Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 206

Liczba wyników na stronie
first rewind previous Strona / 11 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  temperature distribution
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 11 next fast forward last
EN
The paper presents an investigation of the possibility for initiation of initial conditions in a road pavement model for thermal analysis incorporating non-stationary heat transfer. The procedure requires performance of computations for a sufficiently long initiation period to obtain the initial temperature distribution that may serve as the basis for further heat transfer analyses. The main part of the article is devoted to presentation of a numerical experiment performed for four configurations of parameters in the heat transfer model in a multilayer system, representing road pavement. Each parameter configuration corresponds to a different pavement structure (two models of flexible pavements and two models of pavements with foam concrete base course). Calculations were performed for three different amplitudes of the sinusoidal function describing the change of temperature in time, which was defined as boundary condition in the pavement model. The numerical experiment was supplemented by calculations performed on a single chosen model parameter configuration, but adopting a boundary condition based on values registered by a sensor installed in real pavement. Analysis of the obtained results confirmed that the presented method of non-stationary heat transfer analysis enables initiation of the initial conditions in the heat equation.
PL
W pracy rozpatrzono możliwość inicjacji warunków początkowych w modelu do analizy termicznej nawierzchni drogowej w warunkach niestacjonarnego przepływu ciepła. Procedura wymaga przeprowadzenia obliczeń dla odpowiednio długiego czasu inicjacji do uzyskania początkowego rozkładu temperatury, który jest podstawą dalszych analiz przepływu energii cieplnej. Główną część pracy stanowi prezentacja eksperymentu numerycznego przeprowadzonego dla czterech konfiguracji wartości parametrów modelu przepływu energii cieplnej w ośrodku wielowarstwowym, jakim jest nawierzchnia. Każda konfiguracja parametrów odpowiada innej konstrukcji (dwa modele nawierzchni podatnej i dwa modele z warstwą z pianobetonu). Obliczenia przeprowadzono kolejno dla trzech różnych wartości amplitud sinusoidalnej funkcji zmiany temperatury w czasie, którą zdefiniowano jako warunek brzegowy w modelu nawierzchni. Uzupełnieniem eksperymentu numerycznego były obliczenia przeprowadzone dla jednej wybranej konfiguracji wartości parametrów modelu, w którym warunek brzegowy stanowiły wartości temperatury zarejestrowane czujnikiem wbudowanym w nawierzchnię. Na podstawie analizy uzyskanych wyników potwierdzono, że inicjacja warunków początkowych w równaniu przewodzenia ciepła jest możliwa w oparciu o analizę niestacjonarnego przepływu ciepła przedstawioną metodą.
PL
Przegrzewanie pomieszczeń ostatniej kondygnacji sprawia, że komfort cieplny nie jest zachowany. W krajach takich jak Polska, gdzie nie używa się powszechnie klimatyzacji, problem ten jest szczególnie widoczny. W celu jego dokładnego zbadania wykonano w okresie letnim pomiary temperatury w pomieszczeniach budynków mieszkalnych wybudowanych w technologii tradycyjnej. Badania te potwierdziły problem przegrzewania tych pomieszczeń, dlatego też analizowano rozkład temperatury w miesiącach letnich w pomieszczeniach poddasza i niższych kondygnacji. Przeprowadzono również pomiar temperatury oraz symulacje numeryczne w budynku testowym. Ponadto wykazano wpływ wskaźnika utrzymania ciepła na średnią, maksymalną i minimalną temperaturę w pomieszczeniach. Za pomocą symulacji w ESP-r pokazano wpływ wskaźnika utrzymania ciepła na rozrzut wyników, gdyż okazuje się, że im większa jest jego wartość, tym rozrzut temperatury w ciągu doby jest mniejszy.
EN
It is commonly known that thermal comfort in the rooms on top floors is interrelated with their overheating. In regions (such as Poland) where air conditioning is not widely used, this problem is particularly evident. In order to thoroughly examine it, temperature measurements were made in the summer period. The measurements were made in the living quarters of buildings constructed in a traditional technology. The tests carried out confirmed that the top-floor rooms were subject to overheating. Therefore, the analysis involved also temperature distribution during the summer months both for attic rooms and rooms on lower floors. Temperature measurement and numerical measurement were also carried out in the test building. Moreover, the impact of the heat retention rate on the average, maximum, and minimum room temperatures was determined. First of all, using the simulation in ESP-r, the impact of heat retention rate on the scatter of results was demonstrated, since it turns out that the higher the value of heat retention rate, the smaller the temperature spread during the day.
