie. Przeprowadzono ocenę dezynfekcji wody basenowej w brodziku, basenie rekreacyjnym i sportowym oraz w wannach z hydromasażem – jacuzzi. Skuteczność dezynfekcji oceniono w oparciu o pomiary, tj. redox, stężenie chloru wolnego i związanego oraz poziom utlenialności.
EN
To maintain the quality parameters of swimming pool water it is necessary to apply adequate unit processes as well as compliance with the legal standards. In this paper there was discussed the water quality performance in different pool basin and there were analyzed the results of laboratory tests based on legal standards. The recorded measurements aimed to compare the yield of technology systems of swimming pool water treatment in a paddling pool, recreation pool, sport pool and hot tub – jacuzzi. The efficacy of water treatment was assessed by the results of measurements, i.e. redox, free and bound chlorine level and oxidisability level.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono badania jakości mikrobiologicznej powietrza wewnętrznego pływalni miejskiej. Scharakteryzowano biologiczne zanieczyszczenia powietrza określane jako bioaerozole, ich źródła oraz wpływ na życie i zdrowie ludzi. Ponadto omówiono propozycje zalecanych wskaźników mikrobiologicznych wykorzystywanych do oceny zanieczyszczeń powietrza oraz metodę zderzeniową poboru próbek do badań. Podano również zalecenia dotyczące zapewnienia bezpieczeństwa sanitarnego powietrza wewnętrznego w obiektach wykorzystywanych w celach sportowo-rekreacyjnych. W badanym powietrzu pływalni liczebności oznaczanych bakterii (mezofilnych, gronkowców oraz grzybów pleśniowych) były charakterystyczne dla powietrza niezanieczyszczonego. Jedynie liczba bakterii hemolizujących (głównie w pomieszczeniach przebieralni) uznawanych za potencjalnie chorobotwórcze nie spełniała tych kryteriów. Wśród gronkowców zidentyfikowano gatunki (Staphylococcus capitis, S. cohnii, S. auricularis i S. hominis), które ze złuszczającym się naskórkiem i wydzielinami organizmu przedostają się do powietrza i mogą być przyczyną różnych infekcji. Powietrze atmosferyczne przed budynkiem charakteryzowało się mniejszymi liczebnościami bakterii niż powietrze wewnętrzne co może świadczyć o istnieniu wewnętrznych źródeł emisji bioaerozoli. W związku z brakiem uregulowań prawnych i kryteriów dotyczących oceny jakości mikrobiologicznej powietrza na pływalniach, wskazany jest okresowy monitoring tego środowiska w celu wyeliminowania zagrożenia biologicznego i zapewnienia bezpieczeństwa sanitarnego użytkownikom tego typu obiektów.
EN
This paper presents a study of the microbiological quality of indoor air in a municipal swimming pool. Biological air pollutants known as bioaerosols were characterised, along with their sources and their impact on human life and health. Furthermore, proposals for recommended microbiological indicators used to assess air pollution as well as the impact method of sampling for research have been discussed. Recommendations were also given on how to ensure the sanitary safety of indoor air in facilities used for sports and recreation. In the examined air of the swimming pool, the numbers of bacteria (mesophilic bacteria, staphylococci and moulds) were characteristic of unpolluted air quality. Only the number of haemolytic bacteria (mainly in changing rooms) regarded as potentially pathogenic did not fulfil the criteria. Among the staphylococci, species (Staphylococcus capitis, S. cohnii, S. auricularis and S. hominis) were identified which, with exfoliating epidermis and body secretions, enter the air and may cause various infections. The ambient air in front of the building was characterised by lower bacterial counts than the indoor air, which may indicate the existence of internal sources of bioaerosol emissions. In the absence of legal regulations as well as criteria for microbiological air quality assessment in swimming pools, periodic monitoring of this environment is advisable to eliminate biological hazard and ensure sanitary safety for users of such facilities.
This paper presents technological innovations based on new hydraulic insulating materials, the use of which in reservoir construction will essentially reduce construction costs by up to half. New polymer-mineral based waterproofing materials N1 and PMM can be used to construct inexpensive reservoirs. In particular, a thoroughly mixed mixture of soil taken from the bottom of a reservoir or other substrate with PMM material at a ratio of 30 grams PMM to one kg of the substrate, laid on the bottom of the reservoir with a thickness of at least 10 cm, and tamped down to a layer of 7 cm or less, will withstand at least 2.5-3 atm pressure of water column. A similar result can be obtained if a 5 cm thick layer of N1 material is laid on the reservoir bottom, together with pebbles to reduce the cost of the proposed solution.
Opracowano koncepcję architektoniczną obiektu pływalni miejskiej z dwoma wariantami konstrukcji przekrycia w postaci powłoki walcowej. Przeprowadzono analizę porównawczą sił wewnętrznych w powłoce uzyskanych metodą numeryczną i analityczną. Zwymiarowano żelbetową konstrukcję przekrycia powłokowego zgodnie z obowiązującymi eurokodami.
