Artykuł omawia specyfikę membran paroprzepuszczalnych w kontekście natrysku na nie pian poliuretanowych. Autorka powołuje się na badania przeprowadzone przez Krzysztofa Patokę.
EN
The article discusses the specificity of vapor permeable membranes in context spraying polyurethane foams on them. The author cites based on research conducted by Krzysztof Patoka.
Development and implementation of methods for cleaning the internal cavity of pipelines in the process of transporting fluids is important to ensure their energy efficiency and safe operation. The dynamics of the movement of one-piece cylindrical cleaning pistons made of various materials (silicone compound, self-destructive elastic polymer composition, polyurethane foam assembly foam) in the pipelines of pipeline systems intended for fluid transportation were studied by modelling and experimentally. The dynamics of movement of solid cylindrical cleaning pigs made from various materials (silicone compound, self-destructive elastic-polymer composition, polyurethane foam) in bends of pipeline systems intended for fluid transportation were studied through modelling and experiments. The analysis of forces acting on the pig during its movement in the pipeline bend was conducted, and the equations of pig motion based on Newton's second law were formulated. Contact forces of normal reaction, arising due to pig bending in the pipeline bend and determining the magnitude of frictional force between the pig and the inner wall of the bend, were determined based on classical bending theory. The impact of the material's modulus of elasticity, from which the pig is made, on the magnitude of contact forces of normal reaction at the pig pressing points against the inner wall of the pipeline bend was established. A method for determining the conditions under which pigs made from different materials will pass through pipeline bends without stopping and getting stuck was proposed. An equation for calculating the minimum allowable pig movement speed at the entrance to the bend to ensure its passage without stopping and getting stuck was derived.
The study examined the influence of selected inorganic fillers (5 and 10% by mass) on the foaming process, physicochemical properties, and structure of self-extinguishing polyurethane foam (density of approx. 35 kg/m3) obtained by reacting polyol with isocyanate (100:110). The filler used was bentonite (B), lamellar graphite (G), dendritic copper (Cu), aluminum oxide (Al2O3) and silicon carbide (SiC) and Al2O3/SiC mixture (1:1). Stereoscopic microscopy was used to determine the structure. The functional properties were examined based on density, water absorption and fire resistance. The course of the foaming reaction depends on the content, type and physicochemical properties of the filler. The addition of bentonite increases water absorption and Al2O3 reduces flammability of the foam.
PL
W pracy zbadano wpływ wybranych napełniaczy nieorganicznych (5 i 10 % mas.) na proces spieniania, właściwości fizykochemiczne i strukturę samogasnącej pianki poliuretanowej (gęstość ok. 35 kg/m3), którą otrzymano w wyniku reakcji poliolu z izocyjanianem (100:110). Jako napełniacza użyto bentonitu (B), grafitu o budowie lamelarnej (G), miedzi o strukturze dendrytycznej (Cu), tlenku glinu (Al2O3) i węglika krzemu (SiC) oraz mieszaninę Al2O3/SiC (1:1). Do oceny struktury stosowano mikroskopię stereoskopową. Właściwości użytkowe oceniano na podstawie gęstości, absorpcji wody i odporności na ogień. Przebieg reakcji spieniania zależy od zawartości, rodzaju i właściwości fizykochemicznych napełniacza. Dodatek bentonitu zwiększa absorpcję wody, a Al2O3 zmniejsza palność pianki.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł pokazuje przykład termomodernizacji kamienicy wpisanej do rejestru zabytków, co wymusiło wybór odpowiedniego materiału oraz technologii wykonania izolacji. Materiał izolacyjny wybrano na podstawie obliczeń grubości potrzebnej do uzyskania współczynnika przenikania ciepła wymaganego w 2021 r. Sposób montażu określono na podstawie zdolności kapilarnych termoizolacji. W artykule policzono współczynniki przenikania ciepła kamienicy nieocieplonej i porównano z obliczonymi współczynnikami w przypadku różnych materiałów izolacyjnych przy założeniu obecnych wymagań termicznych.