EN
This investigation deals with the effect of variable thermal conductivity in a micropolar thermoelastic medium without energy dissipation with cubic symmetry. The normal mode technique is employed for obtaining components of physical quantities such as displacement, stress, temperature distribution and microrotation.
EN
The present research article deals with the study of a boundary value problem of a one-dimensional semi-infinite hygro-thermoelastic rod of length l. The deformation of the rod is under consideration when the left boundary of the hygro-thermoelastic rod is subjected to a sudden heat source. The solutions of the considered variables are decomposed in terms of normal modes. Analytical expressions of displacement, moisture concentration, temperature field, and stresses are obtained and presented graphically for different periods. By studying the one-dimensional thermal shock problem for a semi-infinite hygrothermoelastic rod, the authors aim to gain insights into the fundamental behavior of materials subjected to rapid temperature changes and moisture effects.
EN
The article presents the influence of environmental conditions on the temperature distribution in a pipe-embedded wall. For this purpose, measurements were taken on a test stand, a concrete wall with thermoplastic pipes (with a thermally activated element) embedded inside it in its symmetry axis. The wall is insulated with polystyrene on both sides. Additionally, as a result of its closure in an insulated casing made of oriented strand board (OSB), 2 air zones were created on both sides of the wall. The concreted loop was connected to a cooling bath thermostat used to set the supply temperature in the pipes. In the case of air, its supply to the air zones was provided by ventilation ducts mounted to the housing. The tests consisted of two stages: stabilization of the temperature on the surface of the partition between the concrete and polystyrene layer and the reaction of the structure to a variable outside temperature when fresh outside air was supplied to one of the air zones. All measurements were performed for the following settings: 16°C, 18°C, 20°C and 22°C. It was noted that in order to achieve an even temperature on the wall surface, 24 hours were required from the moment the cooling bath thermostat was turned on. When outside air is supplied to one of the air zones, this partition is resistant to temperature fluctuations, and only after about 6 hours a temperature change of 0.1°C takes place for sensors located at the extreme measurement points and in the other air zone (without air inflow).
PL
W artykule przedstawiono wpływ warunków otoczenia na rozkład temperatury w ścianie z wbudowanymi przewodami. W tym celu wykonano pomiary na stanowisku badawczym, betonowej ścianie z przewodami tworzywowymi (z elementem aktywowanym termicznie) wbudowanymi wewnątrz niej w jej osi symetrii. Ściana ta została z obu stron zaizolowana styropianem. Dodatkowo w wyniku zamknięcia jej w zaizolowanej obudowie wykonanej z płyt OSB powstały dwie strefy powietrzne z obu stron ściany. Zabetonowana pętla została podłączona do ultratermostatu, służącego do nastawienia temperatury zasilania w przewodach. W przypadku powietrza jego dostarczenie do stref powietrznych zapewniały zamontowane do obudowy przewody wentylacyjne. Badania składały się z dwóch etapów: stabilizacji temperatury na powierzchni przegrody między warstwą betonu a styropianu oraz reakcji konstrukcji na zmienną temperaturę zewnętrzną podczas dostarczania do jednej ze stref powietrznych świeżego powietrza zewnętrznego. Wszystkie pomiary odbywały się dla nastaw: 16°C, 18°C, 20°C i 22°C. Zauważono, że w celu osiągnięcia wyrównanej temperatury na powierzchni ściany potrzeba 24 godzin od momentu włączenia ultratermostatu. W przypadku dostarczania powietrza zewnętrznego do jednej ze stref powietrznych, przegroda ta jest odporna na wahania temperatury i dopiero po około 6 godzinach następuje zmiana temperatury o 0,1°C dla czujników zlokalizowanych w skrajnych punktach pomiarowych oraz w drugiej strefie powietrznej (bez napływu powietrza).
7
EN
In the article, a comparative analysis of one-dimensional dynamic models describing Thermal Energy Storages is carried out. A model based on energy balance was compared with a model of conductivity and convection and with a convection model. For each of them, the effect of time on the temperature distribution in the tank was examined and temperature distributions in the tank obtained for the analysed models were compared. Also, the effect of the number of nodes (discretization intervals) on the shape of the stratification curve was studied and the impact of the flow rate of the supplied hot water on the stratification curve was examined.