EN
The architectural and construction concept of the swimming pool with two types of cylindrical shell roof was designed. A comparative analysis of internal forces using a numerical and analytical method has been carried out. The reinforced structure of cylindrical shell roof has been designed according to required eurocodes.
Using additives with water absorbing characteristics enables us to increase the amount of water in natural basins and significantly decrease the amount of water for agricultural usage. Despite various additives already existing, they are yet to be commonly used due to high cost price, complex technology, toxic impact and instability in biological and atmospheric conditions. However, the «Natlen» composite, which is a naturally based additive, is ecologically safe. It has a long shelf life, is cheap and provides high antifiltering rates. The composite is eruptive with dispersity of any type and is jelly when boosted. In an antifiltering layer it never cracks under static and dynamic influences. It has no seam and is resistant to aggressive liquids. It is ecologically safe. «Natlen» composite is recommended for building water basins in pastures, where it can particularly be used to satisfy the demand for drinking water for cattle.
11
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Surface water of Kébir Rhumel basin is indispensable for domestic and industrial needs of this region. Industrial development, with water excessive use and chemical products, in production and industrial treatment, and not sustainable fertilizers in agriculture, constitutes a serious threat to maintain our resources of good water quality. The majority of domestic and industrial wastewaters of the region, discharged to the stream water of Kébir Rhumel basin, promote the water enrichment in nutritious elements, phosphorus and nitrogen and particularly, the resulting increase in the aquatic primary production, mainly the planktonic or benthic algae. As a result, the physical and chemical properties of water deteriorate. This basin allows construction of the largest dam in Algeria “Beni-Haroun dam”. The infrastructure that was one of the greatest challenges of Algeria is now a reality. Hydraulic complex of Beni-Haroun remains a strategic and major achievement in the development program of water resources sector. This enormous building was constructed in the territory of the Wilaya (province) of Mila, used to meet water needs, with four million inhabitants, of eastern Algeria and other neighbouring regions that have suffered from lack of water consumption, especially in summer. In addition, it will irrigate over 42 000 ha, going thus to the several plains. Integration of sociological and environmental concerns into dams design is a recent phenomenon. It is considered at the impact study level, during which the dam study project is accompanied by a survey to assess project impact on natural environment and socioeconomic development.
PL
Wody powierzchniowe na terenie basenu Kébir-Rhumel są niezbędne do zaspokojenia domowych i przemysłowych potrzeb regionu. Rozwój przemysłowy z jego nadmiernym zużyciem wody i substancji chemicznych w procesie produkcji i przetwarzania oraz niezrównoważone stosowanie nawozów w rolnictwie stwarzają poważne zagrożenie dla jakości wody. Większość domowych i przemysłowych ścieków z regionu jest odprowadzana do wód płynących basenu Kébir-Rhumel, powodując ich wzbogacenie w pierwiastki biogenne (fosfor i azot), co skutkuje zwiększoną produkcją pierwotną głównie planktonowych i osiadłych glonów. W wyniku tego pogarsza się jakość wody. Układ basenu umożliwił zbudowanie największej zapory w Algierii – zapory Beni-Haroun. Ten obiekt infrastruktury wodnej, będący jednym z największych wyzwań Algierii, stał się rzeczywistością. Kompleks wodny Beni-Haroun jest strategiczym i głównym osiągnięciem programu rozwoju zasobów wodnych. Ta ogromna budowla umieszczona w prowincji Mila zaspokaja potrzeby 4 mln mieszkańców wschodniej Algierii i sąsiadujących regionów, które cierpiały na brak wody pitnej, szczególnie latem. Ponadto wodą ze zbiornika będzie się nawadniać 42 000 ha na kilku równinach. Zagadnieniem ostatnio branym pod uwagę podczas projektowania zapór jest integrowanie problemów społecznych i środowiskowych. Te problemy są rozważane na etapie oceny oddziaływania na środowisko, w którym projektowaniu zapory towarzyszy analiza wpływu projektu na środowisko naturalne i rozwój społeczno-gospodarczy.
13
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł przedstawia technologie filtracji wody basenowej za pomocą złoża AFM®. Wskazuje zalety tej nowoczesnej technologii w zakresie uzyskania odpowiednio czystej wody oraz redukcji kosztów wielu działań koniecznych do zachowania obiektu basenowego w wymaganym stanie.
EN
The author of the article presents technologies of pool water filtration using the AFM® filter media. It indicates the advantages of this modern technology in terms of ensuring clear water and reducing the costs of many activities necessary to maintain swimming pools in the required condition.