EN
The article is a case study of thermomodernisation of a tenement house entered in the register of monuments, which forced the choice of insulation material and technology. The insulation material was chosen based on calculations of needed thickness to obtain the required heat transfer coefficient for 2021. The installation method was chosen based on the capillary capacity of the thermal insulation. In this paper, the heat transfer coefficients for an uninsulated tenement house were calculated and compared with the calculated coefficients for different insulation materials assuming current thermal requirements.
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Odpady pianki poliuretanowej pochodzące z produkcji wyrobów do izolacji cieplnej w budownictwie można poddawać recyklingowi na różne sposoby, ale wszystkie metody mają swoje zalety i wady. Z przeglądu literatury [1–10] wynika, że recykling fizyczny jest najbardziej pożądanym sposobem utylizacji. Zwraca się uwagę, że fizyczna metoda recyklingu, ze względu na prostą obsługę i stosunkowo aktywną aplikację, w krótkim czasie może okazać się skutecznym środkiem rozwiązującym problem odpadów stałych. Natomiast metoda recyklingu chemicznego, ze względu na większą trudność techniczną do poradzenia sobie z procesem chemicznym w dużej skali, wymaga dalszych prac doskonalących, ale w dłuższej perspektywie będzie to bardzo efektywna metoda odzyskiwania cennych surowców chemicznych.
EN
Polyurethane foam waste generated during the production of thermal insulation products in construction can be recycled in various ways, however there are advantages and disadvantages in all methods. The literature review shows that physical recycling is the most desirable method of disposal. It is noted that the physical method of recycling, due to its simple handling and relatively active application, in a short period of time may prove to be an effective means of solving the problem of solid waste. On the other hand, the chemical recycling method, due to the greater technical difficulty in dealing with a large-scale chemical process requires further improvement, but in the long run it will be a very effective method of recovering valuable chemical raw materials.
The possibility of using modular buildings for residential and public needs is considered. Due to the peculiarities of technology and the use of thermal insulation materials, such structures are erected in a short time with the help of ready-made modules, characterized by their simplicity and speed of installation. The results of the multi-criteria analysis are presented in the form of petal diagrams and diagrams of global priorities.
An innovative method of insulation by injection to a cooling tank was investigated with consideration of a sustainable development need during production of thermo-insulation materials. An insulation material consisted of polyurethane foam. The manufacturer has chosen HFO gases for filling in the pores, since this is a product with a low environmental impact. HFO gases have a zero potential for destruction of the ozone layer and an extremely low global warming potential. Cooling tanks insulated with modern technologies of injection of polyurethane foam were investigated with regard to heat permission. They were also tested on account of occurrence of heat leakage bridges. The investigation covered also cooling furniture insulated with a conventional method of gluing ready-made polyurethane boards. The tests showed that a modern insulation technology influences reduction of the heat permission coefficient towards the presently applied technology. The investigated insulation of cooling furniture did not prove any heat leakage bridges. Therefore, it may be concluded that the technological process is correct. Cooling tanks manufactured in the present insulation technology did not show the occurrence of heat leakage bridges.
PL
Uwzględniając potrzeby zrównoważonego rozwoju podczas produkcji materiałów termoizolacyjnych, przebadana została innowacyjna metoda wtryskiwania materiału izolacyjnego do wnętrza wanny chłodniczej. Jako materiał izolacyjny wybrana została pianka poliuretanowa. Jako substancje odpowiedzialne za wypełnienie porów producent wybrał gazy z grupy fluoro-olefin (HFO), zatem produkt charakteryzujący się niewielkim wpływem na środowisko naturalne. Gazy z grupy fluoro-olefin (HFO) posiadają zerowy potencjał niszczenia warstwy ozonowej oraz bardzo niski potencjał globalnego ocieplenia. Wanny chłodnicze zaizolowane przy użyciu nowoczesnej technologii wtryskiwania piany poliuretanowej, przebadane zostały pod kątem współczynnika przenikania ciepła. Zostały także ocenione pod kątem występowania mostków cieplnych. Badaniom poddano także meble chłodnicze zaizolowane tradycyjną metoda wklejania gotowych płyt poliuretanowych. Przeprowadzone testy wykazały, że nowoczesna technologia izolowania wpływa na obniżenie współczynnika przenikania ciepła względem obecnie stosowanej technologii. Przebadana izolacja mebli chłodniczych nie wykazała występowania żadnych mostków cieplnych, zatem można wnioskować, że proces technologiczny jest prowadzony w prawidłowy sposób. Wanny chłodnicze wykonane w obecnej technologii izolowania także nie wykazały występowania mostków cieplnych.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono analizę czterech typów pomostów pływających. Trzy z nich są ogólnie dostępne na rynku, natomiast rozwiązanie czwarte stanowi projekt autorski. Komfortowe użytkowanie pomostu związane jest z wyborem właściwego rozwiązania zależnie od panujących warunków i potrzeb użytkownika. W tabeli przedstawiono wszystkie konstrukcje tak, aby potencjalny nabywca z łatwością mógł dobrać najodpowiedniejsze rozwiązanie.