PL
W artykule dokonano analizy porównawczej jednowymiarowych dynamicznych modeli opisujących Thermal Energy Storages. Porównywano model oparty na bilansie energii z modelem przewodzenia i konwekcji oraz modelem konwekcyjnym. Dla każdego modelu badano wpływ czasu na rozkład temperatury w zasobniku, porównywano rozkłady temperatury w zasobniku otrzymane dla analizowanych modeli a także badano wpływ liczby węzłów (przedziałów dyskretyzacji) na kształt krzywej stratyfikacji. Badano także wpływ natężenia przepływu dostarczanej wody gorącej na krzywą stratyfikacji.
EN
The paper presents a methodology of solving boundary problems with uncertainty parameters based on the use of interval perturbation numbers. This methodology allows for the analysis of very complex problems with different uncertain parameters. Fuzzy Boundary Element Method (FBEM) using ɛ-number will be called ɛ-Fuzzy Boundary Element Method (ɛ-FBEM). Detailed discussion of the problems of computing and applications will be presented on the example of the fuzzy boundary integral equation arising from the boundary problem for the potential problems with heterogeneous, fuzzy boundary conditions of Dirichlet and Neumann type, fuzzy internal sources, fuzzy boundary and fuzzy fundamental solution. The presented methodology can be used to solve various engineering problems (e.g. in civil engineering, power engineering and others) – e.g. to analyze the temperature distribution in structural elements or elements located in the vicinity of objects or devices. In the latter case the increased temperature may be a symptom of a severe failure (e.g. power transformer overload, overexcitation or a fault) which cannot be tolerated due to the threat to the object and to the entire power system. Proposed method maybe used for electrical equipment diagnosis and in consequence as a power system failure prevention. In this paper calculation methodology is illustrated on the example of an area bounded by a square, on the left boundary of which a certain temperature is set, while on the rest of the boundaries the conditions are equal to zero. A dedicated computer program allows for the calculation of both temperature and temperature derivative for any number of boundary elements using ɛ-FBEM.
EN
Thermochemical treatment processes are used to produce a surface layer of the workpiece with improved mechanical properties. One of the important parameters during the gas nitriding processes is the temperature of the surface. In thermochemical treatment processes, there is a problem in precisely determining the surface temperature of heat-treated massive components with complex geometries. This paper presents a simulation of the heating process of a die used to extrude aluminium profiles. The maximum temperature differences calculated in the die volume, on the surface and at the most mechanically stressed edge during the extrusion of the aluminum profiles were analysed. The heating of the die was simulated using commercial transient thermal analysis software. The numerical calculations of the die assumed a boundary condition in the form of the heat transfer coefficient obtained from experimental studies in a thermochemical treatment furnace and the solution of the nonstationary and non-linear inverse problem for the heat conduction equation in the cylinder. The die heating analysis was performed for various heating rates and fan settings. Major differences in the surface temperature and in the volume of the heated die were obtained. Possible ways to improve the productivity and control of thermochemical treatment processes were identified. The paper investigates the heating of a die, which is a massive component with complex geometry. This paper indicates a new way to develop methods for the control of thermochemical processing of massive components with complex geometries.
10
Content available remote Detekcja defektów cieplnych systemu ETICS w warunkach quasi-stacjonarnych
PL
W artykule przedstawiono wstępne wyniki badań rozkładu temperatury na powierzchni ściany zewnętrznej z imperfekcjami systemu ETICS, prowadzonych w quasi-stacjonarnych warunkach pomiarowych. Badania wykazały zmianę rozkładu temperatury w obrębie defektów cieplnych o zróżnicowanych szerokościach oraz nieznaczny wpływ występującej dyslokacji cieplnej. Uzyskane wyniki wskazują na konieczność prowadzenia dalszych pomiarów w warunkach rzeczywistych.
EN
The article presents preliminary results of tests of temperature distribution on the surface of an external wall with imperfections of the ETICS system, carried out in quasi-stationary measurement conditions. The research showed a change in the temperature distribution within thermal defects of different widths and a slight influence of the occurring thermal dislocation. The obtained results indicate the necessity to conduct further measurements in real conditions.
EN
Renovation of multi-family residentials, including mainly thermal renovation, which includes adding thermal insulation, contributes to the improvement of living conditions. Above all, it reduces the operating costs of renovated buildings by reducing the consumption of heat energy for central heating. This article discusses the impact of light wet thermal renovation on the temperature distribution in the vertical cross-section of the partition wall and the calculation value of the temperature on the inner surface of the partition wall, as well as on the reduction of thermal energy consumption in buildings. The subject of the research was residentials erected in the large-panel, large-block, and traditional technology between 1984 and 1994, managed by Łomża Housing Cooperative (ŁSM).
PL
W celu określenia wpływu wzajemnego połączenia zróżnicowanych izolacji cieplnych w systmie ETICS na stan ochrony cieplno-wilgotnościowej zrealizowano badania w skali laboratoryjnej.