14
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and the possibility of reuse of washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of washings drainage into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of washings from the analysed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. Washings were subjected to sedimentation and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
15
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono analizę zapotrzebowania na energię szpitali oraz basenów w Polsce. Celem pracy było oszacowanie zużycia energii elektrycznej oraz ciepła w tych obiektach oraz oszacowanie wartości tego rynku dla potencjalnych dostawców urządzeń do indywidualnej produkcji energii w tych obiektach. Obecnie nie istnieje baza danych statystycznych, która obrazowałaby potrzeby energetyczne szpitali i basenów w Polsce. Obiekty te są szczególnie atrakcyjne dla jednostek kogeneracji, ponieważ charakteryzują się one stosunkowo dużym i stabilnym zapotrzebowaniem na energię elektryczną oraz ciepło, a w przypadku szpitali często również na parę technologiczną. W artykule przedstawiono przyjętą metodologię oszacowania zapotrzebowania na energię tych obiektów oraz zestawiono dane o zużyciu energii w wybranych szpitalach i basenach w Polsce. Dane te posłużyły do wyznaczenia jednostkowych wskaźników, wykorzystanych do oszacowania zapotrzebowania na energię szpitali i basenów w kraju.
EN
In the article analysis of the energy demand of hospitals and swimming pools in Poland was presented. The purpose of the work was to estimate at the country level the consumption of electricity and heat in these facilities and to estimate the value of this market for potential suppliers of cogeneration units to these facilities. Currently, there is no statistical database that would indicate the energy needs of hospitals and swimming pools in Poland. These facilities are attractive especially for cogeneration units, because they are characterized by a relatively large and stable demand for two forms of energy: electricity and heat, in the case of hospitals also for process steam. The article presents the adopted methodology for calculating the energy demand of these facilities and real data from selected hospitals and swimming pools in Poland, which were used to calculate the energy demand of all hospitals and pools in the country.
W artykule opisano obiekt basenowy, w którym w czterech instalacjach nie zostały spełnione wymagania dotyczące zawartości chloru związanego. Przeprowadzone kontrolne badania bakteriologiczne zdyskwalifikowały wodę we wszystkich obiegach przeznaczonych dla osób kąpiących się. Podejmowano różne działania naprawcze, m.in. zwiększenie częstotliwości płukania filtrów z ich przechlorowaniem. Jednak dopiero wykorzystanie układu mobilnego ozonowania z wprowadzeniem wody wysoko ozonowanej przed filtracją i płukanie instalacji cyrkulacyjnej zbiorników pozwoliło na likwidację zagrożenia bakteriologicznego oraz utrzymanie zawartości chloru związanego na poziomie wymaganym przez przepisy, tj. poniżej 0,3 mg Cl2/dm.
EN
In the analyzed facility, I fail to meet the requirements for four pool water installations analyzing chlorine level. The bacteriological control tests disqualified the water in all circulation installations. The service staff take various corrective actions like an increased frequency of filter rinsing with their overhauling and other repair methods offered by the market. Only the use of a mobile ozonation system, introduction highly ozonized water before filtration and rinsing of the tank circulation system allows eliminating the bacteriological threat and maintaining the chlorine content at a level below 0,3 mg Cl2/dm.
W artykule przedstawiono wybrane elementy zadania badawczego zrealizowanego w ramach projektu „OHT Inteligentny Optymalizator HVAC w funkcji potencjału tworzenia THM na basenach krytych – nowa metoda zarządzania energią elektryczną i ciepłem dopasowująca na bieżąco sterowanie wentylacją, ogrzewaniem, chłodzeniem (HVAC) do stężeń rakotwórczych chlorowcopochodnych metanu takich jak trihalometany (THM) oraz ich usuwania z basenów krytych. Program Operacyjny Inteligentny Rozwój 2014 – 2020”. Autorzy skupili się na przedstawieniu projektu naczynia analitycznego do odwzorowania w małej skali obiegu wody basenowej z wyłączeniem układu filtracji i dezynfekcji.
EN
The article presents selected elements of the research task realized within the project „OHT Intelligent HVAC Optimizer as a function of the THM potential for indoor swimming pools – a new method of electricity and heat management that adjusts ventilation, heating and cooling control (HVAC) to carcinogenic chlorogenic hydrocarbon concentrations such as like THMs and their removal from indoor pools. Operational Program Intelligent Development 2014 – 2020”. The authors focused on presenting the design of an analytical system for reproduction of the pool water circulation in a small scale, excluding the filtration and disinfection system.
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
PL
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The necessity of reducing the operating costs of swimming pools leads to attempts to reuse of backwash water from washing swimming pool filter beds. Their use for watering plants, sprinkling tennis courts and play fields, draining to nearby watercourses or even returning to swimming pool installations is taken into consideration. Current researches proved the toxicity of these waste streams. The results of these studies raise doubts about the rightness of the attempts to introduce washings from pool filters directly into the environment. The aim of the presented work is to determine the source of toxicity of filter backwash water. The assessed in the work washings were characterized by high turbidity, high content of both suspended solids and organic compounds. A decrease in value of general impurity indicators after the filtration process of washings has been shown, suggesting that the main source of toxicity may be the suspension, including various anthropogenic organic micropollutants. Although this is just a research hypothesis. For this reason, comparative studies on the occurrence of toxic organic micropollutants in raw filter backwash water, supernatant water and filtrate collected after the filtration process were carried out.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.