EN
The article presents an analysis of four types of floating platforms. Three of them are generally available on the market, while the fourth solution is an original project. Comfortable use of the platform is connected with the selection of the right solution depending on the prevailing conditions and the user's needs. In table all constructions were collected so that a potential buyer could easily choose the most suitable solution.
13
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Dookoła nas coraz więcej przedmiotów składa się z materiałów polimerowych. Ich właściwości podwyższają komfort codziennego życia. Niestety ze względu na swoją budowę są wspaniałymi paliwami. W artykule omówiono budowę pianek poliuretanowych wraz z opisem procesu ich gaszenia. Opisano przeprowadzone dwa badania polegające na gaszeniu próbek z pianki poliuretanowej dyszą mgłową spiralną i tradycyjnym tryskaczem. Artykuł zawiera także opis badań wykonanych przez innych badaczy oraz wnioski z przeprowadzonych badań własnych.
EN
Around us, more and more objects are made of polymeric materials. Their properties increase the comfort of everyday life. Unfortunately, due to their structure, they are great fuels. This article presents the structure of polyurethane foams with a description of extinguishing them. The article describes two tests carried out, consisting in extinguishing polyurethane foam samples with a spiral water mist nozzle and the traditional sprinkler. The article also contains a description of research carried out by other researchers and conclusions from the own research.
Firstly, the paper focused on the polyurethane foam soaking process with pyrrole solution, and discuss the estimated electro-mechanical properties of the modified PU foam. Secondly, scanning electron microscopy (SEM) micrographs were collected to understand the polypyrrole distribution inside the foam. The results show that the chemical polymerisation parameters needed to realise this amount of polypyrrole in the foam were 0.1 mol/L of pyrrole, a mole ratio of 1:2.25, an oxidation temperature of 12 ± 3 °C, and an oxidation time of 2 hours. SEM images of the samples prepared with the modified approach showed a continuous layer of about 10-15 μm thickness of the polypyrrole attached to the surface of the PU foam.
PL
W artykule skoncentrowano się na procesie namaczania pianki poliuretanowej roztworem pirolu i omówiono oszacowane właściwości elektromechaniczne zmodyfikowanej pianki PU. Następnie zbadano rozkład polipirolu wewnątrz pianki przy zastosowaniu skaningowego mikroskopu elektronowego (SEM). Wyniki pokazały, że parametry polimeryzacji chemicznej potrzebne do uzyskania odpowiedniej ilości polipirolu w piance wynosiły 0,1 mol/l pirolu, stosunek molowy wynosił 1:2,25, temperatura utleniania wynosiła 12 ± 3 ° C i czas utleniania 2 godziny. Obrazy SEM próbek przygotowanych zgodnie ze zmodyfikowanym podejściem pokazały ciągłą warstwę o grubości około 10-15 μm polipirolu na powierzchni pianki PU.