EN
In order to determine the influence of the mutual connection of different thermal insulations in the ETICS system on the condition of thermal and humidity protection, laboratory scale tests were carried out.
EN
High power fibre lasers need to be cooled efficiently to avoid their thermal damage. Temperature distribution in fibre should be estimated during the fibre laser design process. The steady-state heat equation in a cylindrical geometry is solved to derive a practical formula for temperature radial distribution in multi-layered optical fibres with arbitrary number of the layers. The heat source is located in one or more cylindrical domains. The validity of the analytical formula is tested by comparison with static heat transfer simulations of typical application examples including octagonal double clad fibre, air-clad fibre, fibre with nonuniform, microstructured core. The accuracy sufficient for practical use is reported even for cases with not exactly cylindrical domains.
PL
W artykule przedstawiono wyniki obliczeń numerycznych ścian zewnętrznych ocieplonych styropianem z dodatkową barierą ogniową w postaci wełny mineralnej. Założono dwa rodzaje warstwy konstrukcyjnej, wykonanej w postaci monolitycznej żelbetowej i z bloczków z autoklawizowanego betonu komórkowego. W wyniku obliczeń otrzymano rozkłady temperatury w przekroju ściany, z wyznaczeniem charakterystycznych wartości w miejscach szczególnych. Dla przyjętych założeń wykazano nieznaczne zróżnicowanie temperatury na wewnętrznej powierzchni ściany oraz duże wartości czynnika temperaturowego fRsi.
EN
The article presents the results of numerical calculations of external walls insulated with polystyrene with an additional fire barrier in the form of mineral wool. Two types of construction layer were established, made of monolithic reinforced concrete and autoclaved aerated concrete blocks.As a result of the calculations, temperature distributions in the cross-section of the wall were obtained, with their characteristic values in specific places. For the assumptions made, a slight temperature variation on the inner surface of the wall and high values of the temperature factor fRsi were demonstrated.
PL
Przebadano wymienniki współprądowe i przeciwprądowe (odpowiednio WW, WP) typu rura w rurze o małej mocy w konfiguracji 1, 2. Konfiguracja 1 oznacza przepływ cieplejszego czynnika w rurze wewnętrznej oraz zimniejszego w rurze zewnętrznej, natomiast konfiguracja 2 - chłodniejszego w rurze wewnętrznej oraz cieplejszego w rurze zewnętrznej. Wyższe wartości doświadczalnego współczynnika przenikania ciepła k| zarówno dla WW i WP zaobserwowano w konfiguracji 2. W tej pracy, porównano doświadczalne wartości k| z wartościami obliczonymi przy pomocy wybranych metod z teorii podobieństwa. Największą liczbę zgodnych z eksperymentem wartości teoretycznych k|, w zakresie wszystkich przebadanych rodzajów wymienników i ich konfiguracji, uzyskano dla formuły Hausena. Współczynnik k| zawiera trzy składowe: człon opisujący wnikanie ciepła od cieplejszego czynnika roboczego do przepony, przewodzenie przez przeponę rozdzielającą oba czynniki oraz przejmowanie ciepła od przepony do czynnika chłodniejszego. Wielkość tego współczynnika decyduje o wydajności z 1 mb wymiennika rurowego i w ten sposób wraz z średnią różnicą temperatury czynników roboczych wpływa ona na wielkość powierzchni wymiany ciepła a tym samym na gabaryty całego wymiennika.
EN
Co-flow and counter-flow (WW, WP) heat exchangers of low-power tube-in-tube in configuration 1, 2 were tested. Configuration 1 meant the flow of the warmer medium in the inner pipe and colder in the outer pipe, while configuration 2 - the cooler medium in the inner pipe, warmer in the outer pipe. Higher values of the experimental heat transfer coefficient k|, both for WW and WP were observed in configuration 2. In this work, the experimental values of k| were compared with the values calculated with the use of selected theoretical methods. The largest number of theoretical values of k|, consistent with the experiment, for all rested types of exchangers and their configurations, were obtained for the Hausen formula. The coefficient k| includes three components: the element describing the heat transfer from the warmer working medium to the diaphragm, conduction through the diaphragm separating both factors and the transfer of heat from the diaphragm to the cooler medium. The size of this coefficient determines the capacity per 1 running meter of the tube exchanger and thus, together with the average temperature difference of the working media, it affects the heat exchange surface and thus the dimensions of the entire exchanger.