Pokrycia dachowe głównych budynków elektrowni narażone są na różne niekorzystne oddziaływania mechaniczne i termiczne. W wielu przypadkach pokrycia te ulegają dość szybkiemu zużyciu lub różnorodnym uszkodzeniom. W pracy zaprezentowano niektóre przypadki uszkodzeń dachowych pokryć papowych oraz pokryć z pianki poliuretanowej (PUR) w budynkach kotłowni i maszynowni oraz w innych budynkach. Szczególną uwagę zwrócono na dużą wrażliwość pokryć z pianki PUR na czynniki mechaniczne i termiczne. Wskazano na potrzebę badań odporności pianek poliuretanowych na specyficzne czynniki występujące w dachach budynków elektrowni.
EN
Roof coverings of the main power plant buildings are exposed to various adverse mechanical and thermal impacts. In many cases, these coverings wear out quite quickly or are damaged in various ways. The paper presents some cases of damage of tar paper coverings and polyurethane (PUR) foam coverings in boiler room and engine room buildings and other buildings. Special attention was paid to high sensitivity of PUR foam coverings to mechanical and thermal factotors. The need to test the resistance of polyurethane foams to specific factors occurring in the roofs of power plant buildings was indicated.
Following paper is focused on experimental and numerical studies of the behavior and energy absorption for both: quasi-static and dynamic axial crushing of thin-walled cylindrical tubes filled with foam. The experiments were conducted on single walled and double walled tubes. Unfilled profiles were compared with tubes filled with various density polyurethane foam. All experiments were done in order to possibility of the safety of the elements absorbing collision energy which can applied in car body. The dynamic nonlinear simulations were carried out by means of PAM-CRASH™ explicit code, which is dedicated calculation package to modelling of crush. Computational crushing force, plastic hinges locations and specimens post-crushed geometry found tobe convergent with the real experiments results. Conducted experiments allowed to draw conclusion, that crashworthiness ability is directly proportional to foam density. The investigation of the experimental data revealed, that double walled tubes have greater energy absorbing ability. A proposed investigation enable to analyze and chosen of optimal parameters of these elements, which can use in automotive industry as an absorption energy components.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Zaproponowano metodę oceny dynamiki procesu spieniania pianek polistyreno-uretanowych (PSUR) za pomocą pomiarów temperatury. W wyniku procesu spieniania otrzymano materiał kompozytowy oparty na sztywnej matrycy pianki poliuretanowej (PUR), która jako napełniacz zawierała termoplastyczne kulki z ekspandowanego polistyrenu (EPS). Stosując termopary, wykonano pomiary temperatury w funkcji czasu T(t) w sześciu punktach formy do spieniania pianek PSUR, w przedziale czasu od początku (t = 0) do końca procesu spieniania (t = tk). Zbadano wpływ zawartości napełniacza EPS na kształt profili temperatury T(t). Praca stanowi uzupełnienie przedstawionych wcześniej badań dynamiki procesu spieniania pianek PSUR z użyciem miernika gęstości strumienia ciepła1).
EN
Two types of bicomponent systems for the prodn. of rigid polyurethane foams (high- and low-reactive) were mixed with polystyrene beads (EPS) to obtain 2 polystyrene-polyurethane composites (PSUR). The mixts. were poured into metal mold at room temp. The effect of EPS mass fraction on the PSUR foaming process were examd. by using measurements of temp. and heat flux d. as a function of time. The expansion of EPS occurred already at 50°C in the low-reactive system.
Pianki poliuretanowe o różnym przeznaczeniu, stosowane do produkcji płyt izolacyjnych, typu PUR i PIR, otrzymywane metodą in situ w budynkach, były badane pod kątem emisji lotnych związków organicznych w komorach klimatyzowanych w temperaturze 23°C oraz w temperaturze podwyższonej w desorberze termicznym. Stwierdzono emisję par związków stosowanych do spieniania pianek, opóźniaczy palenia, pozostałości katalizatorów i środków pomocniczych.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule podano wyniki badań próbek murowych z autoklawizowanego betonu komórkowego (ABK) na zaprawie z piany poliuretanowej prowadzonych na Białorusi. Ustalono wytrzymałość muru na ściskanie, ścinanie i rozciąganie przy zginaniu. Porównano te wyniki z otrzymanymi podczas badań próbek na spoinach cementowo-polimerowych oraz z wynikami badań prowadzonych na Politechnice Śląskiej.
EN
The article presents the results of tests of masonry samples of autoclaved aerated concrete (AAC) on polyurethane mortar carried out in Belarus. Compressive strength, shear and tensile strength during bending of the masonry samples were determined. The test results were compared with sample tests on thin cement-polymer as well as with the research results conducted at the Silesian University of Technology.
The paper discusses the use of multiclustering statistical analysis in the assessment of domestic wastewater filtration effectiveness. Calculations included data collected over four months of experiments with using waste as filling material of vertical flow filters for domestic sewage treatment. The effectiveness of pollutants removal was analysed in case of mechanically shredded waste in the form of PET flakes, PUR foam trims, shredded rubber tires and wadding. The organic compounds (CODcr, BOD5) removal, suspend solids, biogens (as NH4 +, PO4 3– ions) and oxygen saturation changing compared with sand filling was analysed. Multiclustering statistical analysis allowed to divide pollutants removal efficiency of analysed materials into 3 clusters, depending on the hydraulic loading. The first group consisted in quality parameters of treated sewage: the highest reduction of BOD5 and NH4-N. It included the values of quality parameters and indicators for the filtrates obtained at the lowest hydraulic load from columns filled with 60 cm of rubber tires or sand. The second group comprised the results for fillings containing foam, PET and rubber tires (the other hydraulic loads). It featured the highest reduction of total suspended solids and PO4 3–. Removal of easily biodegradable organic compounds was at a similar level in both cluster groups. The filter filled with polyester waste (wadding), which was as effective as 30 cm layer of sand, and the filters filled with 60 cm of sand working at the highest hydraulic load. Third group showed the lowest values of parameters and indicators for analysed filtrates.
PL
W pracy omówiono wykorzystanie wieloklastrowej analizy statystycznej do oceny skuteczności filtracji ścieków bytowych. Obliczenia obejmowały dane zebrane w ciągu czterech miesięcy badań dotyczących wykorzystania odpadów jako materiału wypełniającego filtry z przepływem pionowym. Skuteczność usuwania zanieczyszczeń została przeanalizowana na przykładzie odpadów mechanicznie rozdrobnionych w postaci płatków PET, skrawków pianki PUR, rozdrobnionych opon gumowych i owaty. Analizowano związki organiczne (CODCr, BOD5), zawiesiny ogólne, biogeny (jako jony NH4 + i PO4 3–) oraz stopień nasycenia tlenem w przypadku filtracji z zastosowaniem do tego procesu wymienionych odpadów i porównano te wyniki z uzyskanymi w filtrach z wypełnieniem piaskowym. Wieloklastrowa analiza statystyczna dała podstawy do podziału skuteczności usuwania zanieczyszczeń przez materiały filtracyjne w zależności od obciążenia hydraulicznego na trzy grupy. Pierwsza z nich obejmowała parametry jakościowe oczyszczonych ścieków – największą redukcję BZT5 i N-NH4 +. Znalazły się w niej wartości parametrów jakościowych i wskaźników dla filtratów otrzymanych w warunkach najmniejszego obciążenia hydraulicznego z kolumn wypełnionych odpadami gumowymi oraz piaskiem o miąższości 60 cm. Druga grupa obejmowała wyniki odnoszące się do wypełnień zawierających piankę poliuretanową, PET i gumę (dla pozostałych obciążeń hydraulicznych). Grupa ta charakteryzowała się największą redukcją zawiesin ogólnych i PO4 3–. Usunięcie łatwo ulegających biodegradowalnych związków organicznych było na podobnym poziomie w obu grupach klastrów. Filtr wypełniony odpadami poliestrowymi (owatą) był tak samo skuteczny, jak filtry wypełnione 30-centymetrową warstwą piasku i filtry wypełnione piaskiem o miąższości 60 cm (w warunkach największego obciążenia hydraulicznego). W trzeciej grupie znalazły się najmniejsze wartości wszystkich analizowanych parametrów i wskaźników dla przedmiotowych filtratów.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.