EN
The article presents a three-dimensional numerical analysis of heat and humidity parameters carried out for a living room in a multi-family building. The aim of the analysis was to compare alternative heating methods with the existing one. Two cases were included in the analysis: case I - the existing state, case II - the existing state with an additional panel heater. In order to verify the numerical analysis for case I, the temperature and relative humidity were measured. During the heating period, the thermal conditions in the room did not favor the comfort of users, especially in one part of the room. The study may be a tool for future research related to the implementation of the climatic conditions of rooms with similar structural and functional features.
EN
In ultralight aviation, a very important engine parameter is the power-to-weight ratio. On the one hand, there is a tendency to minimize the size and weight of engines, and on the other hand, there is a demand to achieve the highest possible power by using supercharging systems. Increasing power brings many benefits, but it also increases temperature in the exhaust system, posing a threat to delicate parts of the ultralight aircraft fuselage. Therefore, it is necessary to control temperature values in the engine exhaust system. This article presents the temperature distribution in the exhaust system of an aircraft engine by the example of a four-cylinder Rotax 912 engine with an electronic fuel injection system. The research was conducted in two stages: measurements were made first for the engine without a turbocharger with an original exhaust system and later for its modified version with an added turbocharger system. The paper presents a comparative analysis of exhaust gas temperatures measured at three points: 30, 180 and 1000 mm from the cylinder head. The tests were conducted for the same preset engine operating conditions at constant speed and manifold air pressure. It has been shown that the exhaust temperature in the exhaust manifold decreases with the distance from the cylinder head. The highest gradient, over three times higher than the gas temperature from 589.9 °C to 192.3 °C, occurred in the manifold with a turbocharger for 2603 RPM and 31 kPa of manifold air pressure. The introduction of turbocharging causes an increase in exhaust gas temperatures before the turbocharger by an average of 12%, with this increase being greater for operating points of higher inlet manifold pressure. Turbocharging also causes a significant decrease in exhaust gas temperatures behind the turbocharger and the silencer because the temperature drops there by an average of 25%.
PL
Zagadnienia thermal-managementu są istotne, zwłaszcza w urządzeniach charakteryzujących się znaczną gęstością mocy. Dzięki racjonalnej dystrybucji energii cieplnej możliwe jest, przede wszystkim, dotrzymanie odpowiednich warunków, gwarantujących długotrwałą i bezawaryjną pracę elementów elektronicznych. W niniejszej pracy analizie poddano konstrukcję układu termostatowania baterii sześciu ogniw litowo - jonowych, przeznaczoną do eksploatacji w niskich temperaturach otoczenia. Elementy te są wrażliwe na warunki cieplne, determinujące ich trwałość oraz niezawodność. Opracowany model numeryczny został wykorzystany do wyznaczenia rzeczywistych charakterystyk eksploatacyjnych pozwalających na określenie parametrów układu izolacyjnego oraz źródła ciepła, pozwalających na spełnienie temperaturowych parametrów pracy ogniw. Uzyskane wyniki skonfrontowano z badaniami modelu fizycznego.
EN
Thermal-Management issues seems to be very important, especially in addition to devices characterized by large value of power density. Basing on rational distribution of thermal energy, there is possible, most of all, to develop appropriate conditions that guarantee a long and failurefree utilization of electronic equipment. In the paper the model composed of six lithium-ion batteries intended for exploitation in low temperature regime was analyzed. Such batteries are especially sensitive for temperature that determinates their durability and reliability. So that, device composed of batteries was complemented of thermal insulation and resistance heater. Developed numerical model was used to determine a real exploitation characteristics that enable for determination of thermal insulation and heat source parameters to fulfill thermal requirements of Li-Ion batteries. Obtained results were compared to the results of physical model tests. The physical model was designed especially for the paper requirements.
19
Content available remote Simulations of electrical parameters in high current busbars
EN
The requirements for high-current circuits, contact systems, switchboards and electrical apparatuses differ from the typical requirements for devices with a low current load, not only because those are more complex, but also because new requirements arise due to the fact that the size of the designed devices and power systems is constantly growing, both their breadth and diversity.
PL
Wymagania stawiane wielkoprądowym torom, układom stykowym, rozdzielnicom i aparatom elektryczny, różnią się od typowych wymagań dla urządzeń o niewielkim obciążeniu prądowym nie tylko tym, że są trudniejsze, ale pojawiają się wymagania nowe wynikające z tego, że ustawicznie rośnie wielkość projektowanych urządzeń i systemów elektroenergetycznych, ich rozległość i różnorodność.
first rewind previous Strona / 11 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.